Range of four-hole, single outlet combination tap assemblies with various finishes (see models) Incorporating a ceramic cartridge headwork controlling the flow to the shower handset and quarter turn ceramic headworks controlling flow to the spout outlet, all with single lever operating members. The product is supplied with a shower hose and handset, the handset incorporates a single check valve on the inlet, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of floor mounted, swivel, bath mixers (brass or stainless-steel bodies - variety of finishes (see models), incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate plastic aerators. The products also incorporate self-cancelling diverters to a shower handset. The diverter outlets incorporate an approved check valve cartridges, however, the complete products have not been fully tested to demonstrate they provide backflow protection. Maximum working pressure 5.0 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of combined bath filler and overflow waste assemblies incorporating a cable operated pop-up waste. The outlet incorporates a plastic flow straightener. Maximum operating temperature 60°C.
Range of wall mounted brass bodied spout outlets (various finishes, see model) incorporating a plastic aerator. Maximum working pressure 10.0 Bar
Non-metallic materials and components comply with BS6920 at 60°C
Wall mounted spout outlet, (brass body, various finishes – see model).
Non-metallic materials and components comply with BS6920 at 65°C
Range of deck mounted spout outlets (fixed or swivel - see model, chromium plated brass) incorporating a plastic flow straightener. The products are supplied with metal backnuts.
Non-metallic materials and components comply with BS6920 at 60°C
Range of swivel spout outlets with brass or stainless-steel bodies supplied in various finishes (see model). The products also incorporate a plastic aerator. Maximum working pressure 10.0 Bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of longitudinal (EFW) welded stainless steel (Grade 304/304L & 316/316L) pipes. Maximum working pressures: 1¼” sch 10: below ground = 55.0 bar. Above ground = 74.0 bar. 1½” sch 10: below ground = 48.0 bar. Above ground = 64.0 bar. 2” sch 10: below ground = 38.5 bar. Above ground = 51.0 bar. 2½” sch 10: below ground = 34.5 bar. Above ground = 46.0 bar. 3” sch 10: below ground = 28.0 bar. Above ground = 38.0 bar. 4” sch 10: below ground = 22.0 bar. Above ground = 29.0 bar. 5” sch 10: below ground = 19.5 bar. Above ground = 26.0 bar. 6” sch 10: below ground = 16.0 bar. Above ground = 22.0 bar. 8” sch 10: below ground = 14.0 bar. Above ground = 18.0 bar. ½” sch 40 & ¾” sch 40: below ground = 60.0 bar. Above ground = 80.0 bar. 1” sch 40: below ground = 30.0 bar. Above ground = 40.0 bar. 1¼” sch 40 & 1½” sch 40: below ground = 60.0 bar. Above ground = 80.0 bar. 2” sch 40: below ground = 54.5 bar. Above ground = 72.0 bar. 2½” sch 40: below ground = 60.0 bar. Above ground = 80.0 bar. 3” sch 40: below ground = 52.0 bar. Above ground = 69.0 bar. 4” sch 40: below ground = 44 bar. Above ground = 58.0 bar 5” sch 40: below ground = 38.5 bar. Above ground = 51.0 bar. 6” sch 40: below ground = 35.0 bar. Above ground = 46.0 bar. 8” sch 40: below ground = 31.0 bar. Above ground = 41.0 bar. Maximum operating temperature 100°C.
“Super Speedfit” range of push-fit fittings with polypropylene bodies and EPDM or NBR ‘O’-rings (NC2301 model only) for use with John Guest LLDPE tubing (blue, black, natural, green, orange, red, white and yellow). Maximum working pressure and maximum operating temperature: 10bar @20°C, 4 bar @60°C.
CB Ranges of brass, DZR brass, chromium plated brass, nickel plated brass and DZR brass compression fittings for use with copper pipe to BS EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
CB ranges of brass, chromium plated brass, nickel plated brass and DZR brass compression fittings for use with copper pipe (manufactured to to BS EN1057:2006 + A1:2010). Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Ranges of brass & chromium plated brass, nickel plated brass compression fittings for use with copper pipe to BS EN 1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of press-fit fittings with stainless steel bodies incorporating EPDM ‘O’-rings for use with SS316L pipes. Maximum working pressure 16 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Dual flush, WC outlet valve. The valve is operated via a sensor for either full or reduced flush and the valve incorporates an internal overflow. Cold water use only.
Range of commercial air or liquid cooled ice making machines with water controlled via solenoid valve. Maximum working pressure 5.5 Bar COLD WATER USE
Range of water meters with brass bodies, plastic turbines and EPDM washers. Inlets incorporate a plastic filter. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
‘V200’ range of rotating piston (semi positive) volumetric in-line water meters with brass bodies, EPDM ‘O’-rings and seal (DN40 model only), NBR ‘O’-rings (all other models) and seal (DN15 36RPL model only). Maximum working pressure 16.0 bar. Cold water use only.
Range of inline water meters with brass (16.0 bar models) or bronze (20 bar model) bodies and plastic turbines. Model FL040FM300 has a plastic filter. All models excluding FL150KP450_00_UK: Maximum working pressure 16.0 bar Model FL150KP450_00_UK only: Maximum working pressure 20.0 bar. Cold water use only.
Range of ultrasonic water meters with plastic (PL) or brass (BR) bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating Temperature 50 C
Range of ultrasonic water meters with brass bodies and EPDM ‘O’-rings and plastic strainer. The products incorporate a motor operated isolation valve. Maximum working pressure 16.0 bar. Maximum operating temperatures: LXC-15 model: 65°C. LXC-20 model and models added May 2025: 85°C
Page 123 of 311
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.