Range of single hole, single outlet (fixed) combination tap assemblies (brass body - various finishes) incorporating a ceramic cartridge headwork with single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar. Maximum operating temperature 60.0°C.
Single hole, single outlet (swivel) combination tap assemblies (brass bodies – various finishes), incorporating a ceramic cartridge, non-rising spindle or quarter turn ceramic disc headwork with either a single lever, cross top or dome type operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of single hole, single outlet (swivel) combination tap assemblies (various finishes) with under counter boiling water unit (vented via the spout outlet) and in-line water filter (on instantaneous hot water supply only), incorporating self-closing headworks with a single lever operating members and the spout outlet incorporating stainless steel strainers. Models F-HC1100C-1 and F-HC1100BR-1 also incorporate non-return valves. Not suitable for backflow protection. Maximum working pressure 8.6 Bar. Maximum operating temperature 85°C.
Single hole, single outlet (swivel) combination tap assembly (chrome plated brass), incorporating quarter turn ceramic disk headwork’s with single lever operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and cross top operating members. Products are supplied with lever type pop up wastes. Maximum working pressure 10.0 Bar. Maximum operating temperature 60.0°C.
Wall mounted two-hole, single outlet concealed combination tap assembly (brass body – various finished trim sets), incorporating a ceramic cartridge headwork with a single lever type operating member. The spout outlet incorporates a aerator. Maximum working pressure 10 bar. Maximum operating temperature 60°C
Wall mounted, two-hole, single outlet (fixed) combination tap assembly (brass bodies – various finishes) incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C
Wall mounted two-hole, single outlet (fixed) combination tap assemblies with (brass bodies – various finishes), incorporating a ceramic cartridge headwork and single lever operating member. The spout outlets incorporate a plastic aerator and flow straightener. Maximum operating pressure 10 bar. Maximum operating temperature 65°C
Range of wall mounted, two-hole, single outlet (fixed) combination tap assemblies with (brass bodies - various finishes), incorporating ceramic cartridge headworks and single lever type operating member. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 Bar. Maximum operating temperature 60.0°C
Two-hole, single outlet fixed combination tap assembly (chrome plated brass body), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal back nuts. Maximum working pressure 10 bar. Maximum operating temperature 65°C.
Range of wall mounted, two-hole, single outlet, (fixed), combination tap assemblies, (brass bodies – various finishes), incorporating a ceramic cartridge headworks with single lever operating members. The spout outlets incorporate plastic aerators. Maximum operating pressure 10 bar. Maximum operating temperature 60°C 13 623 180 rough-in set does not form as part of this approval.
Wall mounted two hole, single outlet (fixed) combination tap assembly (chromium plated brass) incorporating a sequential headwork controlling both flow and temperature using a single lever operating member. Inlets incorporate an isolation valve, stainless steel strainers and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. HTMWMRS is supplied with a removable spout. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Wall mounted, three-hole, single outlet (fixed) combination tap assemblies (brass body - various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 Bar. Maximum operating temperature 60.0°C.
Range of Wall mounted, four-hole, single outlet (swivel) combination tap assemblies (Various Finishes). Incorporating a ceramic cartridge headwork controlling the flow to the shower handset and two quarter turn ceramic disc headworks controlling the flow to the spout outlet, all with single lever operating members. The spout outlets incorporate a plastic aerator. The inlet to the shower handsets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of combined bath filler, waste and overflow assemblies (in various finishes with a plastic body). The outlets incorporate plastic aerator. Maximum operating temperature 60°C
Range of wall mounted spout outlets (brass bodies – various finishes) incorporating NBR O-rings and plastic aerators. Maximum working pressure 10.0 Bar. Maximum operating temperature 60°C
Range of wall mounted or floor standing spout outlets (fixed or swivel - see model in various finishes). All models incorporate a plastic flow straightener, except for the 93-Floor Mounted Bath Filler which has a plastic aerator.
Non-metallic materials and components comply with BS6920 at 60°C
Range of chemical dosing equipment. The outlet of the injector incorporates a connection for injection of chemicals via venturi action. Max operating pressure 5.9 bar. Cold water only
Range of cylindrical or tubular expansion vessels with epoxy coated carbon steel bodies. Maximum working pressure 8.0 bar. Maximum operating temperature 65°C
Range of expansion vessels with butyl membranes. Maximum working pressure 8.0, 10.0, 16.0 or 20.0 bar (please refer to model). Maximum operating temperature 70 or 100°C (please refer to model).
Page 67 of 124
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.