Range of in-line “Y” patterned strainers with brass bodies incoroporating NBR ‘O’-rings and stainless steel filters. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Drain cock elbow incorporating a DZR brass body with EPDM ’O’-rings (ZELB250445 model) or NBR ‘O’-rings (ZELB250446 model added July 2022). Both models are for use with copper pipe (manufactured to BS EN 1057). Maximum working pressures: ZELB250445 model - 10.0 Bar. ZELB250446 - 16.0 bar. Maximum operating temperature 85°C.
Range of pillar taps (chrome plated brass) with non-rising spindle headworks and cross type operating members. The spout outlets incorporate a plastic flow straightener and the products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of self-closing basin taps (chromium plated brass) with spring loaded headwork and dome type operating members. The spout outlets incorporate a plastic aerator and the products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60⁰C.
Range of stainless steel braided PE-X lined flexible hose assemblies incorporating NBR washers and various end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
‘Platinox SLP’ range of stainless steel braided silicone lined flexible hose assemblies with a variety of end connections (see size). Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of vertical cased and insulated direct and indirect unvented stainless steel hot water storage cylinders. The storage cylinders incorporate an internal air bubble to accommodate the expansion of hot water. The DHW circuit has a factory fitted temperature and pressure relief valve set at 10.0@90˚C. The inlet control group includes a pressure reducing valve set at 3.0 bar, single check valve cartridge (verified by test and suitable for backflow protection against Fluid Category 2) and a expansion valve set at 8.0 bar. The products are supplied with a tundish and a motorised valve to be installed on the primary indirect circuit. Maximum supply pressure to the pressure reducing valve is 12.0 bar. Maximum working pressure of primary circuit is 6.0 bar. Maximum secondary circuit is 9.5 bar. Maximum operating temperature 85°C.
Wall mounted concealed thermostatic shower valve, with a single sequential headwork controlling both flow and temperature. A manual diverter controls the flow between a shower handset or overhead shower. The inlets incorporate a single check valve however the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 50°C.
Range of wall mounted, concealed, manual blending valves (chromium plated brass) incorporating a ceramic cartridge headwork, with a single lever operating member, controlling both flow and temperature. Model 36011660 is supplied with a shower hose and handset. The outlets incorporate an approved check valve cartridge however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of thermostatic mixing valves incorporating brass bodies (chrome plated). The flow is controlled by quarter turn ceramic disc headwork, with dome or cube type operating members, which also diverts the flow between multiple shower outlets. The temperature is controlled by a thermostatic cartridge with dome or cube type operating members. Both inlets incorporate stainless steel strainers and approved check valve cartridges, however, the complete products have not been fully tested to demonstrate that they provide backflow protection. The products are supplied with a shower hose, shower handset and overhead shower outlet. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of two way and three way concealed thermostatic shower valves, incorporating brass bodies and ceramic disc headwork with dome type operating members which controls the flow and diverts to various shower outlets. Temperature is controlled by a thermostatic cartridge incorporating a manual over ride button. Inlets incorporate stainless steel filters and an approved single check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of concealed thermostatic mixing valves, incorporating quarter turn ceramic disc headworks, with dome type operating members, controlling the flow to multiple shower outlets. The temperature is controlled independently via a thermostatic cartridge with dome type operating member. The inlets incorporates stainless steel strainers an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of 1, 2 or 3 outlet concealed wall mounted bar type thermostatic mixer valve (various finishes) incorporating a quarter turn ceramic disc headwork controlling the flow using a single lever or cross top operating member depending on the model type. The temperature is controlled independently via a thermostatic cartridge also using a cross top or single lever type operating member (Depending on model). Inlets incorporate stainless steel strainers and approved single check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. some models are supplied with a shower handset and hose. Maximum working pressure 5.0 bar. Maximum operating temperature 65.0°C
Range of thermostatic mixing valves with between 1 and 6 outlets. Flow is controlled by a solenoid valve and temperature is thermostatically controlled. Models Mira Activate 1.1903.091, 1.1903.092 & 1.1903.093 incoporate a built-in pump which is set 12 litres per minute. The valves can be supplied with a shower rail, hose, handshower and/or ceiling mounted shower outlet. The inlets of the valves incorporate an isolation valve, stainless steel strainer and a single check valve cartridge however, the complete assembly has not been tested to demonstrate it provides adequate backflow protection. Valves with ‘HP’ in model have a maximum working pressure of 5.0 bar. All other valves have a maximum working pressure of 1.0 bar. Maximum operating temperature 50°C.
Range of wall mounted thermostatic mixers incorporating a brass body (chromium plated) and ceramic disc headwork with dome type operating members The temperature is controlled independently via a thermostatic cartridge with dome type operating member and manual override button. Both inlets incorporate a stainless steel strainers and an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Model 1.1900.018 is supplied with a shower handset and riser rail. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of deck mounted thermostatic mixers incorporating brass body (chromium plated) and ceramic disc headwork with dome type operating members The temperature is controlled independently via a thermostatic cartridge with dome type operating member and manual override button. Both inlets incorporate a stainless steel strainers and an approved single check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Products are supplied with a shower hose, shower handset and shower rail. Maximum working pressure 5.0 bar. Maximum operating temperature 45°C.
Range of wall mounted thermostatic shower valves incorporating chrome plated brass bodies. Product is supplied with a shower hose, handset and riser rail and over head shower. Maximum working pressure 5.0 bar. Maximum operating temperature 50°C.
Combined temperature and pressure relief valve incorporating a gunmetal body and manually operated lever-type easing gear. Factory set at 7.0 bar. Maximum operating temperature 95°C.
Range of ceramic disc diverter valve headworks with plastic bodies for use in specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of ‘J2 10 series’ of equilibrium float valves with cast iron (epoxy coated) bodies and EPDM seals. Available with either standard or extended arms. Maximum working pressure 10 bar. Cold water use only.
Page 12 of 206
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.