Directory Search Results

Print List

#240202703

Range of indirect and direct unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar @ 90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve pre-set at 3.0 bar, strainer, an expansion relief valve set at 6.0 bar and an approved check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided. Maximum working pressures: Primary: 3.0 Bar Secondary: 5.5 Bar Solar: 3.0 bar Maximum operating temperature 90.0°C

Section:
1890 Unvented Heating Apparatus
Size:
Primary circuit: 28mm compression Secondary circuit: 22mm compression Solar circuit: 22mm compression
Marking:
World Heat Ltd logo, model number, capacity, temperature and pressure and other technical information on adhesive label on cylinder.
Installation Requirements:
R001 R140 R360
Expiry date:
28/02/2029
Model:
120CLIMACYLSS2 – 120 Litre 550mm diameter with heat pump coil DN25 x 14M 150CLIMACYLSS2 – 150 Litre 550mm diameter with heat pump coil DN25 x 14M 180CLIMACYLSS3 – 180 Litre 550mm diameter with heat pump coil DN25 x 14M 210CLIMACYLSS3 – 210 Litre 550mm diameter with heat pump coil DN32 x 13M 250CLIMACYLSS3 – 250 Litre 550mm diameter with heat pump coil DN32 x 13M 300CLIMACYLSS3 – 300 Litre 550mm diameter with heat pump coil DN32 x 13M 120CLIMACYLSSTC12 – 120L 550mm diameter with heat pump & solar coils DN25 x 14M & DN20 x 7M 150CLIMACYLSSTC12 – 150L 550mm diameter with heat pump and solar coils DN25 x 14M & DN20 x 7M 180CLIMACYLSSTC13 – 180L 550mm diameter with heat pump and solar coils DN25 x 14M & DN20 x 7M 210CLIMACYLSSTC13 – 210L 550mm diameter with heat pump and solar coils DN32 x 13M 250CLIMACYLSSTC13 – 250L 550mm diameter with heat pump and solar coils DN32 x 13M 300CLIMACYLSSTC13 – 300L 550mm diameter with heat pump and solar coils DN32 x 13M 120TCSFLOW – 120L 550mm diameter with boiler and solar coils 2 x DN20 x 7M 150TCSFLOW – 150L 550mm diameter with boiler and solar coils DN20 x 8M & DN20 x 7M 180TCSFLOW – 180L 550mm diameter with boiler and solar coils DN20 x 8M & DN20 x 7M 210TCSFLOW – 210L 550mm diameter with boiler and solar coils DN25 x 10M & DN20 x 7M 250TCSFLOW – 250L 550mm diameter with boiler and solar coils DN25 x 10M & DN20 x 7M 300TCSFLOW – 300L 550mm diameter with boiler and solar coils DN25 x 14M & DN20 x 7M 120DSSFLOW – 120L 550mm diameter direct with no coils and 2 x immersion heaters 150DSSFLOW – 150L 550mm diameter direct with no coils and 2 x immersion heaters 180DSSFLOW – 180L 550mm diameter direct with no coils and 2 x immersion heaters 210DSSFLOW – 210L 550mm diameter direct with no coils and 2 x immersion heaters 250DSSFLOW – 250L 550mm diameter direct with no coils and 2 x immersion heaters 300DSSFLOW – 300L 550mm diameter direct with no coils and 2 x immersion heaters 120ISSFLOW – 120L 550mm diameter with boiler coil DN20 x 7M 150ISSFLOW – 150L 550mm diameter with boiler coil DN20 x 8M 180ISSFLOW – 180L 550mm diameter with boiler coil DN20 x 8M 210ISSFLOW – 210L 550mm diameter with boiler coil DN25 x 10M 250ISSFLOW – 250L 550mm diameter with boiler coil DN25 x 10M 300ISSFLOW – 300L 550mm diameter with boiler coil DN25 x 14M
Product Images

Approval Holder:
World heat Ltd
Company Name
World heat Ltd
Postcode
SK16 4RN
Country
United Kingdom
Phone
0161 343 8610
General Email
sales@whcylinders.co.uk

View All Listings by this Company
Manufacturer:
World heat Ltd
Company Name
World heat Ltd
Postcode
SK16 4RN
Country
United Kingdom
Phone
0161 343 8610
General Email
sales@whcylinders.co.uk

View All Listings by this Company

Print This Approval


#240402711

Range of flow control valves with epoxy coated ductile iron bodies. Auxiliary components include a needle valve, pressure reducing pilot valve and isolation valves. Maximum supply pressure 16.0 bar. Outlet pressure setting is adjustable in the range 0.6 to 1.2 bar. Maximum operating temperature 65°C.

Section:
2165 Valves
Section Subtitle:
Flow control, pilot operated control.
WRAS Approval Number:
240402711
Size:
DN40 up to DN1400 flange inlet and outlet.
Marking:
Cla-Val, flow arrow, PN and DN on body. Cla-Val, flow arrow, PN, DN and model number on data plate on inlet flange.
Installation Requirements:
R001
Expiry date:
30/04/2029
Model:
NG1E-40-01KCOS (DN 50 to DN600) 40-G1E-01KCOS (DN40 to DN400) NG1E-40-01 Reduced port valve 50mm – 1400mm 40-G1E-01 Full port valve 40mm – 1400mm Note: 40-G1E-01 / NG1E-40-01 – where 1 means the main valve body is ductile iron. We do not include this in our marketing literature/drawings as it is not considered relevant. Description of suffix codes Where: - ‘K’ = Generic prefix for any subsequent letters - standard for all water duty valves ‘C’ = Internally and Externally epoxy coated - standard for all water duty valves ‘O’ = Stainless steel studs and washers for the main valve -standard for all water duty valves ‘S’ = Stainless steel seat and Disc guides - standard for all water duty valves
Product Images

Approval Holder:
Cla-Val UK Ltd.
Company Name
Cla-Val UK Ltd.
Address
Dainton House 107 Goods Station Road Tunbridge Wells
Postcode
TN1 2DR
Country
United Kingdom
Phone
01892 514400
General Email
liam.kent@cla-val.co.uk

View All Listings by this Company

Print This Approval


#240402712

Range of pilot operated basic valves, main body only, with epoxy coated ductile iron bodies. Maximum operating pressure 16.0 bar. Maximum operating temperature 65°C.

Section:
2165 Valves
Section Subtitle:
Flow control, pilot operated control.
WRAS Approval Number:
240402712
Size:
DN40 up to DN1400 flanged inlet and outlet (see models)
Marking:
Cla-Val, flow arrow, DN and PN on body. Cla-Val, flow arrow, DN, PN and model number on data plate on flange.
Installation Requirements:
R001
Expiry date:
30/04/2029
Model:
NG1E 100-01KCOS (DN50 to DN600) TYTAN-S-100-701/KCOS (DN600 to DN800) TYTAN-M-100-701/KCOS (DN900 to DN1000) TYTAN-L-100-701/KCOS (DN1200 to DN1400) 100-G1E-01KCOS (DN40 to DN400) Description of suffix codes, where: ‘K’ = Generic prefix for any subsequent letters ‘C’ = Internally and Externally epoxy coated ‘O’ = Stainless steel studs and washers for the main valve ‘S’ = Stainless steel seat and Disc guides
Product Images

Approval Holder:
Cla-Val UK Ltd.
Company Name
Cla-Val UK Ltd.
Address
Dainton House 107 Goods Station Road Tunbridge Wells
Postcode
TN1 2DR
Country
United Kingdom
Phone
01892 514400
General Email
liam.kent@cla-val.co.uk

View All Listings by this Company

Print This Approval


#2310146

Range of non-return, swing gate valves with gunmetal bronze bodies. Maximum working pressure 20.0 bar.

Non-metallic materials and components comply with BS6920 at 85°C

Section:
2188 Valves
Section Subtitle:
Non-return, swing gate, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should be made to `Backflow Prevention Devices`.
WRAS Approval Number:
2310146
Marking:
Company Logo, size, PN and flow arrow on body. Tecofi France, PN, DN and Temp on data plate.
Installation Requirements:
R001
Expiry date:
31/10/2028
Model:
CB2143W range: DN15 – ½” BSP female inlet/outlet DN20 – ¾” BSP female inlet/outlet DN25 – 1” BSP female inlet/outlet DN32 – 1 ¼” BSP female inlet/outlet DN40 – 1 ½” BSP female inlet/outlet DN50 – 2” BSP female inlet/outlet

Approval Holder:
TECOFI
Company Name
TECOFI
Address
2 Rue Barthélemy Thimonier ZAC Everest Lyon
Postcode
69740
Country
France
General Email
j.ortega@tecofi.fr

View All Listings by this Company

Print This Approval


#240104702

Range of pressure reducing valves with a DZR brass body, stainless steel strainer and EPDM membrane. Maximum inlet supply pressure 25.0 bar. Outlet pressure in the range of 1.0-6.0 bar. Maximum operating temperature 80°C.

Section:
2200 Valves
Section Subtitle:
Pressure reducing.
WRAS Approval Number:
240104702
Size:
½” - 2” BSP (M).
Marking:
Brymec on cap. Brymec, flow arrow, size and CR on body.
Installation Requirements:
R001
Expiry date:
31/01/2029
Model:
Brymec Ultra Pressure Reducing Valve range (c/w unions): 36212, 36213, 36214, 36215, 36216, 36217.
Product Images

Approval Holder:
Brymec Ltd
Company Name
Brymec Ltd
Address
Redlands , Coulsdon, Surrey
Postcode
CR5 2HT
Country
United Kingdom
General Email
Jeremy.douglas@brymec.com

View All Listings by this Company

Print This Approval


#240204007

Range of servicing valves with chrome plated brass balls and brass bodies (chrome plated) with either lever operating or butterfly operating members (see models). Compression connection to be used with copper pipe EN1057. Maximum working pressure 25.0 bar. Maximum operating temperature 85ºC.

Section:
2260 Valves
Section Subtitle:
Spherical, metal.
WRAS Approval Number:
240204007
Size:
see model
Marking:
JMING, PN, size and date of batch on body, JMING, WRAS, pressure and temperature rating on lever operating member
Installation Requirements:
R001
Expiry date:
28/02/2029
Model:
JMYG-049 – 15mm compression – lever handle JMYG-050 – 22mm compression – lever handle JMYG-051 – 28mm compression – lever handle JMYG-052 – 14.7mm compression – lever handle JMYG-053 – 21mm compression – lever handle JMYG-054 – 27.4mm compression – lever handle JMYG-076 – 15mm compression – Red butterfly handle JMYG-077 – 22mm compression – Red butterfly handle JMYG-078 – 28mm compression – Red butterfly handle JMYG-079 – 15mm compression – Blue butterfly handle JMYG-080 – 22mm compression – Blue butterfly handle JMYG-081 – 28mm compression – Blue butterfly handle

Approval Holder:
Ningbo Jiaming Metal Products Co. Ltd.
Company Name
Ningbo Jiaming Metal Products Co. Ltd.
Address
No.158 JinCi Road Hangzhou Wan New Zone Cixi City
Country
Zhejiang
Phone
+86-574-63575000

View All Listings by this Company
Manufacturer:
Ningbo Jiaming Metal Products Co. Ltd.
Company Name
Ningbo Jiaming Metal Products Co. Ltd.
Address
No.158 JinCi Road Hangzhou Wan New Zone Cixi City
Country
Zhejiang
Phone
+86-574-63575000

View All Listings by this Company

Print This Approval


#240102084

Range of lever or butterfly operated spherical valves with brass or nickel plate bodies and ball. Maximum working pressure: Various – see model section. Maximum operating temperature 99.0°C

Section:
2260 Valves
Section Subtitle:
Spherical, metal.
WRAS Approval Number:
240102084
Size:
See models – All models BSP (F) x (F)
Marking:
IDC logo, PN, DN & size on body
Installation Requirements:
R001
Expiry date:
31/01/2029
Model:
40.0 Bar: BVAL400140 (BLUE HANDLE) ¼” BVAL400141 (RED HANDLE): ¼” BVAL400120 (BLUE HANDLE) ⅜” BVAL400121 (RED HANDLE): ⅜” BVAL400000 (RED HANDLE) ½” BVAL400001 (BLUE HANDLE) ½” BVAL400010 (BLUE HANDLE) ¾” BVAL400011 (RED HANDLE): ¾” BVAL400020 (BLUE HANDLE) 1” BVAL400021 (RED HANDLE): 1” BVAL400030 (BLUE HANDLE) 1¼” BVAL400031 (RED HANDLE): 1¼” BVAL400040 (BLUE HANDLE) BVAL400041 (RED HANDLE): 1½” BVAL400050 (BLUE HANDLE) 2” BVAL400051 (RED HANDLE): 2” BVAL400130: ½”- PN 40 BVAL400131: 2½” - PN25

Approval Holder:
RELIANCE WORLDWIDE CORPORATION (UK) LTD
Company Name
RELIANCE WORLDWIDE CORPORATION (UK) LTD
Address
HORTON ROAD WEST DRAYTON
Postcode
UB7 8JL
Country
United Kingdom
Phone
+44 7730 052060
General Email
PETER.LANCASTER@RWC.COM

View All Listings by this Company

Print This Approval


#240402012

Range of lever operated spherical valves with DZR brass or stainless-steel bodies and ball. Models beginning with ‘GP’ and ‘GPH’ are for use with copper pipes (manufactured to EN 1057). Models beginning with ‘GPMS’ and ‘GPHS’ are for use with stainless steel (SS316L) pipe (manufactured to EN 10312). Maximum working pressure 25.0 bar. Maximum operating temperature 85°C

Section:
2260 Valves
Section Subtitle:
Spherical, metal.
WRAS Approval Number:
240402012
Size:
15 – 54mm crimped connections. ½” – 2” BSP (F).
Marking:
GP, DN, PN and CR or 316L (depending on body material) on body. GUTPRESS on operating member.
Installation Requirements:
R001
Expiry date:
30/04/2029
Model:
GP60015PP - 15mmx15mm GP60022PP - 22mmx22mm GP60028PP - 28mmx28mm GP60035PP - 35mmx35mm GP60042PP - 42mmx42mm GP60054PP - 54mmx54mm GP60015012PF - 15mmxG½” GP60022034PF- 22mmxG¾” GP60028100PF - 28mmxG1” GP60035114PF - 35mmxG1¼” GP60042112PF - 42mmxG1½” GP60054200PF - 54mmxG2” GPMS6001515PP - 15mmx15mm GPMS6001818PP - 18mmx18mm GPMS6002222PP - 22mmx22mm GPMS6002828PP - 28mmx28mm GPMS6003535PP- 35mmx35mm GPMS6004242PP - 42mmx42mm GPMS6005454PP - 54mmx54mm GPH60015PP - 15mmx15mm GPH60018PP - 18mmx18mm GPH60022PP - 22mmx22mm GPH60028PP - 28mmx28mm GPH60035PP-35mmx35mm GPH60042PP - 42mmx42mm GPH60054PP - 54mmx54mm GPHS60015PP - 15mmx15mm GPHS60018PP - 18mmx18mm GPHS60022PP - 22mmx22mm GPHS60028PP - 28mmx28mm GPHS60035PP - 35mmx35mm GPHS60042PP - 42mmx42mm GPHS60054PP - 54mmx54mm
Product Images

Approval Holder:
Taizhou Double Winners Copper Co., Ltd
Company Name
Taizhou Double Winners Copper Co., Ltd
Address
#2‐902, Z Center, No. 185 Wenxue Road, Jiaojiang, Taizhou, 31800, Zhejiang, China

View All Listings by this Company

Print This Approval


#240402710

Range of motorised position pilot operated control valves with epoxy coated ductile iron bodies and stainless-steel pipework and fittings. Maximum operating pressure 16.0 bar. Maximum operating temperature 65°C.

Section:
2347 Valves
Section Subtitle:
Special combination assemblies, pilot operated control.
WRAS Approval Number:
240402710
Size:
DN40 up to DN1400 flanged inlet and outlet.
Marking:
Cla-Val, flow arrow, DN, PN and model number on data plate on flange.
Installation Requirements:
R001
Expiry date:
30/04/2029
Model:
NG1E-138-L21KCOS (DN50 to DN600) 138-G1E-L21KCOS (DN40 to DN400) NG1E-138-L721KCOS TYTAN S (DN600 to DN800) NG1E-138-L721KCOS TYTAN M (DN900 to DN1000) NG1E-138-L721KCOS TYTAN L (DN1200 to DN1400) All valves up to DN600 have the option to be fitted with a manual operator. For sizes above 600mm, this is fitted as standard. Description of suffix codes, where: ‘K’ = Generic prefix for any subsequent letters ‘C’ = Internally and Externally epoxy coated ‘O’ = Stainless steel studs and washers for the main valve ‘S’ = Stainless steel seat and Disc guides
Product Images

Approval Holder:
Cla-Val UK Ltd.
Company Name
Cla-Val UK Ltd.
Address
Dainton House 107 Goods Station Road Tunbridge Wells
Postcode
TN1 2DR
Country
United Kingdom
Phone
01892 514400
General Email
liam.kent@cla-val.co.uk

View All Listings by this Company

Print This Approval


#240102706

Range of bedpan washing & disinfection machines. The flow is controlled by a solenoid valve and discharged via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure - See models Maximum operating temperature - 90 °C

Section:
2360 Washing Machines
Section Subtitle:
Bedpan and disinfecting. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
WRAS Approval Number:
240102706
Size:
½” BSP (M)
Marking:
Stanbridge on control panel. Stanbridge, serial number and company information on date plate on front panel.
Installation Requirements:
R001
Expiry date:
31/01/2029
Model:
CS1 ST – 000101 – 4.14 Bar CS2 ST – 000-201 – 4.14 Bar CS3 ST – 000-301 – 4.14 Bar CS3 HD – 000-302 – 8.00 Bar Slimline – 000-401 – 8.00 Bar
Product Images

Approval Holder:
Stanbridge Ltd
Company Name
Stanbridge Ltd
Address
Unit 78, Powder Mill Lane Quester Estate Dartford
Postcode
DA1 1JA
Country
United Kingdom
Phone
+44 (0)1689 806500
General Email
claire@stanbridge.co.uk

View All Listings by this Company
Manufacturer:
Stanbridge Ltd
Company Name
Stanbridge Ltd
Address
Unit 78, Powder Mill Lane Quester Estate Dartford
Postcode
DA1 1JA
Country
United Kingdom
Phone
+44 (0)1689 806500
General Email
claire@stanbridge.co.uk

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 82 of 120

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.