Range of ultraviolet disinfection units with stainless-steel bodies. Maximum working pressure 16.0 bar. Cold water use only.
'ELECTROLINE ES 1212'. Factory applied, white coloured, two-component, solvent -free epoxy coating. Mix base and hardener in a 2:1 volume ratio and apply as per manufacturer's TDS 'ECL/ TDS / ES1212', issue date '2-Feb-14', version '0'. Cure for 7 days@30°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
‘NMSP2104 M & ER2104A01SM'. The following coatings were added to the approval in March 2025: ER2209A01SC, ER2252A01SC, ER2259A01SC & ER2260A01SC. Factory applied, blue coloured, porcelain (vitreous) enamel coatings. Apply as per manufacturer’s user manual 'PEM 38', edition '01' dated '14/10/2020'. Cure for 5 minutes@840°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘PMSP5099-M & EP5099D01SC'. Factory applied, blue coloured, porcelain (vitreous) enamel coatings. Apply as per manufacturer’s user manual 'PEM 37', edition '01' dated '14/10/2020'. Cure for 5 minutes@840°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'PRIMGREEN® ENDURANCE & Primgreen LAT 12035' primers for use with 'RILSAN® PA11 T BLUE 7444 MAC (16293), PA11 T GREY 5161 MAC (17203), PA11 T WHITE 1488 AC (17219) & PA11 T BLACK 7450 AC (17185)' coatings. Factory applied primers and powder coatings. The piece to be coated is to be pre-heated to 330°C for 10 minutes, the primer and coating applied in accordance with user instructions 'Dircom - 4418E/05.2015/20' and then cured for 10 minutes@330°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Sikagard® 1816 (formerly known MasterProtect® 1816)'. Site applied, grey coloured (once applied), two-component Epoxy polysulfide coating. Mix parts A & B in a 78:22 weight ratio and apply coat 1 as per manufacturer’s general method statement ‘MS - AD - Sikagard®-1816-01/2024’ and PDS '020303000000002044 Version 01.01', dated April 2024. Cure coat 1 for 9 hours@25°C. Mix parts A & B in a 78:22 weight ratio and apply coat 2 as per manufacturer’s general method statement ‘MS - AD - Sikagard®-1816-01/2024’ and PDS '020303000000002044 Version 01.01', dated April 2024. Cure coat 2 for 14 days@25°C. For use with water up to 23°C. This material is only approved for the mixing & curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Hydroplate 1914'. Site applied, two-component, white coloured (once mixed and applied) Epoxy-polyamine coating. Mix parts A & B in a 3:1 weight ratio and apply as per manufacturer's Product Data Sheet 'B034', dated 'September 2024'. Cure coat 1 for 48 hours at 15°C. Cure coat 2 for 21 days at 15°C. For use with water up to 50°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
FORTRON® natural (appears cream) or black coloured, injection moulded PPS materials. For use with water up to 85°C. Grades manufactured in Celanese Florence, USA: FORTRON® 1140L4 SF3001 NATURAL FORTRON® 1140L4 SD3002 BLACK DW (formerly known as FORTRON® 1140L4 BLACK SD3002). FORTRON® 1140L6 SD3002 BLACK DW (formerly known as FORTRON® 1140L6 BLACK SD3002). FORTRON® 1140L6 SF3001 NATURAL FORTRON® 4184L6 SF3001 NATURAL FORTRON® 4184L6 SD3002 BLACK DW (formerly known as FORTRON® 4184L6 BLACK SD3002). Grades manufactured in Celanese Nanjing: FORTRON® 1140L4 SF3001 NATURAL DW (formerly known as FORTRON® 1140 L4 SF3001 natur CN). FORTRON® 1140L4 SD3002 BLACK DW (formerly known as FORTRON® 1140 L4 SD 3002 black).
'Amodel DW-1140 BK 938 & Amodel DW-1150 BK 938'. Black coloured, injection moulded PPA materials. For use with water up to 85°C.
'EP701443C 'O' rings'. Black coloured, compression moulded EPDM 'O' rings. Shore hardness 70. Tested in-radius size 1.75mm. For use with water up to 85°C.
Range of single hole, single outlet electronically controlled tap assemblies (chromium plated brass), incorporating a solenoid valve controlling the flow which is actuated via infrared sensor. The spouts incorporate plastic aerators. Maximum working pressure 8.0 Bar. Maximum operating temperature 65.0°C
Range of deck mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). Flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. The main body incorporates a plastic flow regulator and stainless steel strainer prior to the solenoid. The inlets to the main body of the GS10, CM10 & GH10 model variants incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. These models also have a manual temperature control operated by a single lever on the side of the body. The inlet hoses incorporate a TPE gasket. The models are supplied with or without a pop-up waste. The GS20 & GM20 model variants are single feed. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of deck mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). Flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. The inlets to the main body of the M10, GC10, MX10, A10 & L10 model variants incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection, these models also have a manual temperature control operated by a single lever on the side of the body. The inlet hoses incorporate a stainless steel strainer (M10, GC10, MX10, A10 & L10 model variants) or combined TPE washer and stainless strainer (M20, GC20, A20 & L20 model variants). The models are supplied with or without a pop-up waste. The M20, GC20 A20 & L20 model variants are single feed. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Side entry BS1212-4 (2016) compact type float operated valves for use with WC flushing cisterns. The inlet incorporates a strainer. Maximum working pressure 10.0 bar. Cold water use only.
Range of side and bottom entry BS1212-3 inlet valves, with plastic bodies and brass shanks. Maximum working pressure: 3.0 Bar low pressure and 14.0 bar high pressure Maximum operating temperature: Cold water use only.
Range of side and bottom entry BS1212-3 inlet valves, with plastic bodies and brass shanks. Maximum working pressure: 3.0 Bar low pressure and 14.0 bar high pressure Maximum operating temperature: Cold water use only.
Range of side and bottom entry BS1212-3 inlet valves, with plastic bodies and brass shanks. Maximum working pressure: 3.0 Bar low pressure and 14.0 bar high pressure Maximum operating temperature: Cold water use only.
Bottom entry A1370A and side entry A1423B BS1212-4 (2016) compact type float operated valves for WC flushing cisterns. The inlet incorporates a strainer. A1270A - plastic or brass connector. A1423B - plastic connector only. Maximum working pressure 10.0 bar. Cold water use only.
BS EN 14055 (2018) concealed WC cistern incorporating a side or bottom entry compact type float operated inlet valve discharging via a type AG airgap and a dual or single flush pneumatic or dual flush cable operated drop valve capable of full flush volumes of up to 6 litres with a reduced flush of up to 4 litres. The cistern is operated by manual push button/push plate. The side entry inlet valve is mounted internally and is supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.
Range of ceramic cartridge headworks with brass bodies and EPDM gaskets and O-rings. For insertion into specifically dimensioned bores. Maximum working pressure; 5 Bar Maximum operating temperature 60°C
Page 49 of 61
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.