Range of copper solder ring fittings for use with EN 1057 copper tube. For above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of brass fittings with compression connections to be used with copper pipes EN 1057. For above ground use only. Maximum working pressure 6.0 bar. Maximum operating temperature 95°C.
‘Universal Transition Coupling (UTC)’ range of plastic compression fittings for use with the following pipe types and sizes: Stainless steel (manufactured to ASTM A554/ BS EN 10312): ¾”, 1” & 1¼”. Galvanised (EN 10255): ¾”, 1”, 1¼”, 1½” & 2”. Copper (BS EN 1057): 15mm, 22mm & 28mm. PVC (BS EN 1452): 20mm & 2”. ABS (BS 5391-1): 20mm, 25mm & 32mm. PE80 & PE100 pipe (to BS EN 12201): 20mm, 25mm, 32mm, 50mm & 63mm. For use above and below ground. Maximum working pressure 12.5 bar. Cold water use only.
Range of brass press fittings for use with copper pipe (manufactured to EN1057:2006 and +A1:2010 Seamless round copper tube, R250 half hard). Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of copper or brass (see model) end feed fittings for use with copper tube (manufactured to BS EN1057). Tap connectors incorporate Fibre/NBR washers. Male and female union adaptors incorporate a silicone gasket. Maximum working pressure using hard solder: 8mm to 28mm, ½” to 1” BSP (F) or (M), 1” straight cylinder union and captive nut ½” to ¾”: 25.0 bar, 35mm to 54mm, 1¼” to 2” BSP (F) or (M): 16.0 bar. Maximum working pressure using silver brazing alloy EN1044: 66.7mm to 108mm, 2½” to 4” BSP (F) or (M): 16.0 bar, 133mm to 219mm: 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of copper end feed fittings for use with copper tube to EN 1057. For above and below ground use. Maximum working pressure: 6mm-54mm 16.0bar, 64mm-108mm 10.0bar. Maximum operating temperature 85°C
‘Zip Aquapoint IV’ range of wall mounted directly heated unvented storage vessels (cased and insulated) incorporating an enamel lined cylinder and safety kit. The cylinder is factory fitted with a temperature and pressure relief valve (7.0 bar/90°C) and a drain valve. The product is supplied with an installation kit comprising of an expansion vessel, tundish and an inlet manifold incorporating a 6.0 bar expansion relief valve, an adjustable pressure reducing valve with stainless-steel strainer (adjustable between 2.7 and 3.3 bar, but pre-set at 3.0 bar), and a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). The compression connections of the installation kit are for use with copper pipe (Manufactured to EN 1057). Maximum working pressure 5.5 bar. Maximum operating temperature 70°C. Cold supply only.
Range of under-sink, electrically heated vented water heaters (cased and insulated). Maximum operating temperature 98˚C
Range of inline water meters with brass bodies (blue or red epoxy coating). The inlet incorporates a plastic strainer. Maximum working pressure 16.0 Bar. Maximum operating temperature 85.0°C.
Range of ultrasonic water meters with plastic bodies and plastic strainers at the inlets. Specific models (see models) incorporate an optional non return valve (not suitable for backflow protection). Maximum working pressure 16.0 Bar. Maximum operating temperature 90°C.
Range of accumulators. The brass vessel connector of the ACC-060-TNK, ACC-120-TNK and ACC-180-TNK models incorporates a plastic flow regulator. Maximum working pressure 8.6 bar. Cold water use only.
Range of ‘Tcontrols’ immersion heater elements incorporating brass or DZR heads with either a copper, stainless steel, alloy or titanium heating element and a black EPDM ‘O’-ring. Open outlet use only. Maximum operating temperature 99°C
‘Vari RS’ range of single, twin & triple cold water booster sets. The products incorporate one or more pumps, expansion vessels, isolation valves and non-return valves (not suitable for backflow protection). The twin and triple models include a suction and discharge manifold. Maximum working pressures - see model. Cold water use only.
Range of single, twin & triple cold water booster sets. The products incorporate one or more pumps, expansion vessels, isolation valves and non-return valves (not suitable for backflow protection). The twin and triple models include a suction and discharge manifold. Maximum working pressures - see model. Cold water use only.
Range of multistage centrifugal pumps with stainless steel impellers, intermediate chambers, shaft and outer sleeve. The Movitec VME models and VE/VSE models added May 2025 can also incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressures: Existing models: Comeo C models 10.0 bar, Movitec VM models with an oval flange or VME models with integral check valve 16.0 bar, All other Movitec VM models 25.0 bar. Models added May 2025: Movitec V/VS models with an oval flange or VE models with integral check valve 16.0 bar, All other Movitec V/VS models and Movitec HI/HSI models 25.0 bar. Maximum operating temperatures: Existing models: Comeo C and Movitec VME models with integral check valve 60°C, all other model variants 100°C. Models added May 2025: Movitec VE models with integral check valve 60°C, all other model variants 100°C.
Range of single and twin ended shower booster pumps with plastic bodies and plastic impellers. The inlets/outlets incorporate stainless steel braided EPDM lined flexible hose assemblies with isolation valves and stainless-steel strainers. The outlets incorporate approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. The Universal Twin models incorporate an expansion vessel. Maximum working pressure 1.5, 1.8, 2.0, 2.5, 2.6, 3.0 Bar (see model for more details). Maximum operating temperature: 60.0°C.
Shower handset with a stainless-steel body (various finishes - see model) and silicone nozzles. The inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 65°C.
Range of overhead shower and shower handsets with (brass or plastic bodies – various finishes), incorporating a stainless-steel strainer on the inlets. Open outlet use only Maximum operating temperature – 85°C.
Range of shower outlets, (plastic bodies - chrome plated) incorporating a plastic flow regulator. Products 24 540 xx0, 24 541 xx0, 24 550 xx0, 24 551 xx0 to be installed together with 24 573 180 Hansgrohe Raindance Alive Basic set. Maximum operating temperature 60°C. Open outlet use only.
Range of wall mounted shower shower heads (chrome plated brass) bodies. Maximum operating temperature 85°C. Open outlet use only.
Page 94 of 108
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.