‘G5 BC’ range of command centres that provide instant near boiling and chilled water (both filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The products are supplied with a filter cartridge. The products can also be supplied with a hot water booster and/or a venturi system to provide mains cold water combined with water from the hot water tank (see model). Maximum working pressure 5.0 bar. Maximum operating temperature 100˚C. Cold supply only.
‘G5 BCS’ range of command centres that provide instant near boiling, sparkling and chilled water (all filtered) via an electronically controlled tap (not supplied). Flow is controlled via a combination of solenoid valves and electronic pumps to the outlets. The products incorporate a pressure reducing valve (adjustable outlet pressure between 2.25 and 2.75 bar) on the supply to the carbonator unit. The carbonator inlet incorporates a non-return valve. The products are supplied with a filter cartridge. The products can also be supplied with a hot water booster and/or a venturi system to provide mains cold water combined with water from the hot water tank (see model). Maximum inlet supply pressure 5.0 bar. Maximum operating temperature 100˚C. Cold supply only.
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with a temporary filling loop which incorporates a combined isolation valve and double check valve assembly (suitable for backflow protection against Fluid Category 3), stainless steel braided EPDM lined flexible hose assembly and an isolation valve. The secondary circuit (DHW) incorporates a stainless-steel strainer. The primary circuit incorporates isolation valves on the flow and return. Maximum working pressures: DHW: 10.0 Bar CH:2.5 Bar Maximum operating Temperatures: DHW: 65.0°C CH: 85.0°C
‘DM900’ range of flow measuring devices with stainless steel bodies. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Hattersley M2000 range of flow measuring devices with stainless steel bodies. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.
Range of pressure, flow and temperature sensors. The VFI sensors have stainless steel bodies, all other models have plastic bodied sensors. The MFS and VFS models are supplied with a plastic (composite) or stainless-steel flow pipe. The VFI models are supplied with a stainless-steel flow pipe. The products can also be supplied with a range of fittings/end connections (see model and size). Maximum working pressures: ITS, LPS, RPS, MFS (composite flow pipe) and VFS (composite flow pipe) models: 24.0 bar. CPS models (added February 2024): 24.0 bar. DPS: Models with vent hole: 16.0 bar. All other models: 24.0 bar. MFS (stainless steel flow pipe) and MFS (stainless steel flow pipe): 30.0 bar. VFI non-flanged models: 30.0 bar. VFI flanged models: 30.0 bar or as per flange PN rating 16.0 bar or 25.0 bar (whichever is lower). Maximum operating temperature 99°C.
Permanent filling devices for primary heating and chilled water closed circuits in domestic and non-domestic premises. The mains and closed circuit system pressures are continuously checked by two pressure sensors and their differential monitored by microprocessors. If the mains pressure is adequate and there is a drop in system pressure, then the two solenoid valves operate to allow water into the system via the transfer chamber. At all other times the normally open solenoid valve drains the transfer chamber to waste, via tundish (meeting the requirements of an air gap to drain), and allowing air to be admitted via an automatic air vent to create an atmospheric disconnection across the transfer chamber. Stainless steel strainer on the inlet supply. Mikrofill 3: Maximum working pressure 5.0 Bar. Cold water use only. Mikrofill 3 Pro (72846): Maximum working pressure 9.0 Bar. Cold water use only.
Range wall mounted elbows (XX 1799 YY & XX E 1799 YY) and compression (XX 1749 YY & XX 1825 YY) fittings with brass bodies (various finishes, see models). Open outlet use only.
Non-metallic materials and components comply with BS6920 at 65°C
Range of circulator pumps with stainless steel bodies and a plastic impeller. All models are available with a plastic (composite) rotor can, the MAGNA1 range is also available with a stainless-steel rotor can in the DN32 flanged, threaded 1½ & 2” sizes only. The MAGMA3 models have a differential pressure sensor. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
CMBE range of horizontal multistage centrifugal booster pumps with stainless steel bodies and impellers and EPDM ‘O’-rings. All models include an expansion vessel, non-return valve, pressure gauge and sensor on the outlet. Maximum working pressure 10.0 bar. Cold water use only.
Range of vertical multistage pumps with either stainless-steel bodies (“N” versions) or cast iron bodies with a black electrodeposition coating (“G” versions), stainless-steel impellers, shaft and outer sleeve. Maximum working pressure: NKV32 & NKV45 models - 32.0 bar, NKV65 & NKV95 models - 25.0 bar. Max operating temperature: Stainless steel (“N” versions) - 100°C. Cast iron (“G” versions) - Cold water use only.
Range of vertical multistage pumps with either stainless-steel bodies (“N” versions) or cast iron bodies with a black electrodeposition coating (“G” versions), stainless-steel impellers, shaft and outer sleeve. Maximum working pressure: FGV30, FGV45 - 32.0 bar, FGV65, FGV95 - 25.0 bar. Max operating temperature: Stainless steel (“N” versions) - 100°C. Cast iron (“G” versions) - Cold water use only.
Range of shower outlets (brass or stainless-steel bodies – various finishes) incorporating EPDM O-rings. Maximum operating temperature 60.0°C
Non-metallic materials and components comply with BS6920 at 60°C
Wall mounted shower outlet (brass body – various finishes). The product is supplied with shower hose and handset that incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower handsets & overhead shower outlets with chromium plated plastic body. The inlets of the overhead shower outlets incorporate a stainless-steel strainer.
Non-metallic materials and components comply with BS6920 at 60°C
Range of overhead shower outlets with (brass bodies – various finishes), incorporating EPDM `O`-rings and a plastic strainer. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of overhead shower outlets with brass or stainless-steel bodies (various finishes - see model), with NBR ‘O’-rings. The inlet incorporates a stainless-steel strainer.
Non-metallic materials and components comply with BS6920 at 70°C
Range of shower arms and elbows (brass bodies – various finishes). Maximum operating temperature: (T2064W) - 95.0°C (T2062W, T2069W & T2069SW) - 85.0°C (T2066W) - 60°C
Wall mounted and ceiling mounted shower arms (chromium plated brass).
Non-metallic materials and components comply with BS6920 at 60°C
Range of overhead shower outlets with brass or stainless-steel bodies (various finishes - see model), with NBR ‘O’-rings. The inlet incorporates a stainless-steel strainer.
Non-metallic materials and components comply with BS6920 at 70°C
Page 99 of 214
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.