Multistage, vertical booster pumps with a brass body and stainless steel pump housing, stainless steel impellers and EPDM ‘O’-rings. The 41782 (MV90 4M VSD) model includes a pressure transducer. Maximum working pressure 6.0 bar. Cold water use only.
Range of multistage centrifugal pumps with stainless steel bodies and impellers, and EPDM ‘O’-rings. Maximum operating pressure 11.0 bar. Maximum working temperature 90°C.
Range of horizontal self-priming multistage pumps with stainless steel bodies, stainless steel impellers, shaft and outer sleeve. Maximum working pressure 10.0 Bar Maximum operating temperatures: EH Three phase models 85°C, EH Single phase models 55.0°C and EHsp models 35°C.
Range of self-priming pumps with stainless steel bodies and impellers, and EPDM ‘O’-rings. Maximum working pressure 7.0 bar. Cold water use only. From November 2021 maximum operating temperature 60°C
Range of single stage end suction pumps with stainless steel or cast iron pump housings, EPDM ‘O’-rings and wear rings available in low-lead bronze/brass or stainless steel. Cast iron models are coated in black cathodic paint (textured finish) or black epoxy (smooth finish). The pumps are available with carbon graphite/silicon carbide mechanical shaft seal. Impellors are available in cast iron with black cathodic paint, low-lead bronze or stainless steel. The pumps are available with fixed flange, as well as loose flange (model dependent). Maximum working pressure 10.0 or 16.0 bar depending on model. Maximum operating temperatures: Stainless steel and cast iron with (smooth) epoxy coating pumps 85°C. Cast iron pumps with (textured) cathodic paint coating are cold water use only.
Range of inline circulating pumps with bronze bodies, plastic impeller and EPDM rubber seals. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Range of booster pumps with stainless steel bodies and impellers, EPDM ‘O’-rings and a ceramic/graphite/EPDM shaft seal. Maximum working pressure 6.0 bar. Maximum operating temperature 40°C.
Range of booster pumps with stainless steel bodies and impellers, EPDM ‘O’-rings and a ceramic/graphite/EPDM shaft seal. Maximum working pressure 7.0 bar. Cold water use only. From November 2021 maximum operating temperature 60°C
Range of shower handsets incorporating chromium plated plastic or chromium plated brass bodies (see model). Inlets incorporate a plastic flow regulator. Maximum operating temperature 60°C.
Range of overhead shower outlets incorporating brass bodies (chrome plated) and EPDM gaskets. Inlets have stainless filters incorporated within a ball joint. Maximum operating temperature 85°C
Range of overhead shower outlets (chrome plated plastic bodies). Inlets incorporate a strainer. Maximum operating temperature 85°C
Range of shower outlets with brass bodies (various finishes) incorporating NBR ‘O’-rings (280R/W model) or EPDM ‘O’-rings (286P/W model). The inlet of the 286P/W model incorporates a plastic flow regulator. Maximum operating temperature 60°C.
Range of wall mounted shower outlets (brass bodies), shower hoses and handsets available in various finishes (see model). The shower outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Shower head (various finishes) with a built in flow restrictor. Maximum operating temperature 60°C.
Range of shower handsets with chrome plated bodies and built in flow restrictors. Maximum operating temperature 60°C.
Range of rim/deck mounted shower handsets with brass bodies (various finishes). The inlet (except for the D5A A02 60A/W model) incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet of the D5A A02 60A/W model incorporates a plastic flow restrictor. The products are supplied with a shower hose and a stainless steel braided EDPM lined flexible hose assembly (for connection prior to the shower hose). Maximum working temperature 60°C.
Range of shower rose outlets (plastic body with various finishes). The inlet incorporates a stainless-steel strainer. Maximum operating temperature 60°C. Open outlet use only.
Range of shower outlets with brass bodies (various finishes) incorporating NBR ‘O’-rings. Maximum operating temperature 60°C.
Range of ceiling tubes (brass bodies - various finishes) intended for use with shower heads. Maximum operating temperature 85°C.
Range of inline ‘Y’- patterned strainers with brass bodies & stainless steel filters. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Page 38 of 427
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.