Range of electromagnetic water meters with stainless steel bodies and natural rubber liners. Maximum working pressure 16.0 bar. Maximum operating temperature 60°C.
Range of ultrasonic water meters with brass/plastic bodies. The inlets incorporate plastic strainers and brass spherical ball valves. Maximum working pressure 16.0 bar. Maximum operating temperature 50⁰C.
Range of ultrasonic water meters with brass bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85⁰C.
Impeller with plastic body for insertion into specifically dimensioned bores. Maximum operating temperature 65°C.
Water shock absorber incorporating a stainless-steel body and EPDM membrane. Maximum working pressure 15.0 bar. Maximum operating temperature 85°C.
Range of heat interface units providing heating and instantaneous hot water. The central heating and hot water are generated via plate heat exchangers. The central heating circuit contains a pressure relief valve (3.0 bar) and an expansion vessel. The cold inlet supply to the plate heat exchanger incorporates an in line single check valve assembly, (suitable for backflow protection against Fluid Category 2). Max Temperature & Pressure for models A/7892284 & B/7892283: Primary Circuit: 6.0 bar at 90°C DHW Circuit: 10.0 bar at 55°C Secondary Circuit 6.0 bar at 90°C Max Temperature & Pressure for all other models: Primary Circuit: 16.0 bar at 90*C, DHW Circuit: 10.0 bar at 65*C, Secondary Circuit 3 bar at 85*C.
Mini expansion vessels/shock arrestor with a stainless-steel body and butyl rubber diaphragm. Maximum working pressure 10.0 bar. Cold water use only.
Turbine flow sensor with plastic bodies and plastic turbines. Open outlet use only. Maximum operating temperature 23.0°C.
Range of shock arrestors with a stainless-steel body and EPDM liner. The compression connection of the X2041.015 model is for use with copper pipe (manufactured to EN1057). Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Shock arrestors with a copper body, plastic shuttle and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of multistage centrifugal pumps with stainless steel impellers, intermediate chambers, shaft and outer sleeve. The DPV(M/S) models and DPV(S) models can also incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressures: Existing models: DPV models 10.0 bar, DPVM models with an oval flange or VME models with integral check valve 16.0 bar, All other DPVM models 25.0 bar. DPV(S) models with an oval flange or DPV(S)(E) models with integral check valve 16.0 bar, All other DPV(S) models and DPH(S)I models 25.0 bar. Maximum operating temperatures: DPHM, DPVE and DPVME models with integral check valve 60°C, all other model variants 100°C.
Range of horizontal multistage pumps with stainless steel bodies, diffuser and impellers and EPDM ‘O’-rings. The products incorporate a graphite-SiC-EPDM shaft seal. The products incorporate a drain plug. Maximum working pressure 8.5 bar. Maximum operating temperature 35°C.
A range of variable speed booster pumps with stainless steel bodies and impeller. Maximum working pressure: 8 bar. Maximum operating temperature: 35°C.
Range of interlocked EPDM lined shower hoses assemblies with EPDM gaskets. Maximum operating temperature: 85°C Open outlet use only.
Range of shower handsets and headsets with chromium plated plastic bodies. Models P60901 and P61400 have check valves fitted at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. Maximum working pressure: Open outlet. Maximum operating temperature: 60.0°C.
Range of fixed shower arms, (brass bodies - various finishes) with EPDM O-Rings. Maximum operating temperature: 85°C, open outlet use only.

Range of shower arms with brass bodies. Models 91xx7034 & 91xx9323 incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 80.0°C (models 86xxxxxx) or 60.0°C (models 91xxxxxx)
Range of wall mounted shower outlets (chromium plated brass). Maximum operating pressure 10.0 bar. Maximum operating temperature 65°C.
Range of shower outlets and accessories with brass and plastic bodies (various finishes). Overhead shower inlets incorporate stainless steel strainers. Maximum working pressure 5.0 bar. Maximum operating temperature 60⁰C.
Range of (chrome plated) plastic shower handsets with flexible shower hose and stainless-steel braided connection hose. The inlet incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C. Open outlet use only.
Page 438 of 522
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.