Range of wall mounted, two-hole, single outlet, (fixed), combination tap assemblies (chromium plated brass bodies) incorporating ceramic cartridge headworks with single lever operating members and self-cancelling diverter to shower outlet. The spout outlet incorporate a plastic aerator. Maximum operating pressure 10 bar. Maximum operating temperature 60°C
Range of two-hole, single outlet (swivel) combination tap assemblies (brass bodies, various finishes - see model) incorporating a ceramic cartridge headwork with a dome type operating member. The spout outlet incorporates a plastic aerator. The headwork is connected to the spout via a stainless steel braided PEX lined flexible hose assembly. Maximum working pressure 10.0 bar. Maximum operating temperature 60.0°C
Range of deck mounted, three-hole, single outlet (fixed) combination tap assemblies (brass body - various finishes). The products incorporate 1/4 turn ceramic disc headworks with single lever, dome type, cubed or cross top operating members. The spout outlets incorporate plastic aerators. The products are supplied with stainless steel braided PEX lined flexible hose assemblies for connection between the side valves and the spout and click type pop-up wastes (verified by test). Maximum working pressure 3.5 Bar. Maximum operating temperature 60.0°C.
Three hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes), incorporating quarter turn ceramic disc headworks with cross top or lever type operating members. The spout outlets incorporate a plastic aerator. The products are supplied with stainless steel braided PEX lined flexible connecting hose assemblies, for use between side body valves and spout. Maximum working pressure - 10 Bar. Maximum operating temperature - 70°C.
Range of five-hole, single outlet (fixed) combination tap assemblies with a brass body, incorporating quarter turn ceramic disc headworks with single lever or cross top operating members. The products have a self-cancelling operated diverter to shower outlet and are supplied with a shower hose, shower handset and interconnecting braided hoses. The spout outlet incorporates a plastic flow aerator. Maximum working pressure 5 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (various finishes - see model). Electronic controls on the left-hand side of the body allow the tap to dispense one or more of the following (model specification dependent): boiling, chilled or sparkling water. Ambient (hot and cold) water is controlled via a ceramic cartridge headwork with a single lever operating member. The spout incorporates a plastic aerator on the Sparkling/Chilled and the Ambient outlet, and a separate outlet for the boiling water. Both model ranges incorporate a vent outlet within the tap spout for the boiling water circuit. Maximum working pressure 5.0 bar (Ambient (hot and cold) circuit only). 95458xxx models - Boiling circuit has a maximum operating temperature of 100°C. All other circuits have a maximum operating temperature of 65°C. 95459xxx models - Boiling circuit has a maximum operating temperature of 100°C. The ambient circuit has a maximum operating temperature of 65°C. The chilled/sparkling circuit has a maximum operating temperature of 60°C.
Zilmet range of cylindrical or tubular expansion vessels, epoxy coated carbon steel bodies with either Butyl or EPDM membranes and stainless-steel or galvanized carbon-steel connections. Please refer to models for maximum working pressures, as this varies by model and size. Maximum operating temperature 65°C.
Range of filling loop assemblies, consisting of: A nickel plated DZR brass bodied isolation valve with chrome plated DZR brass ball and integral non-verifiable double check valve assembly, verified by test (suitable for backflow protection against Fluid Category 3). A stainless-steel braided EPDM lined flexible hose assembly. An isolation valve with a nickel plated DZR brass body and a chrome plated DZR brass ball. The HLD14.12.049 model is supplied with a lanyard and cap end for each valve. The compression connections are for use with copper pipe (manufactured to BS2871). Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of filter cartridges. Maximum working pressure 8.0 Bar. Cold water use only.
Hep2O range of polybutylene fittings for use with Hep2O PB barrier pipe. In May 2024, Next generation (G5) of Hep20 pushfit fittings for use with the Hep20 range of PB barrier pipe, were added to the approval. Maximum working pressure 10.0 bar at 95°C.
Page 327 of 652
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.