Range of magnetic drive volumetric rotary vane pumps with a plastic housing and built-in relief valve. Maximum working pressure: 22 series models - 20.0 bar, 20 series models - 14.0 bar. Cold water use only.
Range of multistage centrifugal pumps with stainless steel bodies and impellers, and EPDM ‘O’-rings. Maximum operating pressure 11.0 bar. Maximum working temperature 90°C.
Range of pump units with plastic bodies and impellers, EPDM ‘O’-rings, expansion vessel with an EPDM membrane and a carbon graphite/ceramic/NBR shaft seal (bt-ar 13 bx 4ff xp). Each pump inlet incorporates a non-return valve. Single versions are standalone pumps, twin versions also include stainless steel manifolds. Maximum working pressure 10.0 bar. Cold water use only.
Range of horizontal self-priming multistage pumps with stainless steel bodies, stainless steel impellers, shaft and outer sleeve. Maximum working pressure 10.0 Bar Maximum operating temperatures: EH Three phase models 85°C, EH Single phase models 55.0°C and EHsp models 35°C.
Range of self-priming pumps with stainless steel bodies and impellers, and EPDM ‘O’-rings. Maximum working pressure 7.0 bar. Cold water use only. From November 2021 maximum operating temperature 60°C
Range of single stage end suction pumps with stainless steel or cast iron pump housings, EPDM ‘O’-rings and wear rings available in low-lead bronze/brass or stainless steel. Cast iron models are coated in black cathodic paint (textured finish) or black epoxy (smooth finish). The pumps are available with carbon graphite/silicon carbide mechanical shaft seal. Impellors are available in cast iron with black cathodic paint, low-lead bronze or stainless steel. The pumps are available with fixed flange, as well as loose flange (model dependent). Maximum working pressure 10.0 or 16.0 bar depending on model. Maximum operating temperatures: Stainless steel and cast iron with (smooth) epoxy coating pumps 85°C. Cast iron pumps with (textured) cathodic paint coating are cold water use only.
Range of hand held shower outlets incorporating plastic bodies and over head showeroutlets incorporating brass bodies. Model 46127 includes a handset and hose with a single check valve fitted at the inlet and outlet to the shower hose (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). model 46154 includes a single check valve in the shower handset (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). Over head shower (model 46150) outlets have an adjustable elbow connection. Maximum operating temperature 60°C.
Range of shower outlets incorporating brass bodies (various finishes) and EPDM ‘O’-rings. Maximum operating temperature 65°C.
Range of shower arms and brackets with brass bodies (various finishes). Shower brackets incorporate single check valves cartridge, however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Maximum operating temperature 85°C.
Range of shower handsets incorporating chromium plated plastic or chromium plated brass bodies (see model). Inlets incorporate a plastic flow regulator. Maximum operating temperature 60°C.
Range of overhead shower outlets incorporating brass bodies (chrome plated) and EPDM gaskets. Inlets have stainless filters incorporated within a ball joint. Maximum operating temperature 85°C
Range of shower outlets with brass bodies (various finishes) incorporating NBR ‘O’-rings (280R/W model) or EPDM ‘O’-rings (286P/W model). The inlet of the 286P/W model incorporates a plastic flow regulator. Maximum operating temperature 60°C.
Range of wall mounted shower outlets (brass bodies), shower hoses and handsets available in various finishes (see model). The shower outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of inline ‘Y’- patterned strainers with brass bodies & stainless steel filters. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of bib taps incorporating either brass or DZR brass bodies. The inlet and the outlet of the tap incorporates approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of wall mounted hose union taps (brass, chrome plated brass or DZR brass body) incorporating a non-rising spindle headwork with a butterfly handle operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of wall mounted taps (chromium plated brass) incorporating non-rising spindle headworks with cross top operating members. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps (chromium plated brass) incorporating non rising spindle headworks and cross top operating members. The spout outlets incorporate a plastic flow straightener. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps (chromium plated brass) incorporating non rising spindle headworks and cross top operating members. The spout outlets incorporate a plastic flow straightener. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps with brass bodies (chrome plated), incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener or aerator. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating pressure 85°C.
Page 4 of 522
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.