Back To Directory SectionsRange of temperature measurement devices with bronze bodies and EPDM o-rings. Maximum operating pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Permanent filling devices for primary heating and chilled water closed circuits in domestic and non-domestic premises. The mains and closed circuit system pressures are continuously checked by two pressure sensors and their differential monitored by microprocessors. If the mains pressure is adequate and there is a drop in system pressure, then the two solenoid valves operate to allow water into the system via the transfer chamber. At all other times the normally open solenoid valve drains the transfer chamber to waste, via tundish (meeting the requirements of an air gap to drain), and allowing air to be admitted via an automatic air vent to create an atmospheric disconnection across the transfer chamber. Stainless steel strainer on the inlet supply. Mikrofill 3: Maximum working pressure 5.0 Bar. Cold water use only. Mikrofill 3 Pro (72846): Maximum working pressure 9.0 Bar. Cold water use only.
Flow meter with stainless steel body. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
‘AQ tap’ water dispensing unit incorporating a brass solenoid and a flow sensor. The unit is operated using a smart card and credit system that allows the user to obtain a set amount of water. Maximum working pressure 3.0 bar. Cold water use only.
Conealed wall mounted installation set with a brass body. Maximum working pressure 10 bar. Maximum operating temperature 70°C
Magnetic non-return valve with a brass body and EPDM seals. Maximum working pressure 16.0 Bar. Cold water use only.
Range of pressure transmitters with stainless steel bodies. Maximum working pressures: Press.Tr.ISP40 model 25.0 bar, all other models 50.0 bar. Maximum operating temperature 90°C.
Range of hose assemblies. Models B0301-148036-000 & B0301-148038-000 comprise of a spherical valve, stainless-steel braided EPDM lined flexible hose and double check valve assembly (suitable for backflow protection against fluid category 3). Model B0301-148037-000 comprises of a double check valve assembly (suitable for backflow protection against fluid category 3), stainless-steel braided EPDM lined flexible hose and ‘T’ type spherical valve. Maximum working pressure 10.0 bar. Cold water use only.
Waste water heat recovery unit having with an internal copper tube which provides a double wall separation between the waste water and cold mains supply. Maximum working pressure 10 bar. Maximum operating temperature 50°C
Hydraulic circuit used to control the water path within the heating and sanitary boiler, with plastic body incorporating filter, flow regulator, plate heat exchanger and EPDM O-rings. Maximum working pressure 7.0 bar. Maximum operating temperature 85°C.
Range of flow sensors with or without brass bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 90°C.
Range of valves intended to be used as part of a filling loop. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of single and doubled sphered rubbered expansion bellows incorporating a variety of flanged end connections. Style 99 TUF also incorporates a threaded inlet connection. Maximum working pressure 16.0 Bar Model (99 SSHDC) Maximum working pressure 20.0 Bar Cold water use only.
Range of single and doubled sphered rubbered expansion bellows incorporating a variety of flanged end connections. Style 99 TUF also incorporates a threaded inlet connection. Maximum working pressure 16.0 Bar Model (99 SSHDC) Maximum working pressure 20.0 Bar Cold water use only.
Range of single and doubled sphered rubbered expansion bellows incorporating a variety of flanged end connections. Style UF1001 also incorporates a threaded inlet connection. Maximum working pressure 16.0 Bar. Cold water use only.
Range of single and doubled sphered rubbered expansion bellows incorporating a variety of flanged end connections. Maximum working pressure 16.0 Bar Cold water use only.
Range of single and doubled sphered rubbered expansion bellows incorporating a variety of flanged end connections. Maximum working pressure 16.0 Bar Cold water use only.
Threaded adapter with plastic body. Maximum working pressure 12.5 bar. Cold water use only.
Isolation valve, stainless-steel braided EPDM lined flexible hose assembly and a non-verifiable double check valve assembly, verified by test (suitable for backflow protection against fluid category 3). For use with copper pipe (manufactured to EN 1057). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of diffuser domes which are intended to be submerged into water.
Non-metallic materials and components comply with BS6920 at 30°C
‘Tanktronic‘ range of water level monitoring kits comprising of a main control unit, vent box and single or double stainless steel sensors. Open outlet use only. Maximum operating temperature 23°C
Range of DZR brass metering stations supplied with red and blue test points for upstream and downstream port identification. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Non-metallic materials and components comply with BS6920 at 85°C
Range of wall & floor mounted, two hole, single outlet combination tap assemblies with brass bodies incorporating ceramic cartridge headworks with single lever operating members. Spout incorporates a plastic aerator. Products also incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The products are supplied with shower hose and handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of flow sensors with plastic bodies and rotors. Maximum working pressure: 10 Bar. Maximum operating temperature: 80°C.
Range of EEICo brass threaded fittings. Maximum working pressure 20.0 bar. Maximum operating temperature 60°C.
Range of stainless steel bodied mechanical pump shaft seals. The 491 model comprises of carbon and silicone carbide seal faces and EPDM ‘O’-rings. The 1510 model comprises of carbon and silicone carbide seal faces, EPDM ‘O’-rings and an orange NBR/aramid fibre gasket. Maximum operating temperature 100°C.
Range of self-acting controllers with brass bodies, EPDM O rings and gaskets. Maximum working pressure 16.0 Bar Maximum operating temperature of the secondary circuit is 65˚C and the primary circuit is 99˚C
Range of flow-compensated (thermostatic) temperature controllers incorporating a brass body with EPDM ‘O’-rings and gaskets. The valves incorporate a non-rising spindle headwork for temperature regulation. Maximum working pressure 16.0 bar. Maximum operating temperature 65°C
Range of concealed rough-in sets with brass bodies, intended for use in conjunction with trim and finish sets. Maximum working pressure 10.0 Bar Maximum operating temperature 85.0°C
Range of submersible pressure sensors and hydrostatic transmitters (supplied in lengths up to 1000m). Cold water use only.
Arrangement of PVC-U pipe and fittings for use with the Orca System. Maximum working pressure 9.0 bar. Cold water use only.
Range of brass bodied differential angled bypass valves incorporating a spring-loaded adjustment facility. Maximum working pressure 10.0 bar. Maximum operating temperature 110°C.
Combined bath filler and overflow waste assembly with a plastic body (various finishes - see model). The product incorporates a click type pop-up waste. Maximum operating temperature 85°C.
Flow restriction valve with a brass body. Maximum working pressure 35.0 bar. Maximum operating temperature 85°C. For non-wholesome water use only.
Range of differential pressure sensors with stainless steel bodies. Maximum working pressure 16 Bar. Maximum operating temperature 85°C.
Water hammer arrestor with brass body and EPDM ‘O’ ring. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.



Range of tap outlets with chrome plated plastic bodies. Maximum operating temperature 85°C.
Water hammer arrestor with brass body and EPDM ‘O’ ring. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of VEGAPULS radar sensors for level measurement with plastic bodies. Cold water use only. Open outlet use only.
Range of ‘Thermowatt’ immersion heater elements incorporating brass or DZR heads with either a copper, stainless steel, alloy or titanium heating element and a black EPDM ‘O’-ring. Open outlet use only. Maximum operating temperature 99°C
`Prox’ and ‘Wave` ranges of sensor operated flow control devices incorporating a normally closed solenoid valve to control the flow and operated via an infra-red sensor. The inlet incorporates a stainless-steel strainer. Maximum working pressure 8 Bar Maximum operating temperature 65°C
Range of leak detection devices incorporating a DZR brass body and non-return valve (not intended for and not suitable for backflow protection). Models Stopleak 1 & Stopleak 2 incorporate a spherical valve. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall brackets (brass bodies – various finishes). Open outlet use only Maximum working temperature 85°C
Water hammer arrestor with brass body and EPDM ‘O’ ring. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Hydraulic circuit used to control the water path within the heating and sanitary boiler, with plastic body incorporating filter, flow regulator, plate heat exchanger and EPDM O-rings. Maximum working pressure 7.0 bar. Maximum operating temperature 85°C.
Manifold with a brass body and 5 outlets. Maximum working pressure 15.0 bar. Maximum operating temperature 100°C.
Wall plate elbow with a brass body. Maximum operating temperature 100°C
Range of leak detection devices incorporating a DZR brass body and non-return valve (not intended for and not suitable for backflow protection). Models 3897590 & 3897690 incorporate a spherical valve. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Electroflo sensor operated flow control devices incorporating a normally closed solenoid valve to control the flow and operated via an infra-red sensor. The inlet incorporates a stainless-steel strainer. Maximum working pressure 8 Bar Maximum operating temperature 65°C
Range of test port assemblies with DZR brass bodies. Maximum working pressure 25.0 Bar. Maximum operating temperature 100°C.
Page 3 of 5
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.