Range of hose assemblies. Models B0301-148036-000 & B0301-148038-000 comprise of a spherical valve, stainless-steel braided EPDM lined flexible hose and double check valve assembly (suitable for backflow protection against fluid category 3). Model B0301-148037-000 comprises of a double check valve assembly (suitable for backflow protection against fluid category 3), stainless-steel braided EPDM lined flexible hose and ‘T’ type spherical valve. Maximum working pressure 10.0 bar. Cold water use only.
Hydraulic circuit used to control the water path within the heating and sanitary boiler, with plastic body incorporating filter, flow regulator, plate heat exchanger and EPDM O-rings. Maximum working pressure 7.0 bar. Maximum operating temperature 85°C.
Isolation valve, stainless-steel braided EPDM lined flexible hose assembly and a non-verifiable double check valve assembly, verified by test (suitable for backflow protection against fluid category 3). For use with copper pipe (manufactured to EN 1057). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Three hole, basic rough-in set with a brass body, incorporating EPDM O-ring seals. The product is supplied with a shower hose and a stainless steel braided, silicone lined flexible connecting hose. Maximum working pressure 10.0 Bar
Non-metallic materials and components comply with BS6920 at 70°C
‘SCALA1’ range of booster pumps with plastic bodies, plastic impellers, EPDM and NBR ‘O’-rings. The product incorporates a non-return valve. Maximum working pressure 8.0 bar. Cold water use only.
Range of multistage centrifugal pumps, with stainless steel bodies (CRN models) or black coloured cataphoretic electrodeposition coated cast iron bodies (CR models), stainless steel sleeve and impellers. The products can be supplied with or without a sensor. Maximum working pressures (no. of stages in brackets): CR/CRN 95 (1-5): 16.0 bar. CR/CRN 95 (6-8): 25.0 bar. CRN 95 (9-12): 40.0 bar. CR/CRN 125 (1-4): 16.0 bar. CR 125 (5): 25.0 bar. CRN 125 (6-7): 25.0 bar. CRN 125 (8-12): 40.0 bar. CR 155 (1-4): 16.0 bar. CRN 155 (1-4): 16.0 bar. CRN 155 (5-6): 25.0 bar. CRN 155 (7-11): 40.0 bar. CR/CRN 185 (1-3): 16.0 bar. CR/CRN 185 (4-5): 25.0 bar. CR/CRN 185 (6-8): 40.0 bar. CR/CRN 215 (1-3): 16.0 bar. CR/CRN 215 (4-5): 25.0 bar. CR/CRN 215 (6-7): 40.0 bar. CR/CRN 255 (1-3): 16.0 bar. CR/CRN 255 (3-4): 25.0 bar. CR/CRN 255 (5-6): 40.0 bar. When a sensor is incorporated the maximum working pressure is as follows: 25.0 bar with either the IPS44 or VTU sensor, (unless they are used on a pump with a maximum working pressure of 16.0 bar, in this instance the lesser pressure applies). The MBS3000 sensor can be used on all models, the pump maximum working pressure applies. Cold water use only.
Range of two stage horizontal water pumps with plastic bodies, stainless steel impellers and shaft, incorporating EPDM gaskets and seals. The products also incorporate a non-return valve (not suitable for backflow protection) and an shock arrestor expansion vessel. Maximum working pressure 1.8 bar. Cold water use only.
Horizontal 5 stage pump with stainless steel body, stainless steel impellers, EPDM and silicone ‘O’-rings. Maximum working pressure 6.2 Bar. BS6920 40°C.
Range of vertical multistage pumps with either stainless-steel bodies or cast-iron bodies with a black epoxy powder coating, stainless-steel impellers, shaft and outer sleeve, EPDM ‘O’-rings and a silicon carbide + EPDM shaft seal. Maximum working pressure 25.0 bar. Maximum operating temperature 90°C.
Range of overhead shower outlets with chromium plated plastic bodies. The inlets incorporate combined EPDM washers and stainless-steel strainers. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of wall mounted shower arms, (brass bodies - various finishes) incorporating EPDM ‘O’- rings.
Non-metallic materials and components comply with BS6920 at 85°C
Range of wall mounted, overhead shower outlets with brass bodies (chromium plated), EPDM o-rings, fibre gasket and strainer at the shower head inlets. Multiple spray patterns available which is controlled via solenoid valve and a touch sensor. Product incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Open outlet use only. Maximum working temperature 60°C.
Shower handset, chrome plated plastic incorporating EPDM ‘O’-rings.. Maximum operating temperature 60°C
Ceiling mounted shower outlet with chromium plated brass body, EPDM o-rings and a plastic flow regulator at the inlet. Maximum operating temperature 60°C
Shower kit comprising of a plastic shower handset incorporating a plastic flow restrictor, PVC lined shower hose that incorporates EPDM washers and riser rail assembly, available in various finishes.
Non-metallic materials and components comply with BS6920 at 65°C
Range of shower handsets with plastic bodies (chrome plated). The overhead showers incorporate a combined EPDM washer and stainless-steel strainer on the inlet. Maximum operating temperature 65°C.
Range of in-line Y-pattern strainers with blue epoxy coated ductile iron bodies, EPDM ‘O’-rings and a stainless-steel mesh. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of ‘Y’- pattern strainers with brass bodies incorporating stainless steel filters and EPDM ‘O’-rings. M profile press connection to be used with copper pipe EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Flow switch with a black plastic (nylon) body and an EPDM ‘O’-ring. The product incorporates a plastic filter on the inlet. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of nylon braided hoses with TPSiV inner liner and brass end connections incorporating EPDM washers.Open outlet use only.
Non-metallic materials and components comply with BS6920 at 65°C
Page 69 of 110
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.