Concealed WC dual flushing cistern with a vertical BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two push button assembly for a 6 or 3 litre flush volume. Maximum working pressure - 10 Bar Maximum operating temperature – Cold water use only.
Concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 3.5 litres. The cistern is operated by an electronically controlled flush valve. The product also incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 3.5 litres. The cistern is operated by an electronically controlled flush valve. The product also incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry BS 1212-4 compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Concealed WC dual flushing cistern with a bottom entry BS 1212 - 4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly for a 6 or 3 litre flush volume. Maximum working pressure 10.0 bar, cold water use only.
Concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by an electronically controlled flush valve. Maximum working pressure 10.0 bar. Cold water use only
WC flushing cistern incorporating a side entry BS 1212-4 compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by electronic or manual actuation. Maximum working pressure 10.0 bar. Cold water use only
Range of concealed WC dual flushing cisterns with a vertical BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly. The product also incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10 Bar, cold water use only.
Range of concealed WC dual flushing cisterns with a vertical BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly. The product also incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10 Bar, cold water use only.
WC flushing cistern incorporating a side entry BS 1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 3.5 litres. The cistern is operated by an electronically controlled flush valve. The product also incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only. .
Range of concealed WC dual flushing cisterns with a vertical BS 1212-4(2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two-push button assembly. The product also incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10 Bar, cold water use only.
Range of concealed cisterns incorporating a side entry float operated inlet valve providing a type AC air gap arrangement and a dual flush outlet valve. Maximum working pressure 10.0 Bar. Cold water use only.
BS EN 14055: 2018 concealed WC cistern incorporating a side entry compact type float operated inlet valve providing a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5) with a pneumatic or cable operated drop valve capable of full flush volumes of up to 6 litres and reduced flush of up to 4 litres. The cistern is operated by manual push button. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055 (2018) concealed WC cistern incorporating a side entry compact type float operated inlet valve discharging via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5) and a dual or single flush pneumatic or dual flush cable operated drop valve capable of full flush volumes of up to 6 litres with a reduced flush of up to 4 litres. The cistern is operated by manual push button/push plate. One of the side entry inlet valves is mounted internally and is supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055: 2018 concealed WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AB air gap and lever operated syphon capable of full flush volumes of up to 6 litres and reduced flush of up to 4 litres. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 997:2018 Roca Wall Hung W.C. pan (Ceramic), Thomas Dudley ‘A’ frame incorporating a Thomas Dudley Vantage Concealed cistern. The cistern incorporates a side entry compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern can be operated by a manual push button / push plate options. The inlet valve is mounted internally and supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 997:2018 Vitra wall hung W.C. pan (Ceramic), Thomas Dudley ‘A’ frame incorporating a Thomas Dudley Vantage Concealed cistern. The cistern incorporates a side entry compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of 3 litres. The cistern can be operated by manual a push button / push plate options. The inlet valve is mounted internally and supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve Maximum working pressure 10.0 bar. Cold water use only.
BS EN 997:2018 Vitra wall hung W.C. pan (Ceramic), Thomas Dudley ‘A’ or Illusion Compact Universal frame incorporating a Thomas Dudley Vantage Concealed cistern. The cistern incorporates a side entry compact type float operated inlet valve providing a Type AG air gap with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of 3 litres. The cistern can be operated by manual a push button / push plate options. The inlet valve is mounted internally and supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 997:2018 RAK Compact Rimless Wall Hung 700mm COMRIMWH W.C. pan (Ceramic), Thomas Dudley ‘A’ frame incorporating a Thomas Dudley Vantage Concealed cistern with a side entry compact type float operated inlet valve which discharges via a Type AG airgap and a dual flush pneumatic drop valve capable of full flush volumes of 4.5 litres and a reduced flush of 3 litres. The inlet connection hose incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
Undercounter boiling water cistern with a stainless steel body, stainless steel element and silicone ‘O’-rings and gaskets. Maximum working pressure 8.0 bar. Maximum operating temperature 95°C.
Undercounter boiling water cistern with a stainless steel body, stainless steel element and silicone ‘O’-rings and gaskets. Maximum working pressure 8.0 bar. Maximum operating temperature 95°C.
`PW` range of one-piece and two-piece GRP water storage cisterns and covers fitted with screened breather and supplied with a screened overflow. Cold water use only.
Purewater ‘PW’ range of GRP sectional storage cisterns and covers fitted with screened breather and supplied with a screened overflow. Cold water use only.
Range of one-piece and two-piece GRP water storage cisterns and covers fitted with screened breather and supplied with a screened overflow. Cold water use only.
Range of one-piece and two-piece GRP water storage cisterns and covers fitted with screened breather and supplied with a screened overflow. Cold water use only.
Range of one-piece and two-piece GRP water storage cisterns and covers fitted with screened breather and supplied with a screened overflow. Cold water use only.
Range of one-piece and two-piece GRP water storage cisterns and covers fitted with screened breather and supplied with a screened overflow. Cold water use only.
DAB range of one-piece and two-piece GRP water storage cisterns and covers fitted with screened breather and supplied with a screened overflow. Cold water use only.
Tanks Direct range of one-piece and two-piece GRP water storage cisterns and covers fitted with screened breather and supplied with a screened overflow. Cold water use only.
‘Precolor’ range of one piece, pre-insulated cold water storage cisterns and covers for domestic water storage, supplied with a wholesome water kit. The cisterns walls are available in grey, blue, green, white, red and anthracite grey (external) colours and the cistern base is straw coloured. For cold water use only. From November 2024 the water contact layer of the cistern base and walls is available in grey or straw colours. The outer layer of the cistern base is available in blue, green, white, red and anthracite grey colours.
Drayton GRP range of one piece, pre-insulated cold water storage cisterns and covers for domestic water storage, supplied with a wholesome water kit. The cisterns walls are available in grey, blue, green, white, red and anthracite grey (external) colours and the cistern base is straw coloured. For cold water use only. From November 2024 the water contact layer of the cistern base and walls is available in grey or straw colours. The outer layer of the cistern base is available in blue, green, white, red and anthracite grey colours.
Flowtech FS Range of GRP sectional storage cisterns and covers fitted with screened breather and supplied with a screened overflow. Cold water use only.
GRPBP range of one piece, pre-insulated cold water storage cisterns and covers for domestic water storage, supplied with a wholesome water kit. The cisterns walls are available in grey, blue, green, white, red and anthracite grey (external) colours and the cistern base is straw coloured. For cold water use only. From November 2024 the water contact layer of the cistern base and walls is available in grey or straw colours. The outer layer of the cistern base is available in blue, green, white, red and anthracite grey colours.
Range of GRP sectional cisterns with butyl seals, stainless steel bolts and an optional PVC-U flange connection. Cold water use only.
Sekisui F range of un-insulated GRP sectional cisterns. The larger cisterns have stainless steel internal bracing and UPVC pole supports. Insulated cisterns were added to the approval in March 2025. All cisterns are for cold water use only.
Press (TH press profile) and screw/compression fittings with brass bodies for use with Comisa Evo Pipe (PE-RT/AL/PE), for above ground use only. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Dudley Quantum single flush push button WC syphon. The syphon is operated via a top mounted cistern push button. For cold water use only.
Dudley Cascade Plus dual flush WC syphon flushing apparatus with a plastic body and stainless-steel link for use with WC flushing cisterns.
Dual flush WC syphon, with a polypropylene body and stainless-steel link for use with WC flushing cisterns. Cold water use only.
Range of combined storage and booster sets, incorporating a cold-water storage cistern, submersible pump, solenoid valve or alternative actuated ball valve, non-return valve (not suitable for backflow protection), isolation valves and expansion vessel. Maximum working pressure 10.0 bar. Cold water use only.
Range of side or bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow regulator. Maximum working pressure 10.0 bar. Cold water use only.
Range of side or bottom entry BS1212-4 (2016) compact type float operated valve for WC flushing cisterns. The inlet incorporates a flow regulator. Maximum working pressure 10.0 bar. Cold water use only.
Range of bottom and side entry BS1212-4 (2016) compact type float operated valves for WC flushing cisterns, delayed or non-delayed fill. The inlet incorporates a strainer. Maximum working pressure - 10 Bar Cold water use only.
Range of BS1212-4 (2016) compact type float operated valves for WC flushing cisterns, bottom or side entry type with brass ½’’ or ¾” BSP inlet. The inlet incorporates a strainer, models incorporate a delay fill function. The bottom entry valves are height adjustable. Maximum working pressure - 10 Bar, Cold water use only.
Side entry BS1212-4 (2016) compact type float operated valves for use with WC flushing cisterns. The inlet incorporates a strainer. Maximum working pressure 10.0 bar. Cold water use only.
BS1212-4 (2016) compact type float operated valve for WC flushing cisterns, side entry type. The inlet incorporates a plastic flow restrictor. Maximum working pressure 10.0 bar. Cold water use only.
Bottom entry A1370A and side entry A1423B BS1212-4 (2016) compact type float operated valves for WC flushing cisterns. The inlet incorporates a strainer. A1270A - plastic or brass connector. A1423B - plastic connector only. Maximum working pressure 10.0 bar. Cold water use only.
Bottom entry BS1212-4 (2016) compact type float operated valves for use with WC flushing cisterns. The inlet incorporates a strainer. Maximum working pressure 10.0 bar. Cold water use only.
Page 4 of 5
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.