Range of thermostatic shower panels incorporating a single sequential thermostatic control valve with a single lever operating member and flexible riser kit. Each inlet supplied with a servicing valve, EPDM o-ring and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Products are supplied with black lined PVC shower hoses and chrome plated shower handsets. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of wall mounted concealed thermostatic blending valves with plastic bodies (various finished face plates). The flow is controlled by a ceramic disc diverter headworks with a cube type operating members. The temperature is controlled by a thermostatic cartridge with dome type operating members incorporating a manual override button. Both inlets incorporate an approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Wall mounted thermostatic shower valve with brass body (various finishes), incorporating a ceramic disc diverter that controlling the flow with a cube type operating member. The temperature is controlled independently via a thermostatic cartridge with a cube type operating member incorporating a manual override button. Both inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of wall mounted concealed (BIV & BIR models) and exposed (EV model) thermostatic shower control valves. The bodies are cast brass (concealed versions) with a chromium plated trim set or chromium plated brass (exposed versions). Flow and temperature are controlled by a thermostatic cartridge with a single lever operating member. The inlets incorpoarate stainless steel strainers. Some models are supplied with a shower hose and handset or an overhead shower arm and shower head with flow regulator (see model section). The BIV model is also supplied with an angled wall outlet elbow. Maximum working pressure 5.0 bar. Maximum operating temperature 45°C.
Wall mounted, bar type, thermostatic shower mixer (chromium plated brass), incorporating a 2-way ceramic disc diverter headwork with a cube type operating member controlling the flow between each shower outlet. The temperature is controlled independently via a thermostatic cartridge with a cube type operating member incorporating a manual override button. Both inlets incorporate a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection The product is supplied with a shower hose (PVC), shower handset (chrome plated), riser rail and overhead shower (chrome plated). The overhead shower and the shower handset both incorporate a plastic flow regulator and a combined EPDM washer and stainless steel strainer on the inlet. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, concealed, thermostatic shower mixers with brass bodies, dome or cube operating members and a thermostatic cartridge controlling the temperature. Models D1001, LB091, LB092, LB093, LB094, LB095, D2002, LB096, LB097, LB098, LB099, LB100, D3001, LB101, LB102, LB103, LB104 & LB105 incorporate approved check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of wall mounted thermostatic blending valves with brass bodies (chrome plated), incorporating two way diverter valves controlling the flow with dome type operating members. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member. The inlets incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°.
Range of wall mounted thermostatic shower valves (various finishes) incorporating a quarter turn ceramic disc headworks with single lever type operating members. The temperature is controlled independently via a thermostatic cartridge with manual override and single lever type operating members. Both inlets incorporate approved single check valve cartridges (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection). Maximum working pressure 5.0 bar. Maximum operating temperature 85°C.
Range of gear or lever operated wafer, semi lugged or fully lugged butterfly valves with blue epoxy coated ductile iron bodies, stainless steel discs and EPDM seats. Maximum working pressure 16.0 bar. Maximum operating temperature 80°C.
Range of concealed manual diverters (brass bodies) with chrome trim sets, model RAKPES3020-1C incorporating a dome type operating member and model RAKPER3020-1C incorporating a single lever operating member. Maximum working pressure – 5.0 Bar Maximum operating temperature - 85 °C
Manually operated thermally actuated regulating valves with bronze bodies and EPDM O-rings. Flow is controlled by a rising spindle headwork. Maximum working pressure 16.0 bar. Maximum operating temperature 90°C.
Range of spring-loaded resilient trim, non-return valves with blue epoxy coated ductile iron bodies, stainless steel discs and EPDM seals. Maximum working pressure 16.0 bar. Maximum operating temperature 80°C.
Range of in-line adjustable pressure reducing valves with DZR brass bodies and NBR ‘O’-rings. The valve incorporates a test port. The outlet pressures range from 1.5 bar to 6.0 bar. Maximum supply pressure 25.0 bar. Cold water use only.
Pressure relief valve with a brass body and EPDM diaphragm, pre-set at 3.0 bar. Maximum operating temperature 90°C.
Bistable (latching - pulse controlled) or monostable (normally open) solenoid valve with a plastic body, EPDM diaphragm and ‘O’-rings. The products incorporates a stainless-steel filer on the inlet. From February 2024 the product may also be supplied with a plastic filter. Maximum working pressure 10.0 bar. Maximum operating temperature: Between October 2022 and January 2024 this product is suitable for hot water use only (70°C). From February 2024 to the end of October 2027 this product is suitable up to 70°C.
Range of spherical valves with brass (K65281, K65282, K65283, K65301, K65302, K65303, K65291, K65292, K65293, K65311, K65312 & K65313) or DZR brass (K64783, K64784, K64793, K64794, K64763, K64764, K64773, K64774) bodies (chrome plated, nickel plated or without plating - see model), chrome plated brass ball and a range of different operating members (see model). Compression connections are for use with copper pipe (manufactured to EN 1057). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of spherical valves with various operating members, brass bodies, brass balls, FKM ‘O’-rings or EPDM ‘O’-rings (S84W series only) and PTFE seats. Maximum working pressure 40.0 bar. Maximum operating temperature 85°C.
Range of resilient seated gate valves with blue epoxy coated ductile iron bodies, and an EPDM wedge, gasket and ‘O’-ring. The FGAXXXNYYRB231 model has a rising spindle, the FGAXXXNYYNB231 model has a non-rising spindle, both have a handwheel operating member. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of screw down valves with brass or DZR brass bodies, brass or DZR brass bonnets, EPDM washers and PTFE seats. Compression connection to be used with copper pipe manufactured to EN1057. Maximum working pressure 16 bar. Maximum operating temperature 85°C.
Ultra violet disinfection units consisting of a stainless steel body and quartz sleeve. Model WS-10-1206/3030031 Alde Aquaclear has a maximum working pressure of 5.0 bar and a maximum operating temperature of 40°C. All other models have a maximum working pressure of 7.0 bar and a maximum operating temperature of 60°C.
Page 203 of 582
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.