Directory Search Results

Print List

#2012353

Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.

Section:
1350 Heat Exchangers
Size:
¾” BSP (M)
Marking:
Inta logo, address, serial number, technical & pressure information on label inside case.
Installation Requirements:
R001
Expiry date:
31/12/2025
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
HIPER2TPSZ80 HIPER2SPSW80 HIPER2SPSW80IS HIPER2SPSW80ZE
Product Images

Approval Holder:
Intatec Limited
Company Name
Intatec Limited
Address
Airfield Industrial Estate Hixon Staffordshire
Postcode
ST18 0PF
Country
United Kingdom
Phone
01889272180
General Email
ryan.tilsley@intatec.co.uk

View All Listings by this Company

Print This Approval


#2010078

Range of RINNAI continuous flow water heaters with stainless steel plate heat exchangers providing heating and instantaneous hot water .The hot water is generated via a plate heat exchanger. Also supplied is a drain valve and a flow sensing device. Maximum working pressure - 10 bar Maximum working pressure - 85˚C

Section:
1350 Heat Exchangers
Size:
¾” Male inlet and outlet
Marking:
RINNAI on body and data badge including date of manufacture (YY/MM)
Installation Requirements:
R001
Expiry date:
31/10/2025
Model:
REU-N3237FFC-E – N1600i (57.9kW / 29Kg) REU-N3237WC-E – N1600e (57.9kW / 29Kg) REU-N2635FFC-E – N1300i (47kW / 28Kg) REU-N2635WC-E – N1300e (47kW / 28Kg)
Product Images

Approval Holder:
Rinnai UK Ltd
Company Name
Rinnai UK Ltd
Address
9 Christleton Court Manor Park Runcom
Postcode
WA7 18T
Phone
01928 531 870
General Email
info@rinnaiuk.com

View All Listings by this Company
Manufacturer:
Rinnai UK Ltd
Company Name
Rinnai UK Ltd
Address
9 Christleton Court Manor Park Runcom
Postcode
WA7 18T
Phone
01928 531 870
General Email
info@rinnaiuk.com

View All Listings by this Company

Print This Approval


#2012365

Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.

Section:
1350 Heat Exchangers
Size:
¾” BSP (M)
Marking:
BAXI ON FRONT OF CASING. BAXI, address, serial number, technical & pressure information on label inside case.
Installation Requirements:
R001
Expiry date:
31/12/2025
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
BAXI ASSURE HIMAX TWIN ID 90/30 ELECTRONICALLY CONTROLLED HEAT INTERFACE UNITS

Approval Holder:
Baxi Heating UK Limited
Company Name
Baxi Heating UK Limited
Address
Brooks House, Coventry Road, Warwick
Postcode
CV34 3LL

View All Listings by this Company

Print This Approval


#2012366

Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.

Section:
1350 Heat Exchangers
Size:
¾” BSP (M)
Marking:
RBM, address, serial number, technical & pressure information on label inside case.
Installation Requirements:
R001
Expiry date:
31/12/2025
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
37370000 ELECTRONICALLY CONTROLLED HEAT INTERFACE UNITS
Product Images

Approval Holder:
RBM S.p.a.
Company Name
RBM S.p.a.
Address
Componenti Per Impianti Idrotermici Via S. Giuseppe, 1 25075 Nave (Brescia)
Country
Italy

View All Listings by this Company

Print This Approval


#2105309

Copper heat transformer. Maximum working pressure 11.0 bar. Maximum operating temperature 95°C.

Section:
1350 Heat Exchangers
Size:
76mm copper tube
Marking:
Company name and address, model, operating parameters, size & date of manufacture (MM/YYYY) on body.
Installation Requirements:
R001
Expiry date:
31/05/2026
Model:
Heat Transformer 60
Product Images

Approval Holder:
Copper Industries Ltd
Company Name
Copper Industries Ltd
Address
Toome Business Park 21 Hillhead Road Toome Co Antrim
Postcode
BT41 3SF
Country
United Kingdom
Phone
02879 659736
General Email
mail@copperindustries.co.uk

View All Listings by this Company
Manufacturer:
Copper Industries Ltd
Company Name
Copper Industries Ltd
Address
Toome Business Park 21 Hillhead Road Toome Co Antrim
Postcode
BT41 3SF
Country
United Kingdom
Phone
02879 659736
General Email
mail@copperindustries.co.uk

View All Listings by this Company

Print This Approval


#2105044

Range of domestic hot water units incorporating instantaneous or semi-instantaneous plate heat exchanger assemblies. The product incorporates a motorised control valve, managed primary and secondary pumps (see model), and a drain valve on both circuits. Maximum working pressures: 10.0 bar primary, 9.5 bar secondary. Maximum operating temperatures: 110°C primary, 85°C secondary.

Section:
1350 Heat Exchangers
Size:
1 ¼” BSP (F) on both primary and secondary circuits.
Marking:
Cetetherm SAS, AQUAFIRST, Max working pressure/temperature for primary and secondary circuits, serial number, article number and year of manufacture (YYYY) on adhesive label on heat exchanger frame.
Installation Requirements:
R001 R140 R360
Expiry date:
31/05/2026
Model:
AQUAFIRST 2000/4000/6100/8000 series: Flxxnnyy FI = Aquafirst range xx = 20: 2000 M3 Plates serie (differentiation on primary side). 40: 4000 M3 Plates serie (differentiation on primary side). 61: 6100 M6 Plates serie (differentiation on primary side and secondary pump). 80: 8000 M6 Plates serie (differentiation on primary side and secondary pump). nn = 07 up to 55 for the number of gasketed plates. yy = IS: Instantaneous (no pump on DHW) with single primary pump ID: Instantaneous (no pump on DHW) with twin head primary pump SS: Semi-instantaneous with one primary pump and one DHW pump DS: Semi-instantaneous with twin head primary pump and one DHW pump DD: Semi-instantaneous with twin head primary pump and two DHW pump Article Number: FI2007IS. FI2007ID. FI2007SS. FI2007DS. FI2007DD. FI2017IS. FI2017ID. FI2017SS. FI2017DS. FI2017DD. FI4027IS. FI4027ID. FI4027SS. FI4027IS. FI4027DD. FI4045IS. FI4045ID. FI4045SS. FI4045DS. FI4045DD. FI6113IS. FI6113ID. FI6113SS. FI6113DS. FI6113DD. FI6123IS. FI6123ID. FI6123SS. FI6123DS. FI6123DD. FI8031IS. FI8031ID. FI8031SS. FI8031DS. FI8031DD. FI8055IS FI8055ID FI8055SS FI8055DS FI8055DD.
Product Images

Approval Holder:
CETETHERM SAS
Company Name
CETETHERM SAS
Address
Route du stade ZI du moulin Pontcharra sur Turdine
Postcode
69490
Country
France
General Email
jeanmichel.montoni@cetetherm.com

View All Listings by this Company
Manufacturer:
CETETHERM SAS
Company Name
CETETHERM SAS
Address
Route du stade ZI du moulin Pontcharra sur Turdine
Postcode
69490
Country
France
General Email
jeanmichel.montoni@cetetherm.com

View All Listings by this Company

Print This Approval


#2007344

Range of ‘HYCO’ electric instantaneous water heaters with plastic bodies, NBR and silicone ‘O’-rings. The inlet of model IN96T incorporates a plastic strainer. Maximum working pressure 7.5 bar. Maximum operating temperature 60°C.

Section:
1360 Heaters
Section Subtitle:
Electric instantaneous, mains fed, closed outlet. Heat retained in instantaneous water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2007344
Size:
½” BSP male inlet/outlet
Marking:
Hyco, serial number, model, manufacturer, address, contact No, product code and other technical information side of unit.
Installation Requirements:
R001
Expiry date:
31/07/2025
Model:
IN44T, IN60T, IN96T, IN44 & IN60.
Product Images

Approval Holder:
Hyco Manufacturing Ltd
Company Name
Hyco Manufacturing Ltd
Address
California Drive, Castleford, West Yorkshire
Postcode
WF10 5QH

View All Listings by this Company
Manufacturer:
Hyco Manufacturing Ltd
Company Name
Hyco Manufacturing Ltd
Address
California Drive, Castleford, West Yorkshire
Postcode
WF10 5QH

View All Listings by this Company

Print This Approval


#2007062

‘Hydraulic Block 2’ range of integrated water circuits for use with combination boilers comprising of a plastic body, stainless steel thermistors and a plate heat exchanger. The primary circuit incorporates a pump assembly. Maximum working pressures: Primary Circuit 2.5 bar. Secondary Circuit 10.0 bar. Maximum operating temperatures: Primary circuit 85˚C. Secondary circuit 65°C. Cold supply only.

Section:
1478 Heater
Section Subtitle:
Combination boilers - accessories and components.
WRAS Approval Number:
2007062
Size:
Primary Circuit: ¾” BSP (M) inlet and outlet. Secondary Circuit: ½” BSP (M) inlet and outlet.
Marking:
Navien printed onto hydraulic block circulator pump. Model and size on adhesive label on plate heat exchanger.
Installation Requirements:
R001
Expiry date:
31/07/2025
Model:
30015738 (24kW). 30015737 (28kW). 30024563 (34kW). 30024564 (40kW).
Product Images

Approval Holder:
KD Navien (Korea)
Company Name
KD Navien (Korea)
Address
13-6 Koami Bidg 13-6 Yeouido-Dong Yeongdeungpo -Gu
Country
Seoul

View All Listings by this Company

Print This Approval


#2011351

Hydroblock unit consisting of a stainless steel heat exchanger, a pressure relief valve pre-set at 3.0 bar, diverter valve and return valve. Maximum working pressure 2.5 bar. Maximum operating temperature 90°C

Section:
1478 Heater
Section Subtitle:
Combination boilers - accessories and components.
WRAS Approval Number:
2011351
Size:
Primary side – ¾” BSP (M) x 18.8mm manifold. Secondary side – ½” BSP (M) x ½” BSP (M)
Marking:
Hydro Zero logo & model on body
Installation Requirements:
R001
Expiry date:
30/11/2025
Model:
Hydroblock HB-112
Product Images

Approval Holder:
Hydro Zero Ltd.
Company Name
Hydro Zero Ltd.
Postcode
LS28 9LE

View All Listings by this Company

Print This Approval


#2007014

Digital water meter with brass body incorporating a plastic strainer on the inlet and a non-return valve (not suitable for backflow protection) on the outlet. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.

Section:
1505 Water Meters
Size:
1 ½” BSP (M) inlet/oulet.
Marking:
LUNA on cap. Flow arrow on body. LUNA, model, year of manufacture (YYYY) and tech info on meter face
Installation Requirements:
R001
Expiry date:
31/07/2025
Model:
WORLD WD-DDJ-32-B multijet dry type digital water
Product Images

Approval Holder:
LUNA Elektrik Elektronik Sanayi ve Ticaret AS
Company Name
LUNA Elektrik Elektronik Sanayi ve Ticaret AS

View All Listings by this Company
Manufacturer:
LUNA Elektrik Elektronik Sanayi ve Ticaret AS
Company Name
LUNA Elektrik Elektronik Sanayi ve Ticaret AS

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 5 of 96

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.