Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies incorporating brass bodies (various finishes) and quarter turn ceramic disc headworks with dome type or single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of three-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members and metal backnuts. The spout outlets incorporate a plastic aerator. The headwork is connected to the spout via interconnecting stainless steel braided, EPDM lined flexible hoses. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of wall mounted spout outlets (brass bodies - various plated) incorporating a plastic aerator. Maximum operating temperature: 60 °C
Deck mounted spout outlet with chromium plated brass body incorporating a plastic aerator. Maximum operating temperature 60°C.
Wall mounted spout outlet, (chromium plated brass body) incorporating a plastic aerator. Maximum operating temperature 60°C.
Range of Grohe ‘Atrio’ wall mounted spout outlets (brass bodies - various finishes), the outlet incorporates a plastic aerator. Maximum operating temperature: 60°C
The products incorporate two check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 3), a pressure reducing valve adjustable between 1.0 bar and 3.0 bar (but pre-set at 2.5 bar for 523.815 model and 1.4 bar for the 523.816 model). The product incorporates a push type valve which allows water to flow when operated until the required pressure is achieved. There is a drain port below the push valve piston chamber. Compression connections are for use with copper pipe (manufactured to EN 1057). Maximum supply pressure 10.0 bar. Maximum operating temperature 80°C.
Range of filter heads with plastic bodies. Models with threaded connections incorporate a non-return valve (not suitable for backflow protection). Maximum working pressure 8.0 bar. Cold water use only.
Range of press fittings (brass bodies - various finishes) with stainless steel press (Unipress MLCP ) collars and EPDM O-rings for use with “EA” range of PEX/AL/PEX multilayer pipe (for press fitting connections and compression for EHA adaptor fittings only) or copper pipe manufactured to EN1057 (compression connections). Maximum operating temperature: 95°C. Maximum operating pressure: 10 bar.
Range of copper solder ring fittings for use with EN 1057 copper tube. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Supreme range of fittings for use with PE pipes (manufactured to EN12201-2). Supplied with a plastic pipe support liner For above and below ground use. Maximum working pressure 16.0 bar. Cold water use only.
Range of stainless steel (SS316L) pressfit fittings with EPDM ‘O’-rings for use with stainless steel pipe (manufactured to EN10312). Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of copper crimped fittings with EPDM ‘O’-rings for use with copper pipe manufactured to EN1057. For above and below ground use. Maximum working pressure 16 Bar. Maximum operating temperature 99°C.
Range of copper end feed fittings for use with copper tube to EN 1057. For above and below ground use. Maximum working pressure: 6mm-54mm 16.0bar, 64mm-108mm 10.0bar. Maximum operating temperature 85°C
Range of water meters with plastic bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of electromagnetic water meters with stainless steel bodies and natural rubber liners. Maximum working pressure 10.0 Bar Maximum operating temperature 50.0°C
Range of in-line single jet water meters with brass bodies. Products incorporate plastic strainers. Maximum working pressure: 16.0 Bar. Maximum operating temperature: 85.0°C.
Range of ultrasonic water meters with brass bodies. The products incorporate a motorised butterfly valve on the outlet. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of in-line water meters with brass or plastic bodies. Models with a minimum length of 130mm and a maximum operating temperature of 50°C are supplied with an optional, non-return valve to be fitted by the installer (not suitable for backflow protection). Maximum working pressure 16.0 bar. The meters can be supplied with a maximum operating temperature of 50°C or 70°C.
Water meter manifold with a gunmetal body. The product incorporates a non-return valve (not suitable for backflow protection) and a spherical valve on the inlet. Maximum working pressure 16.0 bar. Cold water use only.
Page 357 of 427
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.