Range of copper brazed, stainless steel heat exchangers in various sizes (4-300 plates, see model). Models size X8T-SC-S Maximum working pressure primary circuit: 32.0 bar Maximum working pressure secondary circuit: 26.0 bar Maximum operating temperature: 99°C Models size 10T-SC-M Maximum working pressure primary circuit: 41.0 bar Maximum working pressure secondary circuit: 36.0 bar Maximum operating temperature: 99°C Models size 15T-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45 bar Maximum operating temperature: 99°C Models size 16DW-SC-S Maximum working pressure primary circuit: 16.0 bar Maximum working pressure secondary circuit: 16.0 bar Maximum operating temperature: 99°C Models size 16DW-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45.0 bar Maximum operating temperature: 99°C Models size 220-SC-S Maximum working pressure primary circuit: 25.0 bar Maximum working pressure secondary circuit: 25.0 bars Maximum operating temperature: 99°C Models size 320HT-SC-S Maximum working pressure primary circuit: 33.0 bar Maximum working pressure secondary circuit: 29.0 bar Maximum operating temperature: 99°C Models size 320LT-SC-S Maximum working pressure primary circuit: 33.0 bars Maximum working pressure secondary circuit: 29.0 bars Maximum operating temperature: 99°C
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. Incorporating a pressure relief valve and expansion vessel. Primary circuit has a maximum working pressure of 3.5 bar and operating temperature of 85°C. Secondary circuit has a maximum working pressure of 10.0 bar and operating temperature of 60°C.
Air break to drain, incorporating brass bodies with a grey epoxy powder coating. Maximum operating temperature 60°C.
Wall mounted chrome plated brass elbow fitting. Maximum working pressure 5.0 bar. Maximum operating temperature 70°C.
Hygienic flush box providing a timed flush facility. The supply is via a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection, flow sensor, spherical ball valve and strainer. The products incorporate a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The units have multiple interface user functions for timed flush, wireless technology and data storage. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Maincor Manifold having a brushed chrome plated body with 2 ,3 or 4 ports each with an isolation valve with red or blue indicators for hot and cold feeds. Supplied with a blanking plug and nut. Maximum working pressure 6.0 bar. Maximum operating temperature 75°C.
Range of flow measurement devices (DZR brass) bodies incorporating two test ports. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.
Range of interlocked EPDM lined shower hoses assemblies with EPDM gaskets. Maximum operating temperature is 85°C. bar.
Range of shower handsets incorporating ABS bodies (chrome plated), EPDM seals and ‘O’-rings. Maximum operating temperature 65°C.
Wall mounted vandal resistant shower head with (chrome plated brass finish). The inlet incorporates an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The outlet incorporates a plastic aerator. Open outlet use only. Maximum operating temperature 60°C.
A range of shower handsets with chromium plated plastic bodies and a plastic strainer and flow regulator in the inlet. Models may incorporate dark grey alternative shower plate. Maximum operating temperature 85°C.
Overhead, ceiling mounted shower outlet with chromium plated brass body (various finishes). Maximum operating temperature 60°C.
Shower handset incorporating a plastic body (chrome plated), brass wall connector (chrome plated) and shower hose. The inlet to the shower and wall connector incorporates approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of over head shower outlets incorporating brass bodies and an adjustable ball joint. The inlet incorporates a combined NBR washer and stainless-steel filter. Maximum operating temperature 60°C.
Range of wall mounted shower kit with brass bodies (various finishes) consisting of a shower rail with an overhead shower rose, incorporating a manual diverter to shower handset. Shower handset incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models AOOSCPUK and AOOSBKUK consist of just a shower handset. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of shower outlets with brass bodies (various finishes) and NBR ‘O’ rings. The inlets incorporate a flow regulator. Maximum operating temperature 60°C. Open outlet use only.
Range of wall mounted shower outlets (chromium plated brass). Models ARMW02 and ARMW05 are supplied with metal backnuts. Maximum operating pressure 10.0 bar. Maximum operating temperature 65°C.
Range of in-line `Y`-patterned strainers with either brass or DZR brass bodies (see model) incorporating a stainless steel mesh strainer and a PTFE washer. Maximum working pressure 25.0 Bar. Maximum operating temperature 99.0°C
Range of Y-patterned strainers incorporating ductile iron, blue epoxy coated bodies and stainless steel screen. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of Y-patterned strainers incorporating ductile iron, blue epoxy coated bodies and stainless steel screen. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Page 5 of 427
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.