Range of four-hole, single outlet (fixed) combination tap assemblies (various finishes), incorporating quarter turn ceramic disc headworks with single lever or cross top operating members and a self-cancelling diverter to shower outlet. The spout outlets incorporate a plastic aerator. The products are supplied with a shower hose and the hose connector incorporates approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Not supplied with a shower handset. Maximum working pressure 5.0 bar Maximum operating temperature 60°C
Range of combined bath fillers and overflow waste assemblies with plastic bodies (various finishes). The outlet incorporates a plastic aerator and the product is supplied with a cable operated pop-up waste. Maximum operating temperature 60°C.
Range of free-standing sanitary macerating disposal units. The units are fed via a flexible hose assembly. Flow is controlled by a solenoid valve and discharges via a type `AA` air gap. Maximum working pressure 10.0 bar. Cold water use only.
Range of chemical dosing equipment which incorporate self-closing valves with a plastic body. The outlet of the injector incorporates a connection for injection of chemicals via venturi action. Maximum working pressure 9.0 bar. Maximum operating temperature – 60ºC
Easyzon range of chemical blenders, consisting of a reaction chamber and pressure reducing valve inlet arrangement only. Maximum working pressure 8.0 bar. Cold water use only.
Filling loop assembly, consisting of a stainless steel braided EPDM lined flexible hose, a lever operated brass spherical valve and a DZR brass double check valve assembly that incorporates a lever operated spherical valve. Maximum working pressure 10.0 bar. Maximum operating temperature 23°C.
Range of Aquaterra PP-RCT socket fusion fittings for use with Aquaterra PP-RCT SDR 6 pipe and Aquaterra PP-RCT SDR 7.4 pipe (manufactured to EN ISO 15874). Maximum working pressure 10.0 bar. Maximum working temperature 85°C.
Viega ‘Raxofix’ press connection fittings for use with viega Raxofix PE-Xc/Al/PE-Xc pipes. For above ground use only. Maximum working pressure 10 bar. Maximum operating temperature 70°C
Viega ‘Raxofix’ press connection fittings for use with viega Raxofix PE-RT/Al/PE-RT pipes. For above ground use only. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C
FloFit range of push fit fittings (polybutylene body) for use with Qual-Pex Barrier Pipe, Qual-PB polybutylene barrier pipe or copper tube. Above ground use only. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
‘Maincor’ range of pipe adaptors and ‘Multi-Fit’ straight connectors (brass bodies) for use with ‘Maincor PERT/Al/PERT MLC’ pipe. 12mm pipe and fittings have a maximum working pressure of 6.0 bar. 16mm & 20mm pipe and fittings have a maximum working pressure of 10.0 bar Maximum operating temperature 95°C
‘Numepress’ range of stainless-steel crimp fittings incorporating EPDM and ‘O’-rings. For use with stainless steel tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
‘Epsilon Series’ polypropylene bodied compression fittings with EPDM ‘O’-rings for use with Elysee PE80 blue pipes. The fittings are supplied with a pipe liner. Above and below ground use. Maximum working pressure 12.5 bar. Cold water use only.
Range of copper solder ring fittings for use with copper tube. For above ground use only. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Range of copper end feed fittings for use with copper tube. For above and below ground use. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Dual flush, WC outlet valves. Model A2706 is operated via a push button assembly for either full or reduced flush. Models A2415L & A2415M are not supplied with a operating button. Maximum operating temperature. Cold water use only.
Range of dual flush, WC outlet valves. The valves are operated via a push button assembly for either full or reduced flush. Cold water use only
Range of waste water heat recovery systems incorporating a twin wall copper coil (iZi models) or stainless steel (PiPe models). Maximum working pressure 10.0 bar. Cold water use only.
Range of indirect heat interface units with copper brazed stainless-steel heat exchangers, providing heating and instantaneous hot water. The products incorporate an expansion vessel on the cold-water supply to the plate heat exchanger and a safety relief valve on the space heating circuit set @ 3.0 bar. The domestic hot water and space heating circuit are both fitted with drain valves incorporating cover caps. Maximum working pressures: Domestic hot water 10.0 bar. Space Heating 2.5 bar. District Heating 3.0 bar. Maximum operating temperature 85˚C.
Range of gas fired water heaters incorporating stainless steel strainers on the inlets. Maximum working pressure 10.0 Bar Maximum working temperature 85˚C
Page 33 of 566
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.