Range of water meter manifolds with gun metal bodies and ball valve with either a quarter turn stop valve or screw down stop valve. The products incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Cold water use only.
Range of pump inverters with plastic bodies, NBR rubber and EPDM rubber seals and ‘O’-rings. The products incorporate an inline resilient trim non-return valve. Maximum working pressure 13.0 bar. Cold water use only.
Range of spout outlets with brass bodies (various finishes) incorporating an aerator. Product is supplied with either a lever type pop up (HIRONDELLE models) or click type waste (ICON-X & CORVAIR models). Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Circulation pump incorporating a plastic body and impellers. Maximum working pressure 15.0 bar. Maximum operating temperature 95°C.
Range of cold water in tank booster sets incorporating an ‘AG’ air gap, consisting of a GRP water storage cistern incorporating a float operated inlet valve, with a copper float and submersible pump or pumps (depending on model). The products incorporate an externally mounted stainless-steel manifold with servicing valve(s), expansion vessel, pressure gauge and a digital control panel. The pumps are connected to the external components via a discharge assembly of internal pipework including an in-line non-verifiable single check valve assembly (suitable for backflow prevention of Fluid Category 2). Maximum working pressure 10.0 bar. Cold water use only.
Range of cold water in tank booster sets incorporating an ‘AB’ air gap, consisting of a GRP water storage cistern incorporating a float operated inlet valve, with a copper float and submersible pump or pumps (depending on model). The products incorporate an externally mounted stainless-steel manifold with servicing valve(s), expansion vessel, pressure gauge and a digital control panel. The pumps are connected to the external components via a discharge assembly of internal pipework including an in-line non-verifiable single check valve assembly (suitable for backflow prevention of Fluid Category 2). Maximum working pressure 10.0 bar. Cold water use only.
Range of pumps with stainless steel bodies and plastic impellors. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, shaft and outer sleeve. Maximum working pressures: T (oval flange): 16.0 bar. V (Victaullic & grooved), C (clamp flanges) & F (round flange) versions: 26.0 bar. Maximum operating temperature 100°C.
Range of multistage pumps with brass suction and discharge bodies, stainless steel housing, shaft and impeller, and EPDM ‘O’-rings and seals. Maximum working pressure: 6.0 bar (41491 & 41492 models) or 9.0 bar (41493 & 41494 models). Maximum operating temperature 65°C.
Range of shower handsets plastic bodies (various finishes) and EPDM ‘O’-rings. All models include a button on the shower face which alters the spray pattern. The product incorporates either a plastic strainer (26 050 & 26 530) or a stainless-steel strainer and a plastic flow regulator (26 051 & 26 531) on the inlet. Maximum operating temperature 60°C.
Range of ceiling mounted shower outlets. The inlet to the shower head incorporates a combined NBR gasket and stainless steel filter, as well as a plastic flow regulator which is located after an adjustable ball joint. Maximum operating temperature 60°C.
Range of overhead showers with brass and plastic bodies (various finishes - see models). The inlet incorporates a stainless-steel strainer and a plastic strainer. Products to be used with basic sets with brass bodies and EPDM O-rings. Open outlet use only
Non-metallic materials and components comply with BS6920 at 60°C
Range of filter type fixed ‘shower’ outlets and shower handsets with plastic bodies. Maximum operating temperature 45°C.
Range of shower handsets with brass bodies available in various styles and finishes. The inlets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of shower outlets incorporating brass bodies (various finishes) and NBR ‘O’-rings. Maximum operating temperature 85°C.
Range of filter type fixed ‘shower’ outlets and shower handsets with plastic bodies. Maximum operating temperature 45°C.
Range of filter type fixed ‘shower’ outlets and shower handsets with plastic bodies. Maximum operating temperature 45°C.
Range of shower outlets incorporating brass bodies (various finishes) and NBR ‘O’-rings. Maximum operating temperature 85°C.
Range of flow switches with plastic bodies. The VK308/10/15/20/25/32/40/50M and VKS08/10/15/20/25/32/40/50M prefix models are supplied with an inline brass adaptor. The VK305/306/309M and VKS05/06/09M prefix models are supplied with a brass adaptor for direct insertion into a pipe. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Range of flow sensors with brass or plastic bodies. Flow sensor type series VTY10 (plastic body, G3/4): Maximum working pressure 10.0 bar. Maximum operating temperature 85°C. Flow sensor type series VTY10 (plastic body, Quickfasten OD 22.5mm): Maximum working pressure 10.0 bar. Maximum operating temperature 70°C. Flow sensor type series VTY10 (brass body, G1/2): Maximum working pressure 16.0 bar. Maximum operating temperature 90°C.
Page 11 of 113
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.