Wall mounted, bar type, thermostatic shower mixer (chromium plated brass), incorporating a 2-way ceramic disc diverter headwork with a dome type operating member controlling the flow between each shower outlet. The temperature is controlled independently via a thermostatic cartridge with a dome type operating member incorporating a manual override button. Both inlets incorporate a stainless-steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection The product is supplied with a shower hose (metal interlocked), shower handset (chrome plated), riser rail and overhead shower. The shower handset and the overhead shower both incorporate a stainless-steel strainer on the inlet. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, exposed, thermostatic shower mixing valves (chromium plated brass). The products incorporate a ¼ turn ceramic disc or a 2-way ceramic disc diverter headwork (see model). Temperature is controlled independently via a thermostatic cartridge with a manual override button. All models have cube operating members except model 706128 which has dome operating member. Each inlet incorporates a combined EPDM washer and stainless steel strainer and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Wall mounted thermostatic blending valve (chromium plated brass). Temperature is controlled via a thermostatic cartridge with a cube operating member incorporating a manual override and the flow is controlled via two push type cartridges for the shower outlets. The inlets incorporate stainless steel strainers and approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, thermostatic shower valves with brass bodies (various finishes), incorporating a thermostatic cartridge controlling the temperature and a push shut-off valve controlling the flow. The inlets and the shower outlet incorporate approved check valve cartridges, however, the complete products have not been fully tested to demonstrate they provide backflow protection. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C.
Wall mounted, manually operated blending valve with a brass body (various finishes) and ceramic cartridge headwork a single lever operating member. The outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 70.0°C
Range of wall mounted, thermostatic shower valves with brass bodies (various finishes). Flow is controlled with a ceramic disc headwork with a single lever operating member. Temperature is controlled independently by a thermostatic cartridge with a single lever operating member with a manual override button. Each inlet incorporates a stainless steel strainer and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Wall mounted, manual blending valve (brass body, various finishes) incorporating a ceramic cartridge headwork with a single lever operating member. This product is not claimed to provide any backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of thermostatic shower panels incorporating a single sequential thermostatic control valve with a single lever operating member and flexible riser kit. Each inlet supplied with a servicing valve, EPDM o-ring and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Products are supplied with black lined PVC shower hoses and chrome plated shower handsets. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Range of wall mounted concealed thermostatic blending valves with plastic bodies (various finished face plates). The flow is controlled by a ceramic disc diverter headworks with a cube type operating members. The temperature is controlled by a thermostatic cartridge with dome type operating members incorporating a manual override button. Both inlets incorporate an approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Wall mounted thermostatic shower valve with brass body (various finishes), incorporating a ceramic disc diverter that controlling the flow with a cube type operating member. The temperature is controlled independently via a thermostatic cartridge with a cube type operating member incorporating a manual override button. Both inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Range of wall mounted concealed (BIV & BIR models) and exposed (EV model) thermostatic shower control valves. The bodies are cast brass (concealed versions) with a chromium plated trim set or chromium plated brass (exposed versions). Flow and temperature are controlled by a thermostatic cartridge with a single lever operating member. The inlets incorpoarate stainless steel strainers. Some models are supplied with a shower hose and handset or an overhead shower arm and shower head with flow regulator (see model section). The BIV model is also supplied with an angled wall outlet elbow. Maximum working pressure 5.0 bar. Maximum operating temperature 45°C.
Range of lugged and wafer type butterfly valves with blue epoxy coated bodies, incorporating EPDM rubber ‘O’-rings and seat, and either a bronze (AB2), stainless steel (CF8 & CF8M) or blue epoxy coated or nickel plated, ductile iron (DI) disc. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of wafer and lug type butterfly valves incorporating blue epoxy coated ductile iron bodies, either stainless steel (SS316/SS304) or epoxy coated ductile iron discs and EPDM seat. The valves are either handwheel and gear operated (Models SD-BVG16 and SD-16BVLL) or lever operated (Models SD-BVL125 and SD-16BVGL). Maximum working pressure 16.0 bar Maximum operating temperature 85°C.
Range of concealed manual diverters (brass bodies) with chrome trim sets, model RAKPES3020-1C incorporating a dome type operating member and model RAKPER3020-1C incorporating a single lever operating member. Maximum working pressure – 5.0 Bar Maximum operating temperature - 85 °C
Range of inline manually adjustable pressure reducing valves with DZR brass or bronze bodies (see model), EPDM diaphragm, seat washers and ‘O’-rings. Adjustable outlet pressures between 1.0 and 7.0 bar. Maximum inlet supply pressure 25.0 bar. Maximum operating temperature 80°C.
Range of pressure reducing valves with DZR brass, gunmetal or stainless-steel bodies. Maximum inlet pressure for HP and SP Models = 25.0 bar. Maximum inlet pressure for LP Models = 6.0 bar. Between September 2022 and December 2023, the maximum operating temperature of models included on the approval was 60°C. From January 2024, the maximum operating temperature of those models increased to 85°C. Models added to the approval in January 2024: Models with maximum working pressure of 6.0 & 16.0 bar models are for cold water use. Models with maximum working pressure of 25.0 bar have a maximum operating temperature of 85°C.
Range of combination valves with a DZR brass body incorporating a pressure reducing valve, a ball valve, pressure gauge and water meter port. The outlet incorporates two single check valve cartridges, verified by test suitable for backflow to fluid category 3. Maximum working pressure 16 Bar Outlet pressure in the range 6.0 to 1.5 bar. Maximum operating temperature 80°C
Manifold spherical valve with DZR brass body and ball (chrome plated), incorporating a single lever type operating members and a single check valve assembly (verified by test as suitable for backflow protection against Fluid Category 2). For use with with copper pipe manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of spherical valves with nickel plated brass bodies, chromium plated brass balls, PTFE seals, NBR and/or FKM ‘O’-rings. 140, 140M, 141 & 141M series models incorporate a stainless-steel strainer. 140 & 141 series models also incorporate a magnet. The 121 & 122 series models are 3-way valves. Maximum working pressure: See PN in brackets under model. Maximum operating temperature: Cold water use only.
Range of lock shield or handwheel operated gate valves with brass bodies, gate & PTFE seals, for use with copper tube manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Page 173 of 508
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.