Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes), incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of two hole, single outlet fixed combination tap assemblies, (brass bodies – various finishes) incorporating a push to open and push to close headwork. The spout outlet incorporates a plastic aerator and the product is supplied with a waste set not verified by test. Maximum operating pressure 10 bar. Maximum operating temperature 60°C
Range of wall mounted two-hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes). Incorporating a ceramic cartridge headworks and single lever operating member. The spout outlet incorporates an aerator. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of two hole, single outlet, fixed combination tap assemblies, (stainless steel bodies – various finishes) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet, fixed combination tap assemblies, (chrome plated brass bodies) incorporating a non-rising spindle headwork and a thermostatic cartridge that incorporates a manual override button both with either single lever or dome type operating members. The spout outlket incorporates a plastic flow straightener. The products are supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating ceramic disc headwork with single lever operating members and manually operated bath/shower diverter. The spout outlets of all models, except XB-SL-038T, incorporate a plastic aerator or flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature of model XB-SL-038T is 85°C. All other models have a maximum operating temperature of 65°C.
Range of two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating ceramic disc headwork with single lever operating members and manually operated bath/shower diverter. The spout outlet incorporates a flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Two-hole, single outlet (fixed) combination tap assembly (chromw plated brass body) incorporating quarter turn ceramic disc headworks with single lever operating members and a manually operated diverter to shower outlet. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts, shower hose and handset. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C
Range of two-hole, single outlet (swivel) combination tap assemblies with chromium plated brass bodies. Incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlets incorporate plastic aerators. Maximum working pressure 8.62 Bar. Maximum operating temperature 60.0°C.
Three hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating ceramic disc headwork with single lever operating members and a manually operated bath to shower diverter. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of three-hole, single outlet (fixed) combination tap assemblies (brass bodies – various finishes). Incorporating a ceramic cartridge headwork with a single lever operating member and self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator. The product is supplied with metal backnuts Maximum working pressure 10.0 Bar. Maximum operating temperature 60 °C
Range of single hole, double outlet (swivel) combination tap assemblies (various finishes) with electronically controlled functions to allow the tap to dispense boiling water, chilled water or sparkling water from under counter units (not supplied or part of this approval) and a ceramic cartridge headwork with single lever operating member controlling the flow of normal mixed water. The spout outlet incorporates a plastic aerator. Maximum working pressure: 5.0 Bar. Maximum operating temperature: 98.0°C.
Range of combined bath filler and/or waste and overflow assemblies (see models) in various finishes. Maximum operating temperature: 60ºC
Range of floor standing, single hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating a ceramic cartridge headwork with a single lever operating member and a manually operated diverter to a shower outlet. The spout outlet incorporates a plastic aerator. Model F9912-** incorporates a single check valve cartridge at the inlet, however, the whole product has not been fully tested to demonstrate that it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of wall mounted bath spout outlets with brass bodies (various finishes) with a plastic aerator incorporated into the outlet. Maximum working pressure: 5 bar. Maximum operating temperature 60°C
Range of wall mounted spout outlets (brass bodies - various finishes) incorporating a plastic aerator. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of shock arrestors comprising of a copper tube and brass adapter. Max working pressure 10.0 Bar. Max working temperature 80°C.
Shock arrestor with stainless steel body. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C
Range of carbon block water filters with stainless steel bodies. Maximum operating pressure 6.8 bar. Cold water use only.
Range of plastic pushfit fittings for use with ‘Bevex’ polypropylene pipe. Maximum working pressure 6.5bar. Cold water use only.
Range of “KFLEX SOLID” brass compression fittings, press profile H, TH, F and U, for use with “KFLEX SOLID” multilayers PE-RT/Al/PE-RT pipes. For above ground use only. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C
‘ZL’ range of U profile press fittings (nickel plated brass bodies) for use with ‘ZL’ range of PERT/AL/PERT multi-layered pipes. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
NovaTherm range of U profile press fittings (nickel plated brass bodies) for use with NovaTherm range of PERT/AL/PERT multi-layered pipes. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of copper solder ring fittings for use with EN 1057 copper tube. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of compression fittings with brass, nickel plated brass or DZR bodies for use with copper pipe (EN 1057). Above ground use only for use. Max working pressure 16 bar. Max operating temperature 85°C
FLOMASTA range of polypropolene fittings for use with PE pipe (manufactured to EN 12201). Maximum working pressure 16 bar. Cold water use.
Range of stainless steel press fittings: SS316L stainless steel models are for use with SS316L stainless steel pipe manufactured to EN 10312.; SS304 stainless steel models are for use with SS304 stainless steel pipe manufactured to EN 10312. Crimp joint is achieved by a M profile crimp jaws. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel press fittings (SUS304 or 316L) with EPDM ‘O’-rings for use with stainless-steel pipe (SUS304 or 316L EN 10312), using an ‘M’ press profile. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C.
Range of system 2000 of flange adaptors and connectors with ductile iron bodies (Blue Epoxy Coated) incorporating EPDM seals. For use with PE pipe manufactured to En 12201 & PVC Pipe manufactured to DIN 8062. Maximum working pressure: 16.0Bar Cold water use only.
Dual flush, WC outlet valve. The valve is operated via a push button assembly for either full or reduced flush and incorporates an internal overflow.
Indirect heat interface unit with copper brazed, stainless-steel heat exchangers, providing heating and instantaneous hot water. The product incorporates an expansion vessel on the cold-water supply to the plate heat exchanger and a safety relief valve on the heating circuit set @ 2.5 bar. The DHW and heating circuits are both fitted with drain valves incorporating cover caps. Maximum working pressure 16 Bar (Primary), 10 Bar (DHW) & 3 Bar (Heating) Maximum operating temperature 95°C
Tudor range of above and under sink range of electrically heated vented water heaters (cased and insulated) incorporating an angle valve on the inlet for flow control. Maximum working pressure 3.5 bar. Maximum operating temperature 75°C.
Range of in-line water meters with brass bodies and plastic turbines. The inlets incorporate plastic filters, and the outlets incorporate non-return valves (not suitable for backflow protection). Maximum working pressure 16.0 Bar. Maximum operating temperature 65.0°C.
Range of water meters with brass bodies with plastic impellers. LXSZ models incorporate a spherical valve on the inlet. Maximum working pressure 16.0 Bar Maximum operating temperature 50.0°C
Range of water meters with cast iron bodies (blue epoxy coating). Maximum working pressure 16.0 Bar Maximum operating temperature 70.0°C
Range of water meters with blue epoxy coated cast iron bodies. Maximum working pressure 16.0 Bar Maximum operating temperature 65.0°C
Range of water meters with brass bodies, plastic turbines and plastic strainers on inlets. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of in-line water meters with composite bodies, TPE gasket and NBR ‘O’-ring(s). The products have an integral plastic filter. The inlet of the in-line models includes a non-return valve. Maximum working pressure 16.0 bar. Cold water use only.
Range of leak detection devices incorporating a DZR brass body and non-return valve (not intended for and not suitable for backflow protection). Models 3897590 & 3897690 incorporate a spherical valve. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Self-closing hand spray with a stainless-steel body. The inlet incorporates a flow regulator and an approved check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). Maximum working pressure 5 bar. Max operating temperature 60°C.
Range of two, three and four pump cold water booster sets. The products incorporate a suction and discharge manifold and pumps. Maximum working pressure 10 bar. Cold water use only.
‘AMV-FB’ and ‘AMV-FE’ range of two, three and four pump cold water booster sets. The products incorporate a suction and discharge manifold, vertical multistage pumps, expansion vessel, isolation valves, pressure sensor and flow regulator. Maximum working pressure 10.0 bar. Cold water use only.
Range of horizontal multistage close coupled centrifugal pumps incorporating stainless steel cased bodies and impellers. Maximum working pressure: See models. Cold water use only.
Range of shower handsets with plastic bodies (various finishes), handset holder, riser rail and TPE inner lined multilayered shower hose. The handset incorporates a flow restrictor at the inlet. Open Outlet. Maximum operating temperature: 60.0°C.
Range of ABS plastic shower handsets, (various finishes) Maximum operating temperature 85°C.
A range of wall mounted shower handsets (brass bodies) incorporating approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection, and plastic flow regulators. The products are also supplied with shower hoses and handset holders. Maximum operating temperature 60.0°C Open outlet use only.
Range of shower outlets (brass bodies – various finishes) incorporating a PEX lined hose as an inner pathway with an aerator type outlet. Open outlet use only. Maximum operating temperature 60.0°C
Range wall mounted shower outlet connectors with brass bodies, chrome finish. The outlet incorporates a single check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). Maximum operating pressure 10 Bar. Maximum operating temperature 70°C.
Range of overhead shower outlets, wall and ceiling mounted shower arms with (brass bodies - various finishes). The overhead shower inlet incorporates a combined NBR washer and stainless steel strainer. Maximum operating pressure 5 bar. Maximum operating temperature 85°C
Range of shower handsets and overhead showers, (plastic bodies - various finishes). The inlets incorporate a plastic flow restrictor and stainless steel strainer. Maximum operating temperature 60°C. Open outlet use only.
Page 192 of 222
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.