Shower handset with plastic bodies (chrome plated). Maximum operating temperature 65°C.
Range of shower handsets (chromium plated) brass bodies and NBR O-rings. The inlets incorporate stainless-steel strainers and approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Open outlet use only. Maximum operating temperature 60ºC
A range of shower kits and hand showers incorporating metal bodies (chrome plated). Some models are supplied with sliding rails, wall elbows and shower hoses (see models). Maximum working temperature 60°C.
Range of overhead shower outlets with brass bodies in various finishes (See models) incorporating EPDM ‘O’-rings and seals. The inlet to the shower heads incorporate either a plastic steel sieve (26 031 xxx) or a stainless steel (26 032 xxx) has a stainless-steel sieve. The inlet for the shower head incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection (Model 26 031 xxx only). Maximum operating temperature 60°C.
Range of wall mounted shower outlets with a brass bodies (chrome plated). The outlet incorporates a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum operating temperature 60°C.
Range of overhead shower outlets incorporating metal bodies (various finishes) and flow regulator and strainer on the inlets. Maximum operating temperature 43°C.
Range of overhead shower outlets incorporating metal bodies (various finishes) and flow regulator and strainer on the inlets. Maximum operating temperature 43°C.
Range of shower kits, comprosing of shower handset, shower hose, riser rail and overhead shower outlet depending on kit. Inlets incorporate a flow regulator (models 1.1740.578 & 1740.155) Maximum operating temperature 60°C.
Range of overhead showers with brass and plastic bodies (various finishes - see models). The inlet incorporates a stainless-steel strainer and a plastic strainer. Products to be used with basic sets with brass bodies and EPDM O-rings. Open outlet use only
Non-metallic materials and components comply with BS6920 at 60°C
Range of filter type fixed ‘shower’ outlets and shower handsets with plastic bodies. Maximum operating temperature 45°C.
Range of showers handsets with plastic bodies (various finishes - see model). All models incorporate a stainless steel strainer, the EcoSmart models also incorporate a plastic flow regulator. Maximum operating temperature 60°C.
Range of shower handsets with brass bodies available in various styles and finishes. The inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of shower handsets, shower heads, shower kits (consisting of wall outlet with bracket, shower hose and shower handset) and a 90-degree wall outlet elbow all with brass bodies (various finishes - see model). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted shower head and arm (chromium plated brass) incorporating a NBR seal and TPE gasket. The inlet to the shower head from the shower arm incorporates a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working temperature 60°C.
Range of shower handsets and shower kits. Shower kits 2.1703.391, 2.1703.015 & 2.1703.016 incorporate a shower handset, shower hose and riser rail. Shower handset inlets incorporate a flow regulator. Maximum operating temperature 60°C.
Range of flow switches incorporating brass or stainless steel bodies. Maximum working pressure 25.0 bar. Maximum operating temperature 100°C.
Range of flow sensors with brass or plastic bodies. Flow sensor type series VTY10 (plastic body, G3/4): Maximum working pressure 10.0 bar. Maximum operating temperature 85°C. Flow sensor type series VTY10 (plastic body, Quickfasten OD 22.5mm): Maximum working pressure 10.0 bar. Maximum operating temperature 70°C. Flow sensor type series VTY10 (brass body, G1/2): Maximum working pressure 16.0 bar. Maximum operating temperature 90°C.
Range of drain taps incorporating brass bodies, EPDM seats and washers and a non-rising spindle headwork. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of drain taps incorporating brass bodies, EPDM seats and washers and a non-rising spindle headwork. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Pillar tap (chromium plated brass) , incorporating a quarter turn ceramic disc headwork with a single lever operating member. The spout outlet incorporates a stainless steel aerator and the product is supplied with a metal backnut. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Page 41 of 214
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.