Three hole, single outlet (fixed) combination tap assemblies with brass bodies (chrome plated), incorporating ceramic cartride headworks and single lever operating member. Spout outlet incorporates a plastic aerator. Product is supplied with a pop-up waste. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of three hole, single outlet (fixed) combination tap assemblies (brass bodies, various finishes) incorporating quarter turn ceramic disc headworks with single lever or dome type operating members. The spout outlet incorporates a plastic aerator. The product is supplied with copper tube for installation between the headworks and spout. Maximum working pressure 10 Bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of wall mounted, three-hole single outlet (fixed) bath and shower mixers with brass bodies (various finishes - see model), incorporating quarter turn ceramic disc headworks with cross top operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator. The shower outlet incorporates an approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The products are supplied with a shower hose and handset. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of single hole, two single outlets (swivel) combination tap assemblies (brass bodies - various finishes). Incorporating ceramic cartridge headwork, single lever operating member controlling both flow and temperature to the spout and spring-loaded pull-down hose. The pull-down hose incorporates a hand spray with a self-closing trigger mechanism. The spout incorporates a ceramic disc headwork controlling the flow with a single lever operating member. The spout outlets incorporate plastic aerators. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted tap assembly (chromium plated brass) incorporating a ¼ turn ceramic disc controlling the flow and a plastic aerator in the spout outlet. Maximum working pressure 10.0 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
A range of four hole single outlet fixed combination tap assemblies with chromium plated brass bodies, incorporating ceramic cartridge headworks controlling the flow with single lever operating members and a combined shut off/manual diverter cartridge with dome type operating members, which controls the flow as well as diverting the flow between the spout and the shower outlet. The diverter, side valve and spout are connected via stainless steel braided EDPM lined flexible hose assemblies incorporating ½” BSP connections. The spout outlets incorporate plastic aerators. Maximum working pressure 5 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of spout outlets with (brass bodies - various finishes), incorporating an plastic aerator. Maximum working pressure 10.0 Bar
Non-metallic materials and components comply with BS6920 at 60°C
Range of longitudinal (EFW) welded stainless steel (Grade 304/304L & 316/316L) pipes. Maximum working pressures: 1¼” sch 10: below ground = 55.0 bar. Above ground = 74.0 bar. 1½” sch 10: below ground = 48.0 bar. Above ground = 64.0 bar. 2” sch 10: below ground = 38.5 bar. Above ground = 51.0 bar. 2½” sch 10: below ground = 34.5 bar. Above ground = 46.0 bar. 3” sch 10: below ground = 28.0 bar. Above ground = 38.0 bar. 4” sch 10: below ground = 22.0 bar. Above ground = 29.0 bar. 5” sch 10: below ground = 19.5 bar. Above ground = 26.0 bar. 6” sch 10: below ground = 16.0 bar. Above ground = 22.0 bar. 8” sch 10: below ground = 14.0 bar. Above ground = 18.0 bar. ½” sch 40 & ¾” sch 40: below ground = 60.0 bar. Above ground = 80.0 bar. 1” sch 40: below ground = 30.0 bar. Above ground = 40.0 bar. 1¼” sch 40 & 1½” sch 40: below ground = 60.0 bar. Above ground = 80.0 bar. 2” sch 40: below ground = 54.5 bar. Above ground = 72.0 bar. 2½” sch 40: below ground = 60.0 bar. Above ground = 80.0 bar. 3” sch 40: below ground = 52.0 bar. Above ground = 69.0 bar. 4” sch 40: below ground = 44 bar. Above ground = 58.0 bar 5” sch 40: below ground = 38.5 bar. Above ground = 51.0 bar. 6” sch 40: below ground = 35.0 bar. Above ground = 46.0 bar. 8” sch 40: below ground = 31.0 bar. Above ground = 41.0 bar. Maximum operating temperature 100°C.
‘Super Speedfit’ range of plastic pushfit fittings (black, light grey, dark grey, white, natural, and red) for use with John Guest LLDPE tubing (blue, black, natural, green, orange, red, white and yellow). Operating parameters: 5/32”, ¼”, 5/16”, 4mm & 6mm = 16.0 bar cold water & 8.0 bar at 65°C. 3/8” = 10.0 bar cold water & 7.0 bar at 65°C. ½” = 10.0 bar cold water & 6.0 bar at 65°C. 8mm, 12mm & 15mm = 10.0bar cold water & 6.0 ba at 65°C. 10mm = 10.0bar cold water & 7.0 bar at 65°C.
“Super Speedfit” range of push-fit fittings with polypropylene bodies and EPDM or NBR ‘O’-rings (NC2301 model only) for use with John Guest LLDPE tubing (blue, black, natural, green, orange, red, white and yellow). Maximum working pressure and maximum operating temperature: 10bar @20°C, 4 bar @60°C.
Range of stainless steel (SUS304/316L) crimp fittings incorporating EPDM ‘O’-rings. For use with Mingshi stainless steel pipes (SUS304/316L). Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Primaflow ranges of brass, DZR brass, chromium plated brass, nickel plated brass and DZR brass compression fittings for use with copper pipe to BS EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
CB Ranges of brass, DZR brass, chromium plated brass, nickel plated brass and DZR brass compression fittings for use with copper pipe to BS EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Ranges of brass & chromium plated brass, nickel plated brass compression fittings for use with copper pipe to BS EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of ‘Superseal’ and ‘Speedfit’ push-fit fittings with acetal body’s (black or light grey) and NBR ‘O’ rings. For use with John Guest LLDPE tubing (Speedfit port only) and 316 stainless steel tubing manufactured to EN10088 (Superseal push-fit port only). Pipe inserts must be used for the LLDPE tube sizes 3/8” and ½”. Maximum working pressure: See models below. For cold water use only.
Range of press-fit fittings with stainless steel bodies incorporating EPDM ‘O’-rings for use with SS316L pipes. Maximum working pressure 16 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of plastic push-fit fittings (available in black, white and grey) and a manifold (available in grey only) with EPDM or NBR ‘O’-rings. For use with copper pipe (manufactured to EN1057), PE-X pipe (manufactured to BS7291-3:2010) & PB pipe (BS EN 21003-2:2008). Maximum working pressure: 12.5 bar @ 20°C (Cold water use only). From September 2023 the products are suitable for 8.0 bar @ 65°C.
Range of end feed copper fittings for use with copper tube to EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Hydraulic block incorporating a stainless steel and copper brazed plate heat exchanger, plastic fittings and adaptors, recirculation pump and a flow adjustment valve. Maximum operating temperature: Central Heating Circuit: 90°C, Direct Hot Water Circuit: 65°C. Maximum working pressure: Central Heating Circuit: 2.5 bar, Direct Hot Water Circuit: 10 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of air- or water-cooled commercial ice making machines with flow controlled via solenoid valve. Maximum working pressure 5 Bar
Non-metallic materials and components comply with BS6920 at 35°C
Page 33 of 113
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.