Single hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet can incorporate either a plastic flow straightener or a plastic aerator. When supplied with a plastic flow straightener there is a combined EPDM washer and stainless steel strainer behind it. The products are available either as a version with a pop-up waste or one with a click type waste. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Single-hole, single outlet, (fixed) combination tap assembly with brass bodies (chrome plated), incorporating non-rising spindle headworks with cross top operating members. The spout incorporates a plastic flow straighter this product is also supplied with an additional aerator. Model CL4 is supplied with a pop-up waste. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet, (swivel) combination tap assemblies incorporating brass bodies (chromium plated) and quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass) incorporating ceramic cartridge headwork with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet can incorporate either a plastic flow straightener or a plastic aerator. When supplied with a plastic flow straightener there is a combined EPDM washer and stainless steel strainer behind it. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
A range of single-hole, single outlet, (swivel) combination tap assemblies (various finishes), incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Models 71554XXX and 71564XXX are supplied with pop-up wastes. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
A single-hole single outlet swivel combination tap assembly (chromium plated brass) incorporating a ceramic cartridge headwork with a single lever operating member. The outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum working temperature 60°C.
A range of single hole single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating either ceramic cartridge or quarter turn ceramic disc headwork with a single lever, cross top or dome type operating member. The spout outlets incorporate either a plastic flow straightener or aerator. Model SH-T81072 is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass) incorporating a rising spindle headwork with a single lever operating member. The spout outlets incorporate a plastic flow straighter and the products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Wall mounted, single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a rising spindle headwork with a single lever operating member. The spout outlets incorporate a plastic flow straighter and the products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) with ceramic cartridge headworks and single lever operating members. The discharge is via the hand spray outlet or the infra-red controlled outlet on the swivel arm. The cold Inlet has a single check valve assembly (suitable for protection against fluid category 2 backflow). The spouts incorporate a plastic aerator. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated brass), incorporating a two quarter turn ceramic disk headworks and cross top operating members. The spout outlet incorporates a flow straightener. Supplied with single check valves (suitable for backflow protection against Fluid Category 2) with integral servicing valve for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated or brushed nickel coated brass), incorporating two quarter turn ceramic disk headworks and lever operating members. The spout outlet incorporates a plastic aerator. Supplied with single check valves (suitable for backflow protection against Fluid Category 2) with integral servicing valve for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of single hole, double outlet (fixed) combination tap assemblies (various finishes) with electronically controlled functions to allow the tap to dispense boiling water, chilled water or sparkling water from under counter units (not supplied). The spout outlet of ‘Arc’ models incorporates a plastic flow straightener. All models incorporate a separate vent outlet within the tap spout for the near-boiling water circuit. Near-boiling circuit has a maximum operating temperature 100°C. Hot-water circuit has a maximum operating temperature of 65°C.
Range of two hole, single outlet (fixed) combination tap assemblies incorporating brass body (chromium plated) and ceramic disc headwork with dome type operating members The temperature is controlled independently via a thermostatic cartridge with dome type operating member and manual override button. The spout outlet incorporates a plastic flow straightener. Both inlets incorporate a stainless steel strainers and an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 45°C.
Two hole, single outlet fixed combination tap assembly (chrome plated brass) incorporating a ceramic cartridge headwork and a single lever operating member. The tap body and spout oulet are connected via a stainless steel braided EPDM lined flexible hose. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed), combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener and the product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Wall mounted, two-hole, single outlet (fixed) combination tap assembly (chromium plated brass), incorporating a quarter turn ceramic cartridge headwork with single lever operating member. Both inlets incorporate eccentric isolation valves and plastic flow regulators. The spout outlets incorporate plastic flow straighteners. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chrome plated brass) incorporating two quarter turn ceramic disc headwork with single lever operating members. The spout outlet incorporates a plastic flow straightener and the product is supplied with metal back nuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Two hole, single outlet (fixed) combination tap assembly (chrome plated brass) incorporating a single sequential headwork which controls flow and temperature with a single lever operating member. Both inlets incorporate eccentric isolation valves, flow restrictors and single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator and the product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Wall mounted two hole, single outlet (fixed) combination tap assembly (chrome plated brass) incorporating a single sequential headwork which controls flow and temperature with a single lever operating member. Both inlets incorporate eccentric isolation valves, flow restrictors and single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator and the product is supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Wall mounted two hole, metal, single outlet (fixed) combination tap assembly (brass body in various finishes - see model), incorporating a 2 way ceramic disc diverter controlling the flow between the spout outlet and the shower outlet with a dome type operating member. Temperature is controlled independently via a thermostatic cartridge with a dome type operating member which incorporates a manual override button. The spout outlet incorporates a plastic aerator. Each inlet incorporates a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of two-hole, single outlet, (swivel) combination tap assemblies (chrome plated brass) incorporating a ceramic cartridge headwork with single lever type operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating rising spindle headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, three-hole, single outlet (fixed) combination tap assemblies (brass body with various finishes) incorporating quarter turn ceramic disc headworks with cross top type operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of combined bath fillers and overflow waste assemblies with plastic bodies (various finishes). The outlet incorporates a plastic aerator and the product is supplied with a cable operated pop-up waste. Maximum operating temperature 60°C.
Bath spout with brass body (chromium plated). The outlet incorporates a plastic aerator. Maximum operating temperature 60°C.
Range of water filter systems with optional distributor heads. The inlets incorporate a non-return valve. Maximum working pressure 6.9 bar. Cold water use only.
Range of complete water filter heads and compatible filter cartirdges with plastic bodies and EPDM ‘O’-rings. The FX filters are carbon block based and the VH-IEN filters use an ion exchange resin. Maximum working pressure 8.6 bar. Cold water use only.
Uponor S-Press (black and grey) composite fittings, Uponor S-Press composite PPSU reducers with S-Press PLUS composite PPSU nipples, Uponor RS fittings & Uponor S Press Metal Press fittings for use with for use with Uponor MLC pipe. Maximum working pressure and operating temperature: 10.0 bar@70°C Maximum working pressure and operating temperature: 16.0 bar @ Cold water use only.
Range of press fittings with a stainless steel body and EPDM ‘O’ rings for use with stainless steel 316L pipe manufactured to EN10312. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of polypropylene push-fit fittings and inserts for use with MDPE pipe (manufactured to BS EN 12201). For above and below ground use. Maximum working pressure 16.0 bar. Cold water use only.
Range of brass and copper fittings for use with EN 1057 copper tube. For above ground use only. Maximum working pressure 18.6 bar. Maximum operating temperature 100°C.
Range of single flush siphonic WC outlet valves comprising of a plastic body, LDPE diaphragm washer and stainless steel C link. Cold water use only.
Range of stainless-steel heat exchangers. Maximum working pressure of primary Circuit 3.0 bar. Maximum working pressure of secondary Circuit 10.0 bar. Maximum operating temperature 80˚C
Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.
Range of RINNAI continuous flow water heaters with stainless steel plate heat exchangers providing heating and instantaneous hot water .The hot water is generated via a plate heat exchanger. Also supplied is a drain valve and a flow sensing device. Maximum working pressure - 10 bar Maximum working pressure - 85˚C
Shower waste water heat recovery unit, consisting of a PVC-U waste pipe with an internal copper tube which provides a double wall separation between the waste water and cold mains supply. Maximum working pressure 10.0 bar. Maximum operating temperature 30°C.
Gas fired water heaters incorporating a heat exchanger and flow sensor. The inlet incorporates a plastic strainer. The products are supplied with isolation valves for installation on the cold inlet and hot outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 60˚C
Range of gas fired condensing water heaters incorporating stainless steel storage tank, buffer tank and strainer on the cold water inlet. Maximum working pressure 10.0 Bar, maximum working temperature 83˚C.
LCB700 range of internal and external oil-fired condensing combination boilers providing domestic hot water and pressurised central heating via a plate heat exchanger. The products are supplied with a temporary filling loop which incorporates a combined isolation valve and double check valve assembly (suitable for backflow protection against Fluid Category 3), stainless steel braided EPDM lined flexible hose assembly and an isolation valve. The primary (space heating) circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). Operating parameters: Primary (space heating) circuit: Maximum working pressure 2.5 Bar. Maximum operating temperature 105°C. Secondary (DHW) circuit: Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.
Range of heat interface units (HIU) with either twin or single stainless steel copper brazed plate heat exchangers (depending on model) providing heating and hot water (twin unit) hot water only, or heating only. The hot water is generated via a plate heat exchanger. The primary (space heating) circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product incorporates a CAb backflow prevention device (suitable for backflow protection against Fluid Category 3) for filling the heating circuit. The inlet and outlet of all circuits incorporate a lever operated spherical valve. Maximum working pressures and operating temperatures: Primary (district heating): 10.0 bar and 85˚C. Domestic hot water (DHW): 10.0 bar and 60˚C. Secondary (space heating): 2.5 bar and 80˚C.
Range of ice making machines which incorporate a solenoid valve to control the flow. Maximum working pressure 5.0 bar. Cold water use only.
Range of water meters with plastic or brass bodies. The inlets incorporate a plastic strainer. Maximum working pressure 16.0 bar. RTKD range has a maximum operating temperature of 50°C. RTKD-L range has a maximum operating temperature of 30°C.
Ultrasonic water meter with a blue epoxy coated ductile iron body and EPDM ‘O’ rings. Maximum working pressure 16.0 Bar. Maximum operating temperature 50°C.
Range of water meter manifolds with plastic bodies. The inlets incorporate a spherical valve and a non-return valve (not suitable for back flow protection). Model MD1010101BM is for use with Irish Heavy gauge pipe manufactured to 15134/1977. All other models are for use with blue MDPE pipe manufactured to EN12201. Maximum working pressure 12.5 bar. Cold water use only.
Range of water meter manifolds with a plastic body and a spherical valve at the inlet. Models MB2012525DM & MB2010303DM incorporates two single check valve cartridges, all other models incorporate one single check valve however, the complete product has not been fully tested to demonstrate it provides backflow protection Model MB201010BM is for use with Irish Heavy gauge pipe manufactured to 15134/1977. All other models are for use with blue MDPE pipe manufactured to EN12201. Maximum working pressure 12.5 bar. Cold water use only.
Page 20 of 225
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.