'PRO V200'. Site applied, two-part (supplied with internal mixing nozzle so no manual mixing required), brown coloured chemical anchor resin. Apply as per manufacturer's instructions 'Version 7', dated '18/05/2022'. Cure for 4 days@5°C. For use with water up to 23°C. For use only as a resin anchor having been tested at a reduced surface area to volume ratio of 1,000mm² per 1 litre of water. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'DL8099F Gaskets and 'O' rings'. Black coloured, compression moulded EPDM gaskets and 'O' rings. Shore hardness 70. Gaskets have an in-radius size of 1.5mm. 'O' rings have an in-radius size of 1.45mm. For use with water up to 85°C.
'Corirubber 4070 gaskets'. Black coloured, compression moulded EPDM rubber gaskets. Shore hardness 70. Tested in-radius size between 1.53mm & 4.01mm. For use with water up to 23°C.
'ergo 4207 (yellow coloured), 4205 (white coloured) & 4453 (green coloured)'. Anaerobic adhesives to be applied cured in strict accordance with the manufacturer's instructions. For use with water up to 85°C.
Range of electronic, touch free, wall-mounted taps (chromium plated brass. The flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 Bar Maximum operating temperature 65.0°C
Range of BS1212-4 (2016) compact type float operated valves for WC flushing cisterns, with either bottom entry (A28-06 XXX models) or side entry (A28-06 side). The inlet incorporates a plastic strainer. Maximum working pressure 10.0 Bar Cold Water Use Only
Bottom entry BS1212-4 (2016) compact type float operated valves for use with WC flushing cisterns. The inlet incorporates a strainer. Maximum working pressure 10.0 bar. Cold water use only.
Floor mounted, single outlet (fixed) combination tap assembly (chrome plated brass) incorporating a ceramic cartridge headwork with a single lever operating member and a self-cancelling diverter to shower outlet with a Type HC backflow protection device (verified by test - suitable for backflow protection against Fluid Category 3)he shower outlet incorporates a single check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator, and the product is supplied with an approved shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of shower kits with a shower hose, handset and shower rail. Maximum operating temperature 60 °C. Open outlet use only.
Range of spring loaded single check valve cartridges comprising of a POM body and cap, stainless steel spring and EPDM gasket and O-rings. Max working pressure 10 bar. Max operating temperature 85°C.
Page 557 of 620
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.