Spring loaded resilient trim in-line check valve cartridge with plastic guide, stem and housing, stainless steel spring and EPDM ‘O’-rings. For insertion into specifically dimensioned bores. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of spring loaded, resilient trim, in-line check valve cartridges with plastic guide, stem and body with NBR or EPDM 'O'-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 60°C for model NV15/DN15-EPDM 31.0002.0. All other models have a maximum operating temperature of 85°C.
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating ceramic cartridge headwork with single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C
Single hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 70ºC.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator. Models 23472W-4-CP and 23475W-4-CP are supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60ºC.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, two hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members or non-rising spindle headworks with cross top operating members (model CR26 & CR26/501). The spout outlet incorporates a plastic flow straightener (models CR26 & CR26/501 do not incorporate a flow straightener). The products are supplied with plastic backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of wall mounted, two-hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic flow straightener. The inlet offset unions incorporate a servicing valve and the inlets to the taps incorporate a plastic flow restrictor. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of deck mounted two hole, double outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic disc (DLV305B, DLT305B) or rising spindle (CR305 “Bridge”, CR305/501 “Bridge” & GEO305) headworks. Models GEO305, DLT305B and DLV305B incorporate single lever type operating members. Models CR305 and CR305/501 incorporate cross top operating members. The products are supplied with plastic back nuts. Maximum operating pressure 10.0 bar. Maximum operating temperature 65°C.
Wall mounted two hole, double outlet (swivel) combination tap assembly (chromium plated brass) with quarter turn ceramic disc headworks and single lever type operating members. The product is supplied with plastic back nuts. Maximum operating pressure 10.0 bar. Maximum operating temperature 65°C.
Range of free-standing sanitary macerating disposal units. The units are fed via a flexible hose assembly. Flow is controlled by a solenoid valve and discharges via a type `AA` air gap. Maximum working pressure 10.0 bar. Cold water use only.
FloFit range of push fit fittings (polybutylene body) for use with Qual-Pex Barrier Pipe, Qual-PB polybutylene barrier pipe or copper tube. Above ground use only. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of copper solder ring fittings for use with copper tube. For above ground use only. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Range of copper end feed fittings for use with copper tube. For above and below ground use. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Range of flow measurement devices (DZR brass) bodies incorporating two test ports. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of inline circulating pumps with bronze bodies, plastic impeller and EPDM rubber seals. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Range of interlocked EPDM lined shower hoses assemblies with EPDM gaskets. Maximum operating temperature is 85°C. bar.
Range of wall mounted shower kit with brass bodies (various finishes) consisting of a shower rail with an overhead shower rose, incorporating a manual diverter to shower handset. Shower handset incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models AOOSCPUK and AOOSBKUK consist of just a shower handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted shower intake, having a brass body (chrome plated). The outlet incorporates a single check valve cartridge (however the complete assembly has not been tested to demonstrate it provides adequate backflow protection) Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Page 1 of 177
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.