Range of M type press fittings with TP2 copper bodies and EPDM ‘O’-rings, for use with TP2 copper pipe to EN1057. Above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of urinal flushing mechanisms with a solenoid valve controlling the flow. The valves are controlled via an infra-red sensor. The inlet incorporates a stainless steel strainer and flow regulator. Maximum working pressure 10.0 bar. Cold water use only.
A range of under sink electrically heated vented water heaters (cased and insulated) with a stainless-steel cylinder incorporating a temperature sensor and a float switch (not flow control) Maximum operating temperature 98°C.
Range of commercial air or liquid cooled ice making machines with flow controlled via solenoid valve. Maximum working pressure 7.8 Bar. Cold water use only.
‘Aquila V4 C1’ range of water meters (brass or bronze bodies) with a plastic working chamber, flow regulator and impellor, and either NBR or EPDM ‘O’-rings. The products are supplied with loose NBR/fibre flange gaskets. Maximum working pressure 16.0 bar. Cold water use only.
A range of water meters incorporating brass or plastic bodies (See models), EDPM ‘O’-rings, plastic strainer on the inlet and a plastic impellor. Maximum working pressure 16.0 bar. Maximum working temperature 85°C (brass bodies) or cold water use only (plastic bodies)
Range of meter boxes incorporating a plastic manifold arrangement consisting of a stop valve with non-rising spindle , check valve (however the complete assembly has not been tested to demonstrate it provides adequate backflow) and concentric meter port. Some models incorporate a drain off or blacking plug. Connections can be compression or push fit (see model). For use with PE8-0 pipe to BS EN 12201 and copper to EN 1057. Maximum working pressure 16.0 bar. Cold water use only.
Copper corrugated hose. Maximum working pressure 10.0 bar. Maximum working temperature 90°C.
Range of pushfit hose connectors with either plastic (white or black) or chrome plated brass bodies and EPDM ‘O’-rings. SHCV prefix models incorporate screwdriver operated servicing valves. All pushfit connections are for use with PEX pipe (manufactured to BS7291-3) and copper pipe (manufactured to EN1057). Barbed end connections are not approved for use with any hose. Chrome plated brass body models are also for use with PB pipe (manufactured to BS7291-2). Maximum working pressure 10.0 bar (servicing valve models only). Barbed end connections are open outlet use only. Cold water use only.
Range of water hammer arrestor’s incorporating brass bodies (various finishes). The 525152 model is supplied with a reinforced captive nut. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C. For products manufactured from June 2023 Maximum operating temperature 85°C
Page 119 of 788
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.