Shower handset with brass body (various finishes). Supplied with a shower hose and wall elbow. Handset inlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure: Open Outlet. Maximum operating pressure: 85oC.
Range of brass ceiling mounted shower tubes, in a variety of finishes. For use with copper pipe to EN 1057. Maximum operating temperature 80.0°C
Range of shower handsets with (plastic bodies - various finishes Maximum operating temperature 60°C. Open outlet use only.
Range of shower sets incorporating a shower hose, shower handset and wall mount. The shower outlet on the wall mount incorporates an approved single check valve (however the complete assembly has not been tested to verify it provides backflow protection). Maximum operating temperature 60°C. Open outlet use only.
Range of Y pattern strainers having either brass (899ST range) or bronze (900 range) bodies and PTFE seat washers. Maximum working pressure 20.0 Bar see model Maximum working pressure 32.0 Bar see model Maximum operating temperature 100.0°C.
A range of ‘Y’-patterned strainers with bronze bodies incorporating a stainless-steel mesh strainer and PTFE washers. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of In-line Y patterned strainer with cast iron bodies (blue epoxy coated) and stainless-steel screens. Maximum working pressure 16.0 Bar. Maximum operating temperature 85.0°C.
Range of bib taps (nickel plated brass) or (DZR brass) bodies – see models, incorporating a spherical valve to control the flow. The products incorporate single lever operating members. Some models are supplied with lock shields (see models). The spout outlet incorporates a hose union spigot connection with a plastic flow straightener. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C.
Range of wall mounted hose union bib taps incorporating a rising spindle headwork with a T - handle operating member and brass body. The spout outlets incorporate a hose union connector. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of wall mounted hose union bib taps incorporating a rising spindle headwork with a T - handle operating member and a brass body. The spout outlets incorporate a hose union connector. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of shower hoses, multi-layered hose (silver external appearance) with PVC inner liner, brass end connections. Open outlet use only. Maximum operating temperature 60°C.
Stainless steel braided or nylon braided PEX lined flexible hose assemblies with various end connections. Maximum working pressure 10.0 Bar Maximum operating temperature 85 °C.
Range of stainless steel braided, PEX lined flexible hose assemblies with a variety of end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of stainless-steel braided EPDM lined flexible hose assemblies with EPDM seals, available with a variety of end connections, some of which include isolation valves (see model). Maximum working pressure 10 Bar. Maximum operating temperature 85°C
Range of stainless steel braided, TPSiv lined flexible hose assemblies. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of Nickel plated brass manifolds with two, three or four outlets, for use with copper pipe (manufactured to EN1057). The products incorporate a screw down isolation valve at each port. Maximum working pressure 6.0 bar. Maximum operating temperature 85°C.
S851 series of air venting valves, with blue epoxy coated ductile iron bodies. Maximum working pressure 16.0 Bar Maximum operating temperature 50.0°C
Range of wall mounted, concealed, manually operated blending valves (brass bodies) incorporating a ceramic cartridge headwork with a single lever operating member. Maximum working pressure: 10.0 bar. Maximum operating pressure: 60oC.
Range of wall mounted, manually operated blending valves (brass bodies, chromium plated) incorporating a ceramic cartridge headwork with a single lever operating member. Outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure: 10.0 bar. Maximum operating pressure: 60oC.
Wall mounted, concealed, manually operated blending valve (brass body), incorporating a ceramic cartridge headwork with a single lever operating member. Maximum working pressure: 5.0 bar. Maximum operating pressure: 60oC.
Page 393 of 590
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.