Range of bidet spray kits, wall outlet and brackets with brass bodies (various finishes), bidet spray kits consist of a wall outlet bracket, double interlocking flexible hose and a handset with self-closing trigger mechanism. Maximum working pressure 5 Bar. Maximum operating temperature 60°C.
Range of shower handsets and overhead showers with plastic bodies incorporating EPDM ‘O’-rings and washers. The inlet of the overhead shower models can be supplied with either a washer or a combined washer and stainless-steel strainer. Maximum operating temperature 65°C.
Product Identification | Surface finish | Inlet Dimension | Max Wrk. Pressure | Max Op. Temp. | Marking | Marking Location | All metals in the water pathway are on the 4msi positive list | Headwork | Fixing Type | Spout Outlet | Includes |
---|---|---|---|---|---|---|---|---|---|---|---|
980505CPVR | Chrome | 1/2 BSP | bar | 65 °C | Bristan | Shower Rose | No | Not applicable | Not Applicable | Not Applicable |
Range of (chrome plated) plastic shower handsets, each supplied with five (optional) plastic flow regulators (x2 blue, light green, dark green and grey). Maximum operating temperature 60°C.
Range of overhead shower outlets (ABS plastic - various finishes), incorporating a stainless-steel strainer. Open outlet use only Maximum operating temperature 60.0°C.
Range of wall or ceiling mounted shower outlets with chromium plated bodies (or black body for 22123KF0) consisting of showers arms and shower head for installation with specific rough-in sets. Shower head bodies incorporate approved single check valve cartridges, however, the complete assemblies have not been tested to demonstrate it provides backflow protection. The 26.484 model rough-in set incorporates a plastic flow regulator on the inlet. Maximum working pressure: Open Outlet. Maximum operating temperature: 60°C.
Range of shower handsets with plastic bodies and various finishes. Maximum operating temperature 60 °C. Open outlet use only.
Range of overhead shower outlets with stainless steel bodies (various finishes). The inlet incorporates a stainless-steel filter and a plastic flow regulator. Maximum working temperature 45°C. Open outlet use only.
Range of ‘Y’-pattern strainers with a DZR brass body, stainless-steel strainer and PTFE gasket. Maximum operating pressure 20.0 bar. BS6920 85°C.
Wall mounted hose union taps with brass bodies, incorporating a rising spindle headwork with a ‘T’ type operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Page 397 of 413
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.