Hep2O range of polybutylene fittings for use with Hep2O PB barrier pipe. In May 2024, Next generation (G5) of Hep20 pushfit fittings for use with the Hep20 range of PB barrier pipe, were added to the approval. Maximum working pressure 10.0 bar at 95°C.
Range of press fittings and pipe. Fittings incorporate EPDM ‘O’-rings Maximum working pressure 10 bar. Maximum operating temperature 95°C
Inoxpres range of stainless-steel crimp fittings with EPDM ‘O’-rings and gasket for use with Inoxpres stainless-steel tube (1.4404 AISI 316L or 1.4521 AISI 444 – annealed or not-annealed). The connection is created by using a pressing tool. For above and below ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 95°C.
Instantor Metric Copper Press Range crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Press (TH press profile) and screw/compression fittings with brass bodies for use with Comisa Evo Pipe (PE-RT/AL/PE), for above ground use only. Maximum working pressure 10.0 bar. Maximum operating temperature 99°C.
Range of press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of ‘NiroSan’ stainless-steel crimped fittings incorporating EPDM ‘O’ Rings, for use with ‘NiroSan’, ‘NiroSan SF’ & ‘NiroSan -ECO’ stainless-steel pipe (all manufactured to EN10312). The fittings and pipe are assembled using a crimping tool with either ‘M’ (15-108mm), ‘V’ (15-54mm) or ‘SA’ (15-108mm) crimping profiles. For above ground use only. Maximum working pressure: 16 Bar. Maximum operating temperature: 99°C.
‘BORPLUS’ range of PP-RCT Socket Fusion fittings used with ‘BORPLUS PP-RCT FASER COMPOSITE STABIL’ pipe. Maximum working pressures at 16.0 Bar @ 23°C and 6.0 Bar @ 85°C.
Range of Redman fittings with mild steel bodies (polyamide coating) for use with Puriton II PE-AL-PE barrier pipe - For above and below ground and cold-water use. Jointing is achieved by hydraulic compression. Maximum working pressures: 12.5 Bar for 63mm SDR 11 PE80 pipe system, 10.0 Bar for 90mm to 180mm SDR 17 PE100 pipe system, 16.0 bar for 90mm to 180mm SDR 11 PE100 pipe system. Cold water use only.
IDC ‘BDGxxx’ range of press fittings with brass or nickel plated brass bodies (see model) incorporating EPDM ‘O’-rings and stainless steel crimp sleeves for use with PEX/AL/PEX multilayer pipe (manufactured to EN ISO 21003). The BDG241 and BDG257 prefix models incorporate an EPDM gasket on the captive nut end connection. Pressfit jointing is achieved by either a U or TH crimping profile. Compression connections are for use with copper pipe 12-28mm (manufactured to EN1057) or Irish copper pipe 14.7-27.4mm (manufactured to EN1057). For above ground use only. Maximum working pressure 10.0 bar. 20, 25 & 26mm pressfit sizes cold water use only. Threaded, compression and 16 & 32mm pressfit sizes maximum operating temperature 95°C. From June 2025: The 20, 25 & 26mm pressfit sizes (TH profile only) maximum operating temperature 95°C.
Range of M profile brass press fittings with EPDM ‘O’-rings or gaskets to be used with copper pipe manufactured to EN1057 for above ground use only. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of ‘Isiflo Sprint’ push fit fittings for use with PE100 pipe (manufactured in accordance with EN 12201), for above and below ground use. Isiflo Sprint Family fittings can be installed with seal liners, support liners and without any liner. Maximum working pressure 16 bar. Cold water use only.
Range of copper end feed solder fittings for use with copper tube (EN1057). For above and below ground use. Maximum working pressure for sizes 8mm to 54mm is 25.0 bar. Maximum working pressure for sizes above 54mm is 16.0 bar. Maximum operating temperature 99°C.
Range of plate heat exchangers with pressed stainless steel plate bodies and copper brazing. Available with threaded or flat face seal connection (see model). Maximum working pressure varies by model: ZT190 & ZT207 - 8.0 bar; ZB190, ZB195, ZB200, ZB207 & ZB315 - 10.0 bar; ZC315 (flat face seal version only) - 16.0 bar; ZC190, ZC207, ZC315 (threaded only) & Z(B-C-E) 250, 400, 450, 500 – 30.0 bar or 45.0 bar (models with additional upper and lower plates only); ZB600 & ZB700 - 30.0 bar. Maximum operating temperature 99°C.
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The secondary circuit (DHW) incorporates a plastic flow restrictor and stainless-steel filter. The primary and secondary circuit incorporates isolation valves on the flow and the primary also has one on the return. Maximum working pressures: Secondary DHW: 10.0 Bar Primary CH: 2.5 Bar Maximum operating temperatures: Secondary DHW: 65.0°C Primary CH: 85.0°C
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with isolation valve on both the DHW and CH circuits. The secondary circuit (DHW) incorporates a plastic flow restrictor and stainless-steel strainer. Some models (see model section) are supplied with a filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve. Maximum working pressures: DHW: 10.0 Bar CH: 2.5 Bar Maximum operating temperature: DHW: 65.0°C CH: 85.0°C
Ultrims Ultrasonic range of in-line water meters with brass or plastic (-01 suffix models) bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
‘Helvatron H2O’ range of ultrasonic water meters with brass bodies and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of flow sensors with plastic bodies and rotors. Maximum working pressure: 10 Bar. Maximum operating temperature: 80°C.
Spray handset for personal hygiene (brass bodied - various finishes) incorporating a trigger mechanism controlling the flow. The handset also has a locking ring. The inlet incorporates an approved check valve cartridge with an integral plastic flow regulator; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C.
Page 29 of 45
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.