Range of stainless-steel braided EPDM lined flexible hose assemblies with EPDM seals, available with a variety of end connections, some of which include isolation valves (see model). For use with: Copper Pipes manufactured in accordance with BS EN 1057 Plastic PB pipes manufactured in accordance with BS 7291-2 Plastic PEX pipes manufactured in accordance with BS 7291-3 Maximum working pressure: 6.0 bar @ 65°C Maximum working pressure: 12.0 bar @ 20°C
Range of EPDM lined hoses with grey PVC outer layer. Maximum working pressure: 16 bar. Maximum working temperature: 60°C.
Nimbus Compact range of combination heat pump units with enamel lined tank and stainless-steel coil. Fitted with a magnesium anode, expansion vessel and T&P valve set at 7 bar & 95°C. supplied with an inlet control group consisting of a pressure reducing valve, strainer, pressure relief valve and single check valve, and a tundish. Max working pressure 6.0 Bar Max operating Temperature 80 °C
Unvented hot water cylinder for domestic hot water 180 litre and buffer vessel 70 litre comprised of stainless steel main body, a stainless steel buffer cylinder 7 bar max working pressure max operating temperature 90°C. The cylinder is fitted with a T & P valve and supplied with an inlet control group consisting of pressure reducing, a pre-set expansion relief and incorporates a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). Max working pressure 7.0 Bar. Max operating temperature 90°C.
Range of 2, 3, 4, 5, 6 and 7 port manifold assemblies with brass bodies incorporating spherical valves with lever type operating members. The port compression connections are for use with copper pipe to EN1057. Maximum working pressure 16.0 Bar. Maximum operating temperature 95.0°C
Range of automatic air venting valve with bronze bodies. The FTBRZAVW-12 models have a stainless-steel float and a maximum working pressure 12.0 bar. The FTBRZAVW-10 models have a plastic float and a maximum working pressure 10.0 bar. Maximum working pressure - FTBRZAVW-12 models: 12.0 bar, FTBRZAVW-10 models: 10.0 bar. Maximum operating temperature 85°C.
Range of air release valves with blue epoxy coated ductile iron bodies and EPDM seats. Maximum working pressure 16.0 bar
Non-metallic materials and components comply with BS6920 at 80°C
Range of air venting valves with blue epoxy coated ductile iron bodies and stainless steel float. Maximum working pressure: 16.0Bar Maximum operating temperature: 60°c
Concealed, wall mounted, manual shower blending valve incorporating a brass body (various finishes) with ceramic cartridge headwork with a single lever operating member. Maximum working pressure: 10.0 Bar. Maximum operating temperature: 60 °C.
Range of T type thermostatic blending valves with (brass bodies - chrome plated finishes). The inlets incorporate a stainless-steel strainer. ISO models incorporate a servicing valve on each inlet. For use with copper pipe (BS EN 1057). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of wall mounted concealed thermostatic blending valves, (brass bodies – various finishes). Model (TVT126001000xx) incorporates a quarter turn ceramic disc headwork. Model (TVS126003000xx) incorporates a two-way ceramic disc diverter headwork. Temperature is controlled independently via a thermostatic mixing cartridge that incorporates a manual override button. Both models incorporate approved check valve cartridges; however, the complete products have not been fully tested to demonstrate they provide backflow protection. Maximum working pressure 5.0 Bar or 10.0 Bar (see models). Maximum operating temperature 60°C.
Range of thermostatic bar shower mixers, incorporating a quarter turn ceramic disc headwork controlling the flow with a dome type of operating member. The temperature is controlled independently via a thermostatic mixing cartridge incorporating a manual override button. Inlets incorporate single check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models ZI SHXSMCT C & ZI SHXSMCTFF C are supplied with a shower hose, handset and a riser rail. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of concealed thermostatic shower mixers, (brass bodies - various finishes). The flow is controlled by either a quarter turn ceramic disc headwork (model HOX1000Rx) or a three-way manual diverter (2 on, 1 off position) (model HOX1500Rx) with a single lever operating member. The temperature is controlled independently via a thermostatic cartridge with a single lever operating member. The inlets incorporate approved single check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5 Bar. Maximum operating temperature 85°C.
Range of T-type blending valve with brass bodies and thermostatic cartridges. Compression models are for use with copper pipe manufactured to EN1057. Maximum working pressure 25.0 Bar. Maximum operating temperature 75°C.
Range of lugged or wafer butterfly valves with either lever or hand wheel operation and a blue epoxy coated ductile iron body. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of butterfly valves with blue epoxy coated ductile iron bodies and discs, and EPDM seals with a wheel type operating member. Maximum working pressure 16.0 Bar Maximum operating temperature 85.0°C
Non-metallic materials and components comply with BS6920 at 85°C
Range of lug, wafer or flanged (see models) butterfly valves with blue epoxy coated ductile iron bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of butterfly valves with an epoxy coated ductile iron body, stainless steel disc and single lever or handwheel operating members. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of concealed, 2-way manual diverter valves incorporating a brass body. To be installed with 59556 000070 IXMO installation unit. Maximum working pressure 10.0 Bar. Maximum operating temperature 70°C.
Range of below ground (screw down type) fire hydrants with coated cast iron bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Page 419 of 505
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.