Concealed, wall mounted, manual shower blending valve incorporating a brass body (various finishes) with ceramic cartridge headwork with a single lever operating member. Maximum working pressure: 10.0 Bar. Maximum operating temperature: 60 °C.
Range of wall mounted, manually operated, shower valves (chromium plated brass), incorporating a ceramic cartridge headwork controlling both flow and temperature using a single lever operating member. The products (except for S suffix models) are supplied with ¾” x ½” offset union adaptors which incorporate a servicing valve. The inlets of models containing EP include plastic filters and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. All other models incorporate plastic flow regulators on each inlet and an approved single check valve cartridge on the outlet, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted thermostatic blending shower valves (brass bodies – various finishes) incorporating quarter turn ceramic disc two-way diverter headwork controlling the flow with dome or square type operating members. Temperature is controlled independently via a thermostatic cartridge incorporating a manual override button with dome or square type operating members. The inlets incorporate a stainless-steel strainer and approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure; 5 Bar Maximum operating temperature 60°C
Range of wall mounted concealed thermostatic blending valves with brass bodies (various finishes), incorporating single sequential headworks with single lever operating members. The inlet couplings incorporate plastic flow regulators & metal strainers. The outlets incorporate approved check valve cartridges, however, the complete products have not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 8.0 Bar Maximum operating temperature 60.0°C
Range of wall mounted concealed thermostatic blending valves, (brass bodies – various finishes). Model (TVT126001000xx) incorporates a quarter turn ceramic disc headwork. Model (TVS126003000xx) incorporates a two-way ceramic disc diverter headwork. Temperature is controlled independently via a thermostatic mixing cartridge that incorporates a manual override button. Both models incorporate approved check valve cartridges; however, the complete products have not been fully tested to demonstrate they provide backflow protection. Maximum working pressure 5.0 Bar or 10.0 Bar (see models). Maximum operating temperature 60°C.
Range of thermostatic bar shower mixers, incorporating a quarter turn ceramic disc headwork controlling the flow with a dome type of operating member. The temperature is controlled independently via a thermostatic mixing cartridge incorporating a manual override button. Inlets incorporate single check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models ZI SHXSMCT C & ZI SHXSMCTFF C are supplied with a shower hose, handset and a riser rail. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of thermostatic bar shower mixers, (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with a dome type operating member. Temperature is controlled independently via a thermostatic mixing cartridge with a dome type operating member that incorporates a manual override button. The Inlets incorporate stainless steel strainer washers and approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Model (FZ SHXVOCTFF C) is not supplied with a shower hose, shower handset and a riser rail. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of wall mounted, concealed thermostatic shower valves (brass bodies – various finishes) incorporating a 2 way or 3 way diverter controlling the flow to multiple shower outlets using a dome type operating member. Temperature is controlled independently via a thermostatic cartridge incorporating a manual override button with a dome type operating member. The inlets incorporate approved single check valve cartridges however, the complete assembly has not been fully tested to demonstrate that it provides backflow protection. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of T-type blending valve with brass bodies and thermostatic cartridges. Compression models are for use with copper pipe manufactured to EN1057. Maximum working pressure 25.0 Bar. Maximum operating temperature 75°C.
Range of lugged or wafer butterfly valves with either lever or hand wheel operation and a blue epoxy coated ductile iron body. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of butterfly valves with blue epoxy coated ductile iron bodies and discs, and EPDM seals with a wheel type operating member. Maximum working pressure 16.0 Bar Maximum operating temperature 85.0°C
Non-metallic materials and components comply with BS6920 at 85°C
Range of lug, wafer or flanged (see models) butterfly valves with blue epoxy coated ductile iron bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of butterfly valves with an epoxy coated ductile iron body, stainless steel disc and single lever or handwheel operating members. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of concealed, 2-way manual diverter valves incorporating a brass body. To be installed with 59556 000070 IXMO installation unit. Maximum working pressure 10.0 Bar. Maximum operating temperature 70°C.
Range of below ground (screw down type) fire hydrants with coated cast iron bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of in-line, manually adjustable pressure reducing valves with nickel plated DZR brass body. Maximum inlet supply pressure 25 bar. Maximum operating temperature 80°C
Range of pressure reducing valves with DZR brass or bronze bodies and manually adjustable outlet pressure range between 2.5bar to 6.0bar Maximum working pressure: 25.0 bar Maximum operating temperature 80°C.
Range of pressure reducing valves with DZR brass or bronze bodies and manually adjustable outlet pressure range between 2.5bar to 6.0bar. Maximum working pressure: 25.0 bar. Maximum operating temperature 80°C.
Range of pressure reducing valves with DZR brass or bronze bodies and manually adjustable outlet pressure range between 2.5bar to 6.0bar. Maximum working pressure: 25.0 bar. Maximum operating temperature 80°C.
Range of pressure reducing valves with DZR brass or bronze bodies and manually adjustable outlet pressure range between 2.5bar to 6.0bar. Maximum working pressure: 25.0 bar. Maximum operating temperature 80°C.
Page 355 of 427
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.