Appliance inlet group assembly comprising of EPDM gaskets, a plastic bodied Y-pattern strainer, ¾” BSP (F) x ½” BSP (F) brass adaptor, a chrome plated DZR brass bodied double check valve assembly (suitable for backflow protection against Fluid Categry3), a ½” BSP (F) x ¾” BSP (M) brass adaptor, a dual layer hose with a PVC outer (grey) and PVC liner (black), a solenoid valve which incorporates a plastic strainer and a flow regulator within the inlet. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of water meter couplings with black plastic bodies. Maximum working pressure 16.0 bar. Cold water use only
Appliance inlet group assembly comprising of an EPDM gasket, ¾” BSP (F) x ½” BSP (F) brass adaptor, a chrome plated DZR brass bodied double check valve assembly (suitable for backflow protection against Fluid Categry3), a ½” BSP (F) x ¾” BSP (M) brass adaptor, a flexible reinforced hose assembly with a PVC lining and a solenoid valve which incorporates a plastic strainer and a flow regulator within the inlet. Maximum working pressure 5.0 bar. Cold water use only.
Range of hand wash and dryer units The flow is controlled by a solenoid valve activated via an infra-red sensor. The products are supplied with a non-verifiable double check valve assembly (suitable for backflow protection against Fluid category 3) for installation on the inlet. The double check valve assembly also incorporates a drain port, (located in between the cartridges), and an integral spherical valve. Maximum working pressure 10.0 bar. Maximum operating temperature 50ºC.
Pressure gauge with a plastic case, brass connector and bronze spring tube. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Range of booster pumps with stainless steel bodies and impellers (AISI 304: AL-RED models or AISI 316: CP models), EPDM ‘O’-rings and a ceramic/graphite/EPDM shaft seal. Maximum working pressure: CP(m) 100-130-132-150-158 and AL-RED(m) 600-610-620 models: 6.0 bar. All other models: 8.0 bar. Maximum operating temperature 90°C.
Centrifugal pump with a plastic body, plastic impellers and NBR ‘O’-rings. The product includes an (integral) expansion vessel and the inlet incorporates a non-return valve (not suitable for backflow protection). Maximum working pressure 4.5 bar. Maximum operating temperature 50°C.
Single pump units with plastic bodies and impellers, EPDM ‘O’-rings, expansion vessel with an EPDM membrane and a carbon graphite/ceramic/NBR shaft seal (bt-ar 13 bx 4ff xp). Each pump inlet incorporates a non-return valve. Maximum working pressure 10.0 bar. Cold water use only.



Range of shower handsets with plastic bodies and EPDM ‘O’-rings. Maximum operating temperature 65°C.
Range of wall mounted compact shower panels with push button timed flow control. The inlet incorporates a plastic flow regulator and a stainless-steel strainer. Maximum working pressure 4.0 Bar Maximum operating temperature 60°C
Concealed installation set for use with wall mounted overhead shower outlets (brass body – various finishes). The inlet to the shower outlet incorporates a stainless-steel strainer, a plastic flow regulator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of shower arms and outlets with chrome plated brass bodies. The shower outlets incorporate plastic flow regulators at the inlets. Maximum operating temperature 85°C.
Range of shower hoses and handsets (various finishes - see model) with EPDM ‘O’-rings. Maximum operating temperature 60°C.
Range of Y pattern strainers with a bronze body and stainless steel mesh. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.


Pillar tap incorporating a ceramic cartridge headwork (chrome plated brass body) with a single lever operating member. The spout outlet incorporates a flow straightener and flow regulator. The product is supplied with plastic backnuts Maximum working pressure 10 bar. Maximum operating temperature 60°C
Range of pillar taps with brass bodies (various finishes - see model) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The 4102BD18 models incorporate a plastic flow restrictor on the inlet. The products are supplied with plastic and brass backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps with brass bodies (various finishes), incorporating quarter turn ceramic disc headworks with either cross top or single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever, dome type or cross top operating members and plastic backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of pillar taps (chromium plated brass), incorporating quarter turn ceramic disc headworks with single lever, dome type or cross top operating members and plastic backnuts. The spout outlets incorporate a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of self-closing tap assemblies (chrome plated brass) with spring loaded headworks and dome type or single lever (745440 model only) operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with plastic backnuts. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Page 26 of 590
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.