Range of CENTERSTORE AIR bubble top indirect and direct single coil unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 10.0 bar@90˚C. A safety kit (manifold) consisting of a single check valve assembly, verified by test (suitable for backflow prevention against fluid category 2), strainer, an expansion relief valve set at 8.0 bar and a pressure reducing valve set at 3.0 bar and a tundish is also provided. Alternative inlet control group and temperature and pressure relief valve added March 2023. Maximum working pressure: Secondary circuit: 7.5 bar. Primary circuit: 6.0 bar. Maximum operating temperature 65°C.
Range of indirect unvented indoor heat pump storage cylinders which consist of a heat pump which sits on top of the tank and heats the hot water via refrigeration pipes which then heats the cylinder by being externally mounted around the cylinder. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar @ 90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve pre-set at 3.0 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum working pressure 6.0 Bar (Secondary) Maximum operating temperature 55.0°C
Range of wholesome-water nickel plated brass manifolds for use with ‘Emmeti Gerpex RA’ Pexb/Al/Pexb Multilayer pipe and ‘Emmeti Alpert’ PERT/AL/PERT Multilayer Pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C. Range of closed circuit use nickel plated brass manifolds for use with ‘JG Speedfit Layflat Polybutylene Barrier Pipe (models 10BPB & 15BPB)’. Maximum working pressure 3.0 bar. Maximum operating temperature 92°C.
Wall mounted thermostatic shower valve (chromium plated brass bodies), incorporating a quarter turn ceramic disc headwork diverting the flow between overhead shower and handset with cube type operating member. Temperature is controlled independently via a thermostatic cartridge with a cube type operating member that incorporates a manual override button. The product incorporates a fixed riser and overhead shower and is supplied with a shower hose and handset. Both inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete products have not been fully tested to demonstrate that they provide backflow protection. Maximum working pressure: 5.0 Bar Maximum operating temperature: 60°C.
Range of wall mounted, concealed, thermostatic shower valves with cast brass bodies, incorporating a ceramic cartridge headwork controlling the flow with a single lever operating member. The temperature is controlled independently via a thermostatic cartridge with a single lever operating member. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted thermostatic shower valve (chromium plated brass bodies), incorporating a quarter turn ceramic disc headwork diverting the flow between overhead shower and handset with dome type operating member. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member that incorporates a manual override button. The product incorporates a fixed riser and overhead shower and is supplied with a shower hose and handset. Both inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete products have not been fully tested to demonstrate that they provide backflow protection. Maximum working pressure: 5.0 Bar Maximum operating temperature: 60°C.
Wall mounted, exposed, thermostatic shower mixing valve (chromium plated brass). The product incorporate a ¼ turn ceramic disc or a 2-way ceramic disc diverter headwork (see model). Temperature is controlled independently via a thermostatic cartridge with a manual override button. The product has a dome type operating member. Each inlet incorporates a combined EPDM washer and stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, thermostatic shower valves with brass bodies (various finishes), incorporating a thermostatic cartridge controlling the temperature and a push shut-off valve controlling the flow. The inlets and the shower outlet incorporate approved check valve cartridges, however, the complete products have not been fully tested to demonstrate they provide backflow protection. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Range of wall mounted, thermostatic shower valves with brass bodies (various finishes). Flow is controlled with a ceramic disc headwork with a single lever operating member. Temperature is controlled independently by a thermostatic cartridge with a single lever operating member with a manual override button. Each inlet incorporates a stainless steel strainer and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of thermostatic shower panels incorporating a single sequential thermostatic control valve with a single lever operating member and flexible riser kit. Each inlet supplied with a servicing valve, EPDM o-ring and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Products are supplied with black lined PVC shower hoses and chrome plated shower handsets. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of wafer and lug type butterfly valves incorporating blue epoxy coated ductile iron bodies, either stainless steel (SS316/SS304) or epoxy coated ductile iron discs and EPDM seat. The valves are either handwheel and gear operated (Models SD-BVG16 and SD-16BVLL) or lever operated (Models SD-BVL125 and SD-16BVGL). Maximum working pressure 16.0 bar Maximum operating temperature 85°C.
Range of wall mounted concealed diverter valves with a plastic body. The flow is controlled to two outlets via solenoid valves. Maximum working pressure 5.0 Bar. Maximum working temperature 65°C
Range of concealed manual diverters (brass bodies) with chrome trim sets, model RAKPES3020-1C incorporating a dome type operating member and model RAKPER3020-1C incorporating a single lever operating member. Maximum working pressure – 5.0 Bar Maximum operating temperature - 85 °C
Range of pilot operated, adjustable, pressure reducing control valves, incorporating stainless steel bodies & strainers and EPDM ‘O’ rings & diaphragm. Auxiliary components include stainless steel tubing and isolation valves. The product is available with the following adjustable outlet pressures: 0 - 3.0 bar (silver spring), 1.0 - 8.0 bar (black spring), 1.0 - 16.0 bar (red spring). Maximum supply pressure 16.0 bar. Maximum operating temperature 65°C.
Range of spherical valves with nickel plated brass bodies, chromium plated brass balls, PTFE seals, NBR and/or FKM ‘O’-rings. 140, 140M, 141 & 141M series models incorporate a stainless-steel strainer. 140 & 141 series models also incorporate a magnet. The 121 & 122 series models are 3-way valves. Maximum working pressure: See PN in brackets under model. Maximum operating temperature: Cold water use only.
Range of spherical valves with nickel plated brass bodies, chromium plated brass balls, PTFE seals, NBR and/or FKM ‘O’-rings. 140, 140M, 141 & 141M series models incorporate a stainless-steel strainer. 140 & 141 series models also incorporate a magnet. The 121 & 122 series models are 3-way valves. Maximum working pressure: See PN in brackets under model. Maximum operating temperature: Cold water use only.
Resilient seated gate valves with blue epoxy coated ductile iron bodies, and an EPDM wedge, gasket and ‘O’-ring. With a non-rising spindle, and handwheel operating member. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of lock shield or handwheel operated gate valves with brass bodies, gate & PTFE seals, for use with copper tube manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of in-line screw-down stop valves with brass bodies, incorporating rising spindle headworks and EPDM washers. For use with BS EN 1057 copper pipe. Maximum working pressure 16 Bar at 30°C, 5 Bar at 99°C
Ultra violet disinfection units consisting of a stainless steel body and quartz sleeve. Model WS-10-1206/3030031 Alde Aquaclear has a maximum working pressure of 5.0 bar and a maximum operating temperature of 40°C. All other models have a maximum working pressure of 7.0 bar and a maximum operating temperature of 60°C.
Page 36 of 108
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.