WC dual flush drop valve with ABS body and silicone seals. The valve is operated via a two push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Range of WC dual flush drop valves operated via a two-push button assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Range of wall mounted, electronic tap assemblies which are set within a mirrored cabinet unit. The flow is controlled by a solenoid valve assembly and is activated via infra-red non touch operation. The units also incorporate a soap dispenser and hand dryer or paper towel dispenser. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Indirect heat interface unit with copper brazed, stainless-steel heat exchangers, providing heating and instantaneous hot water. The product incorporates an expansion vessel on the cold-water supply to the plate heat exchanger and a safety relief valve on the heating circuit set @ 2.5 bar. The DHW and heating circuits are both fitted with drain valves incorporating cover caps. Maximum working pressure 16 Bar (Primary), 10 Bar (DHW) & 3 Bar (Heating) Maximum operating temperature 95°C
Ultrims Ultrasonic range of in-line water meters with brass or plastic (-01 suffix models) bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meters with brass bodies and plastic turbines. The inlet incorporates a plastic filter. Maximum working pressure 16.0 bar. Maximum operating temperatures Sizes DN15-25 models: 50°C, sizes DN32-40 models: 85°C.
Range of in-line water meters with brass bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of water meters with brass bodies, plastic turbines and plastic strainers on inlets. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C
Range of submersible pressure sensors and hydrostatic transmitters (supplied in lengths up to 1000m). Cold water use only.
Hydraulic circuit used to control the water path within the heating and sanitary boiler, with plastic body incorporating filter, flow regulator, plate heat exchanger and EPDM O-rings. Maximum working pressure 7.0 bar. Maximum operating temperature 85°C.
Concealed, floor mounted basic set with DZR brass body. For use with floor standing combination tap assemblies. Maximum operating pressure 10 bar. Maximum operating temperature 70°C
Peripheral pump for mains water applications with a brass body and impeller, . The pushfit connections on the hoses are for use with copper pipe (manufactured to EN 1057). Maximum working pressure 6.0 bar. Cold water use only.
‘Monsoon Standard’ range of single and twin ended shower booster pumps with brass bodies, brass impellers, EPDM seals and NBR ‘O’-rings. The inlet(s) of the pump body incorporate(s) a plastic strainer. Models with push fit connections include an integral isolation valve. Pushfit connections are for use with copper pipe (manufactured to EN 1057). Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
Range of horizontal or vertical multi-stage pumps with a stainless-steel body (HM models) or cast iron body with blue coloured cationic resin coating (VM models), incorporating either plastic or stainless-steel impellers (see model), stainless steel sleeve, EPDM gaskets and seals. Maximum working pressure 10.0 bar / 16.0 bar (see models). Cold water use only.
Range of single or twin shower pumps with brass bodies, brass impeller supplied with flexible connection hoses that incorporate servicing valves. Maximum Working pressure 6 Bar Maximum operating temperature 65°C
‘Hydro MPC’ range of booster sets incorporating vertical multistage centrifugal pumps, butterfly valves, non-return valves (not suitable for backflow protection), pressure transmitters, pressure gauges, lever operated spherical valves, stainless steel blanking flanges and fibre/NBR gaskets. Maximum working pressure 16.0 bar. Cold water use only. ‘Hydro MPC’ range of booster sets incorporating vertical multistage centrifugal pumps, butterfly valves, non-return valves (not suitable for backflow protection), pressure transmitters, pressure gauges, lever operated spherical valves, stainless steel blanking flanges and fibre/NBR gaskets. Maximum working pressure 16.0 bar. Cold water use only.
Range of plastic shower handsets available in various finishes. Maximum operating temperature 65°C.
Concealed, wall mounted elbow fitting with a brass body incorporating EDPM `O`-rings. Maximum working pressure: 10.0 Bar. Maximum operating temperature: 70.0°C.
Range of in-line Y patterned strainers with flanged ductile iron bodies (blue epoxy coated) and stainless-steel mesh strainers. The strainers also incorporate a drain plug. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of in-line Y patterned strainers with flanged ductile iron bodies (blue epoxy coated) and stainless-steel mesh strainers. The strainers also incorporate a drain plug. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Page 29 of 69
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.