Directory Search Results

Print List

#2010310

Uponor Combi Port range of indirect heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar).Some units have optional ball valve sets. Primary side heating 85°C and 2.5 bar. Secondary side, space heating 60°C and 2.5 bar. Secondary side DHW 60°C and 4.0 bar.

Section:
1350 Heat Exchangers
Size:
See model
Marking:
Uponor, model no, serial no & date of manufacture (DD.MM.YYYY) on inside cover.
Installation Requirements:
R001 R140 R360
Expiry date:
31/10/2025
Model:
Uponor Combi Port base XU: 1095642 15l/min 1095643 21l/min 1095644 29l/min Optional ball valve set 101802 for models 1095644 & 1095642 Uponor Combi Port PRO XU: 1095636 15l.min 1095637 21l/min Optional Ball valve set 1037536
Product Images

Approval Holder:
Uponor GmbH
Company Name
Uponor GmbH
Address
Industriestrasse 56, Hassfurt
Postcode
97437,
Country
Germany
Phone
0034916853600
General Email
mariaisabel.fernandez@uponor.com

View All Listings by this Company

Print This Approval


#2011003

Range of copper brazed, stainless steel heat exchangers in various sizes (4-300 plates, see model). Models size X8T-SC-S Maximum working pressure primary circuit: 32.0 bar Maximum working pressure secondary circuit: 26.0 bar Maximum operating temperature: 99°C Models size 10T-SC-M Maximum working pressure primary circuit: 41.0 bar Maximum working pressure secondary circuit: 36.0 bar Maximum operating temperature: 99°C Models size 15T-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45 bar Maximum operating temperature: 99°C Models size 16DW-SC-S Maximum working pressure primary circuit: 16.0 bar Maximum working pressure secondary circuit: 16.0 bar Maximum operating temperature: 99°C Models size 16DW-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45.0 bar Maximum operating temperature: 99°C Models size 220-SC-S Maximum working pressure primary circuit: 25.0 bar Maximum working pressure secondary circuit: 25.0 bars Maximum operating temperature: 99°C Models size 320HT-SC-S Maximum working pressure primary circuit: 33.0 bar Maximum working pressure secondary circuit: 29.0 bar Maximum operating temperature: 99°C Models size 320LT-SC-S Maximum working pressure primary circuit: 33.0 bars Maximum working pressure secondary circuit: 29.0 bars Maximum operating temperature: 99°C

Section:
1350 Heat Exchangers
Size:
See model
Marking:
SWEP, year of manufacture and technical information on adhesive label on body
Installation Requirements:
R001
Expiry date:
30/11/2025
Model:
Models X8T-SC-S Connection types: ½”, ¾” " External threaded male Number of plates minimum: 4 Number of plates maximum: 60 Models 10T-SC-M Connection types: 3/8” to 1 1/4 " External threaded male Number of plates minimum: 4 Number of plates maximum: 140 Models 15T-SC-M Connection types: ½” to 1” External threaded male Number of plates minimum: 4 Number of plates maximum: 60 Models 16DW-SC-S Connection types: ½” to 1 1/4” External threaded male Number of plates minimum: 4 Number of plates maximum: 140 Models 16DW-SC-M Connection types: ½” to 1 1/4” External threaded male Number of plates minimum: 4 Number of plates maximum: 140 Models 220-SC-S Connection types: 1” to 2 1/2” External threaded male Number of plates minimum: 4 Number of plates maximum: 300 Models 320HT-SC-S Connection types: 1 ½” to 2 1/2” External threaded male Number of plates minimum: 4 Number of plates maximum: 300 Models 320LT-SC-S Connection types: 1 ½” to 3” External threaded male Number of plates minimum: 4 Number of plates maximum: 260
Product Images

Approval Holder:
SWEP International AB
Company Name
SWEP International AB
Address
Järvgatan 3B, Box 105, 26122 Landskrona
Country
Sweden

View All Listings by this Company
Manufacturer:
SWEP Slovakia s.r.o | SWEP Malaysia sdn Bhd
Company Name
SWEP Slovakia s.r.o | SWEP Malaysia sdn Bhd
Address

View All Listings by this Company

Print This Approval


#2011037

Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. Incorporating a pressure relief valve and expansion vessel. Primary circuit has a maximum working pressure of 3.5 bar and operating temperature of 85°C. Secondary circuit has a maximum working pressure of 10.0 bar and operating temperature of 60°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2011037
Note:
A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Size:
½” BSP male inlet and outlet (DHW). ¾” BSP male inlet and outlet (CH).
Marking:
Lukey on adhesive label on front.
Installation Requirements:
R001 R140
Expiry date:
30/11/2025
Model:
Lukey solution HE (18kW CH & 26kW DHW). Lukey solution HE+ (18kW CH & 26kW DHW). Lukey solution HES+ (18kW CH & 26kW DHW). Lukey solution CBU (18kW CH & 26kW DHW). Beginning February 2021 the models will be named: Lukey 28 HE (18kW CH & 26kW DHW). Lukey 28 HE+ (18kW CH & 26kW DHW). Lukey 28 HES+ (18kW CH & 26kW DHW). Lukey 28 CBU (18kW CH & 26kW DHW).
Product Images

Approval Holder:
Lukey Cassette Boilers (UK) Ltd.
Company Name
Lukey Cassette Boilers (UK) Ltd.
Postcode
BH24 2BB

View All Listings by this Company
Manufacturer:
Lukey Cassette Boilers (UK) Ltd.
Company Name
Lukey Cassette Boilers (UK) Ltd.
Postcode
BH24 2BB

View All Listings by this Company

Print This Approval


#2011033

RINNAI range of wall mounted combination boilers.The unit incorporates a stainless-steel plate heat exchanger pressure relief valve set at 3.0 bar and an expansion vessel on the primary circuit. Maximum working pressure of primary circuit is 2.5 bar and secondary circuit is 10.0 bar. Maximum operating temperature 60˚C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2011033
Note:
Not supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Size:
Primary circuit: ¾” (M) BSP inlet and outlet. Secondary circuit: ½” (M) BSP inlet and outlet
Marking:
Rinnai on front. Rinnai, model and technical information on adhesive label on side of unit.
Installation Requirements:
R001 R140 R360
Expiry date:
30/11/2025
Model:
ZEN i24 Combi Boiler – REB-KBI2424FF. ZEN i29 Combi Boiler – REB-KBI2929FF. ZEN i34 Combi Boiler – REB-KBI3535FF.
Product Images

Approval Holder:
Rinnai UK Ltd
Company Name
Rinnai UK Ltd
Address
9 Christleton Court Manor Park Runcom
Postcode
WA7 18T
Phone
01928 531 870
General Email
info@rinnaiuk.com

View All Listings by this Company

Print This Approval


#2011351

Hydroblock unit consisting of a stainless steel heat exchanger, a pressure relief valve pre-set at 3.0 bar, diverter valve and return valve. Maximum working pressure 2.5 bar. Maximum operating temperature 90°C

Section:
1478 Heater
Section Subtitle:
Combination boilers - accessories and components.
WRAS Approval Number:
2011351
Size:
Primary side – ¾” BSP (M) x 18.8mm manifold. Secondary side – ½” BSP (M) x ½” BSP (M)
Marking:
Hydro Zero logo & model on body
Installation Requirements:
R001
Expiry date:
30/11/2025
Model:
Hydroblock HB-112
Product Images

Approval Holder:
Hydro Zero Ltd.
Company Name
Hydro Zero Ltd.
Postcode
LS28 9LE

View All Listings by this Company

Print This Approval


#2010326

Hygienic flush box providing a timed flush facility. The supply is via a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection, flow sensor, spherical ball valve and strainer. The products incorporate a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). The units have multiple interface user functions for timed flush, wireless technology and data storage. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
1530 Miscellaneous Fittings
Size:
¾” BSP (M).
Marking:
Kemper, manufacturers address DN15 and other technical info on adhesive label. Kemper on front.
Installation Requirements:
R001 R520 R574
Expiry date:
31/10/2025
Model:
689 03 005 KHS Hygiene Flush Box PURE 689 03 006 KHS Hygiene Flush Box PURE 689 03 007 KHS Hygiene Flush Box PRO with flow sensor 689 03 008 KHS Hygiene Flush Box PRO with flow sensor 689 03 009 KHS Hygiene Flush Box LITE with flow sensor 689 03 010 KHS Hygiene Flush Box LITE with flow sensor
Product Images

Approval Holder:
Gebr. Kemper GmbH + Co. KG
Company Name
Gebr. Kemper GmbH + Co. KG
Address
Harkortstr. 5 57462 Olpe Germany
Phone
+49(0) 27618910
General Email
info@kemper-olpe.de

View All Listings by this Company

Print This Approval


#2010338

Maincor Manifold having a brushed chrome plated body with 2 ,3 or 4 ports each with an isolation valve with red or blue indicators for hot and cold feeds. Supplied with a blanking plug and nut. Maximum working pressure 6.0 bar. Maximum operating temperature 75°C.

Section:
1530 Miscellaneous Fittings
Size:
See model.
Marking:
Maincor, year of manufacture (YYYY) & made in Italy on body.
Installation Requirements:
R001
Expiry date:
31/10/2025
Model:
Maincor Manifold 1” – ¾” BSP (M) outlets. Maincor Manifold ¾” – ½” BSP (M) outlets.
Product Images

Approval Holder:
Maincor
Company Name
Maincor
Address
Leciester Road, Lutterworth, Leicestershire
Postcode
LE17 4NJ
Phone
+44 (0) 1455 555930
General Email
enquiries@maincor.co.uk

View All Listings by this Company

Print This Approval


#2009051

Range of in-line plastic flow regulators. The flow regulator is housed within a black plastic body incorporating a plastic strainer and an EPDM ‘O’-ring. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.

Section:
1530 Miscellaneous Fittings
Size:
¾” BSP (M)
Marking:
Flow arrow, flow rate, HL2024 (brand of HGP), connection size and connection type on adhesive label on body. Flow arrow on body.
Installation Requirements:
R001
Expiry date:
30/09/2025
Model:
HL2024 Inline Cartridge 3P 3-4 EC EP. HL2024 Control Flow 3P 3-4 EC EP. HL2024 Inline Cartridge 3P 3-4 FL EP. HL2024 Control Flow 3P 3-4 FL EP. Where: EC = BSPP ¾” Euroconus. FL = BSPP ¾” Flat Faced.
Product Images

Approval Holder:
HaGePe International B.V (HGP International)
Company Name
HaGePe International B.V (HGP International)
Address
Huizermaatweg 27-2 1273 NA Huizen
Country
Netherlands

View All Listings by this Company
Manufacturer:
HaGePe International B.V (HGP International)
Company Name
HaGePe International B.V (HGP International)
Address
Huizermaatweg 27-2 1273 NA Huizen
Country
Netherlands

View All Listings by this Company

Print This Approval


#2010079

Range of water monitoring systems comprising of a battery or mains operated latching solenoid valve (plastic body) and a flow sensor. The units are supplied with a hand-held controller. Maximum working pressure 10.0 bar. Cold water use only.

Section:
1530 Miscellaneous Fittings
WRAS Approval Number:
2010079
Note:
This product has not been tested or approved for anti-flooding claims made by the approval holder. R008 applies to the water contact parts and not the hand-held controller.
Size:
¾” BSP (M)
Marking:
Aqualeak & Aquaguard logo on handset.
Installation Requirements:
R001 R008
Expiry date:
31/10/2025
Model:
AG22001PS Aquaguard 22mm WRAS with power supply. AG22001 Aquaguard 22mm WRAS Battery operated.
Product Images

Approval Holder:
Aqualeak Detection Ltd
Company Name
Aqualeak Detection Ltd
Postcode
SN15 3RS
Phone
+44 (0)1249 715 698

View All Listings by this Company

Print This Approval


#2102700

Range of flow measurement devices (DZR brass) bodies incorporating two test ports. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.

Section:
1530 Miscellaneous Fittings
Size:
See model.
Marking:
Crane, size, PN, CR, model and flow arrow on body.
Installation Requirements:
R001
Expiry date:
28/02/2026
Model:
D901 & 902: Inlet: ½” screwed ISO 228 parallel BSPP (F). Outlet: ½” taper threaded to BS EN 10266-2 BSPT (M). D901: Inlet: ¾”, 1”, 1¼”, 1½” or 2” taper threaded BS EN 10226-2 BSPT (F). Outlet: ¾”, 1”, 1¼”, 1½” or 2” taper threaded BS EN 10226-2 BSPT (M).

Approval Holder:
Crane Ltd
Company Name
Crane Ltd
Address
Crane House, Epsilon Terrace, West Road, Ipswich
Postcode
IP3 9FJ
Country
United Kingdom
Phone
01473 277 364
General Email
tturner@cranebsu.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 25 of 1016

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.