Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The inlet hoses incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The cold only inlet hoses incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assemblies (Chromium plated or brushed nickel finish), incorporating quarter turn ceramic disk headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. Supplied with approved single check valves, verified by test (suitable for backflow protection against Fluid Category 2) with integral servicing valve for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assemblies (chrome plated brass), incorporating quarter turn ceramic disc headwork. The spout outlet incorporates a plastic flow straightener and the product is supplied with single check valve assemblies (verified by test as suitable for backflow protection against Fluid Category 2) with integral servicing valve for both inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Single hole, single outlet (swivel) combination tap assemblies (chrome plated brass body), incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates a plastic aerator. Inlets incorporate isolation valves that incorporate single check valve cartridges, however, the complete assembly has not been fully tested to demonstrate it provides backflow protection. Maximum static pressure 5 bar. Maximum operating temperature 60°C
Single hole, double outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and dome operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, double outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and dome operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted two hole, single outlet (fixed) combination tap assembly (brass body, various finishes), incorporating ceramic cartridge headwork and single lever operating member. The spout incorporates a plastic aerator. Maximum working pressure: 5.0 bar. Maximum operating temperature: 60°C.
Range of wall mounted two-hole, single outlet (fixed) combination tap assemblies (brass bodies with various finishes) incorporating a ceramic cartridge headwork with single lever operating member. The spout outlets incorporate an aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted two-hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes). Incorporating a ceramic cartridge headwork with dome type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure; 10 Bar Maximum operating temperature 65°C
Range of two-hole, double outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic discs headworks and single lever or dome operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of wall mounted three-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes). Incorporating quarter turn ceramic disc headworks and various operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C
SuperFlow MCPA, MCMA & MCUA ranges of expansion vessels. Maximum working pressures: MCPA Series = 10.0 bar, MCMA Series = 16.0 bar, MCUA Series = 25.0 bar. Maximum operating temperature 65°C.
Inline filter with plastic body. Maximum working pressure 5.0 bar. Cold water use only.
Range of in-line carbon block water filters and housings with polypropylene bodies. Maximum working pressure 8.0 bar. Cold water use only.
Range of brass press fittings (TH and U crimp profiles) for use with RIIFO B1 PEX/AL/PEX multilayer pipe. Maximum working pressure: 10 bar Maximum operating temperature: 95 °C
Page 514 of 555
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.