Unidelta range of compression fittings with polypropylene bodies with EPDM ‘O’ rings for use with PE100 polyethylene pipe (manufactured to EN12201). Maximum working pressure 16.0 bar. Cold water use only.
Range of copper press fittings with EPDM rubber ‘O’-rings for use with copper pipe (manufactured to EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of M type press fittings with TP2 copper bodies and EPDM ‘O’-rings, for use with TP2 copper pipe to EN1057. Above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of single and dual flush WC outlet valves with ABS body and EPDM seating washers. The valve incorporates an internal overflow and is operated via a push button assembly for either full or reduced flush. Cold water use only.
Dual flush WC outlet valve with ABS body and EPDM seating washers. The valve incorporates an internal overflow and is operated via a push button assembly for either full or reduced flush. Cold water use only.
Concealed wall insulation unit with a brass body and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C.
Range of shower hoses and riser rail with chromium plated brass bodies, incorporating EPDM ‘O’-rings. Maximum operating temperature 85°C.
Range of plastic bodied quarter turn isolation valves, with EPDM rubber ‘O’-rings, seals and washers. The 52.009.100 model is operated by a hex key (not supplied), the 52.009.200 model is operated by a key (supplied). Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Appliance inlet group assembly comprising of EPDM gaskets, a plastic bodied Y-pattern strainer, ¾” BSP (F) x ½” BSP (F) brass adaptor, a chrome plated DZR brass bodied double check valve assembly (suitable for backflow protection against Fluid Categry3), a ½” BSP (F) x ¾” BSP (M) brass adaptor, a dual layer hose with a PVC outer (grey) and PVC liner (black), a solenoid valve which incorporates a plastic strainer and a flow regulator within the inlet. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Appliance inlet group assembly comprising of an EPDM gasket, ¾” BSP (F) x ½” BSP (F) brass adaptor, a chrome plated DZR brass bodied double check valve assembly (suitable for backflow protection against Fluid Categry3), a ½” BSP (F) x ¾” BSP (M) brass adaptor, a flexible reinforced hose assembly with a PVC lining and a solenoid valve which incorporates a plastic strainer and a flow regulator within the inlet. Maximum working pressure 5.0 bar. Cold water use only.
Range of circulation fittings with gun metal bodies, plastic cones & guides and EPDM ‘O’ rings. The products incorporate a dynamic venturi valve. Maximum working pressure 16.0 bar. Maximum operating temperature 65°C.
Bath spout incorporating a brass body (various finishes), EPDM ‘O’-rings and a plastic flow straightener. Maximum operating temperature 60°C
Range of pushfit hose connectors with either plastic (white or black) or chrome plated brass bodies and EPDM ‘O’-rings. SHCV prefix models incorporate screwdriver operated servicing valves. All pushfit connections are for use with PEX pipe (manufactured to BS7291-3) and copper pipe (manufactured to EN1057). Barbed end connections are not approved for use with any hose. Chrome plated brass body models are also for use with PB pipe (manufactured to BS7291-2). Maximum working pressure 10.0 bar (servicing valve models only). Barbed end connections are open outlet use only. Cold water use only.
Range of flexible joints incorporating an EPDM (inner & outer) joint with a steel reinforcing ring and two carbon steel flanges. Maximum operating pressure 16.0 bar. Maximum operating temperature 65°C.
Range of flow control valves for domestic hot water with plastic bodies and EPDM ‘O’-rings The products incorporate a motor which adjusts the flow, a flow sensor which measures the flow rate and a plastic filter on the inlet. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Chrome plated brass quick connector with EPDM washer. Maximum operating temperature 60°C.
Range of booster pumps with stainless steel bodies and impellers, EPDM ‘O’-rings and a ceramic/graphite/EPDM shaft seal. Maximum working pressure 6.0 bar. Maximum operating temperature 40°C.
Range of booster pumps with stainless steel bodies and impellers, EPDM ‘O’-rings and a ceramic/graphite/EPDM shaft seal. Maximum working pressure 7.0 bar. Cold water use only. From November 2021 maximum operating temperature 60°C
Range of cast iron (blue epoxy coated) (G versions only) or stainless steel (all other versions - F, N, R, T) vertical multistage pumps with stainless steel impellers, shaft and outer sleeve and EPDM 'O'-rings and seals. The pumps incorporate a ceramic/carbon graphite/EPDM and stainless steel mechanical shaft seal (QBEGG). Maximum working pressures: 1-22SV models: 1SV27-1SV37 (F VERSION) - PN16 (25mm). 3SV23-3SV33 (F VERSION) - PN16 (25mm). 5SV23-5SV33 (F VERSION) - PN16 (32mm). 10SV27-10SV21 (F VERSION) - PN16 (40mm). 15SV11-15SV17 (F VERSION) - PN16 (50mm). 22SV12-22SV17 (F VERSION) - PN16 (50mm). 1SV02-1SV25 (F VERSION) - PN25 (25mm). 3SV02-3SV21 (F VERSION) - PN25 (25mm). 5SV02-5SV16 (F VERSION) - PN25 (32mm). 10SV01-10SV13 (F VERSION) - PN25 (40mm). 15SV01-15SV10 (F VERSION) - PN25 (50mm). 22SV01-22SV10 (F VERSION) - PN25 (50mm). N VERSIONS ALL MODELS - PN25 (25-50mm). R VERSION ALL MODELS - PN25 (25-50mm). T VERSION ALL MODELS - PN16 (25-50mm). 33-125SV models: 33SV1-33SV5, 33SV6/2AG150T/D & 33SV6/2AN150T/D (G or N VERSION) - PN16 (65mm). 46SV1-46SV5 (G or N VERSION) - PN16 (80mm). 66SV1-66SV5 (G or N VERSION) - PN16 (100mm). 92SV1-92SV4 (G or N VERSION) - PN16 (100mm). 125SV1-125SV6 (G VERSION) - PN16 (125mm). 33SV7-33SV10, 33SV6/1AG150T/D, 33SV6/1AN150T/D, 33SV6G150T/D & 33SV6N150T/D (G VERSION) - PN25, (N VERSION) - PN16 (65mm). 46SV6-46SV9 (G VERSION) - PN25, (N VERSION) - PN16 (80mm). 66SV6-66SV8 (G VERSION) - PN25, (N VERSION) - PN16 (100mm). 92SV5-92SV7 (G VERSION) - PN25, (N VERSION) - PN16 (100mm). 125SV7-125SV8 (G VERSION) - PN25 (125mm). 33SV10-33SV13 (G VERSION) - PN40 (65mm). 46SV10-46SV13 (G VERSION) - PN40 (80mm). Cold water use only. VERSION) - PN25 (100mm). 92SV5-92SV7 (G or N VERSION) - PN25 (100mm). 125SV7-125SV8 (G or N VERSION) - PN25 (125mm). 33SV10-33SV13 (G VERSION) - PN40 (65mm). 46SV10-46SV13 (G VERSION) - PN40 (80mm). Cold water use only.
Range of booster pumps with stainless steel bodies and impellers (AISI 304: AL-RED models or AISI 316: CP models), EPDM ‘O’-rings and a ceramic/graphite/EPDM shaft seal. Maximum working pressure: CP(m) 100-130-132-150-158 and AL-RED(m) 600-610-620 models: 6.0 bar. All other models: 8.0 bar. Maximum operating temperature 90°C.
Page 20 of 109
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.