#2107105

Range of WC dual flush drop valves comprising of a plastic body, silicone seal and an internal overflow. The valve is operated via a push button or lever assembly for either full or reduced flush. Cold water use only.

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not been verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
2107105
Note:
Open outlet use only.
Size:
2” BSP (M)
Marking:
Kohler and model number on valve body
Installation Requirements:
R001 R571
Expiry date:
31/07/2026
Model:
1190056 dual flush valve with any of the following actuators: 1278504-XX, 1367704-XX, 1215521-XX or 1199720-XX. 1409397 dual flush valve with 1409402-XX actuator. XX denotes the finish on the actuator, e.g. CP (chrome plating).
Product Images

Approval Holder:
Kohler (Thailand) Public Company Limited
Company Name
Kohler (Thailand) Public Company Limited
Address
16TH FLOOR JASMINE CITY BUILDING 2 SOI SUKHUMVIT 23.

View All Listings by this Company
Manufacturer:
Xiamen R&T Plumbing Technology Co.,Ltd
Company Name
Xiamen R&T Plumbing Technology Co.,Ltd
Address
No.18, Houxiang Road Haicang District Xiamen
Postcode
361022
Country
China
Phone
86-0592-3959422

View All Listings by this Company

Print This Approval


#2010374

Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The inlet and outlet of all circuits incorporates lever operated spherical valves with brass bodies. 274.xx9x.696 models all have the following additional items over the 274.xx1x.696 models: Heatmeter on the primary circuit, a flushing bypass between the primary and space heating circuits and a safety relief valve (set at 10.0 bar) on the cold supply to the heat exchanger of the domestic hot water circuit. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 9.5 bar and 60˚C. Secondary (space heating): 2.5 bar and 85˚C.

Section:
1350 Heat Exchangers
WRAS Approval Number:
2010374
Note:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with Schedule 2 paragraph 24to the Water Supply (Water Fittings) Regulations 1999.
Size:
¾” BSP (F)
Marking:
Taconova Group AG and other technical information on control panel. Pressure, temperature, WRAS, type and other technical information on inside cover.
Installation Requirements:
R001 R140 R360
Expiry date:
31/10/2025
Model:
274.2411.696 HL3000E 10/26. 274.2491.696 HL3000E 10/26. 274.2611.696 HL3000E 10/40. 274.2691.696 HL3000E 10/40. 274.4411.696 HL3000E 16/26. 274.4491.696 HL3000E 16/26. 274.4611.696 HL3000E 16/40. 274.4691.696 HL3000E 16/40. 274.6411.696 HL3000E 26/26. 274.6491.696 HL3000E 26/26. 274.6611.696 HL3000E 26/40. 274.6691.696 HL3000E 26/40. 274.6711.696 HL3000E 26/50. 274.6791.696 HL3000E 26/50. Models added April 2025: 274.2411.696 TacoTherm Dual ZEPTO SMART CONNECT 10/26. 274.2491.696 TacoTherm Dual ZEPTO SMART CONNECT 10/26. 274.2611.696 TacoTherm Dual ZEPTO SMART CONNECT 10/40. 274.2691.696 TacoTherm Dual ZEPTO SMART CONNECT 10/40. 274.4411.696 TacoTherm Dual ZEPTO SMART CONNECT 16/26. 274.4491.696 TacoTherm Dual ZEPTO SMART CONNECT 16/26. 274.4611.696 TacoTherm Dual ZEPTO SMART CONNECT 16/40. 274.4691.696 TacoTherm Dual ZEPTO SMART CONNECT 16/40. 274.6411.696 TacoTherm Dual ZEPTO SMART CONNECT 26/26. 274.6491.696 TacoTherm Dual ZEPTO SMART CONNECT 26/26. 274.6611.696 TacoTherm Dual ZEPTO SMART CONNECT 26/40. 274.6691.696 TacoTherm Dual ZEPTO SMART CONNECT 26/40. 274.6711.696 TacoTherm Dual ZEPTO SMART CONNECT 26/50. 274.6791.696 TacoTherm Dual ZEPTO SMART CONNECT 26/50. Where final part of code denotes the number of plates on the heat exchanger, e.g. 10/26, 10 = number of plates on the space heating circuit, 26 = the number of plates on the domestic hot water circuit.
Product Images

Approval Holder:
Taconova UK Limited
Company Name
Taconova UK Limited
Address
Technology Centre | Advanced Manufacturing Park | Brunel Way Rotherham
Postcode
S60 5WG
Country
UK

View All Listings by this Company
Manufacturer:
Taconova Production s.r.o.
Company Name
Taconova Production s.r.o.
Address
Nova UL. C 627, CZ-38232 Velesin, Czech Republic

View All Listings by this Company

Print This Approval


#2012362

Shower waste water heat recovery unit, consisting of a PVC-U waste pipe with an internal copper tube which provides a double wall separation between the waste water and cold mains supply. Maximum working pressure 10.0 bar. Maximum operating temperature 30°C.

Section:
1350 Heat Exchangers
Size:
½” BSP (F).
Marking:
Recoup logo, pipe ID outside wall, PVC-U 63x2.0, 16028740 kiwa, 5 16-01-19 11.40, PVC MET HERGERBUIKGRANTIE on adhesive label on outside wall.
Installation Requirements:
R001 R008
Expiry date:
31/12/2025
Model:
Recoup Pipe HEX: R-PHX-01 (2.1m length). Recoup Pipe HEX-Rd: R-PHX-03 (1.7m length).

Approval Holder:
Recoup Energy Solutions Ltd.
Company Name
Recoup Energy Solutions Ltd.
Address
Trumpeter House Trumpeter Rise Long Stratton
Postcode
NR15 2DY
Country
United Kingdom
Phone
+441379844010
General Email
ian@recoup.co.uk

View All Listings by this Company

Print This Approval


#2011037

Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. Incorporating a pressure relief valve and expansion vessel. Primary circuit has a maximum working pressure of 3.5 bar and operating temperature of 85°C. Secondary circuit has a maximum working pressure of 10.0 bar and operating temperature of 60°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2011037
Note:
A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Size:
½” BSP male inlet and outlet (DHW). ¾” BSP male inlet and outlet (CH).
Marking:
Lukey on adhesive label on front.
Installation Requirements:
R001 R140
Expiry date:
30/11/2025
Model:
Lukey solution HE (18kW CH & 26kW DHW). Lukey solution HE+ (18kW CH & 26kW DHW). Lukey solution HES+ (18kW CH & 26kW DHW). Lukey solution CBU (18kW CH & 26kW DHW). Beginning February 2021 the models will be named: Lukey 28 HE (18kW CH & 26kW DHW). Lukey 28 HE+ (18kW CH & 26kW DHW). Lukey 28 HES+ (18kW CH & 26kW DHW). Lukey 28 CBU (18kW CH & 26kW DHW).
Product Images

Approval Holder:
Lukey Cassette Boilers (UK) Ltd.
Company Name
Lukey Cassette Boilers (UK) Ltd.
Postcode
BH24 2BB

View All Listings by this Company
Manufacturer:
Lukey Cassette Boilers (UK) Ltd.
Company Name
Lukey Cassette Boilers (UK) Ltd.
Postcode
BH24 2BB

View All Listings by this Company

Print This Approval


#2011033

RINNAI range of wall mounted combination boilers.The unit incorporates a stainless-steel plate heat exchanger pressure relief valve set at 3.0 bar and an expansion vessel on the primary circuit. Maximum working pressure of primary circuit is 2.5 bar and secondary circuit is 10.0 bar. Maximum operating temperature 60˚C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2011033
Note:
Not supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Size:
Primary circuit: ¾” (M) BSP inlet and outlet. Secondary circuit: ½” (M) BSP inlet and outlet
Marking:
Rinnai on front. Rinnai, model and technical information on adhesive label on side of unit.
Installation Requirements:
R001 R140 R360
Expiry date:
30/11/2025
Model:
ZEN i24 Combi Boiler – REB-KBI2424FF. ZEN i29 Combi Boiler – REB-KBI2929FF. ZEN i34 Combi Boiler – REB-KBI3535FF.
Product Images

Approval Holder:
Rinnai UK Ltd
Company Name
Rinnai UK Ltd
Address
9 Christleton Court Manor Park Runcom
Postcode
WA7 18T
Phone
01928 531 870
General Email
info@rinnaiuk.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 10 of 178

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.