Directory Search Results

Print List

#250702719

Range of WC dual flush drop valves with ABS bodies and silicon seals. The valves are operated via a push button assembly for either full or reduced flush and incorporate an internal, adjustable height overflow.

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not been verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
250702719
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Note:
Open outlet and cold water use only.
Size:
1 1/2" BSP (M) (MFV1C and MFV2C) 2" BSP (M) (MFV3C and MFV4C)
Marking:
Multikwik website and NSG3338 on body or Multikwik Website on base of flush valve
Installation Requirements:
R001 R556 R571
Expiry date:
31/07/2030
Model:
0702120 MFV1C 0702121 MFV2C 0702122 MFV3C 0702123 MFV4C

Print This Approval


#250702708

Range of heat interface units providing heating and instantaneous hot water. The central heating and hot water are generated via plate heat exchangers. The central heating circuit contains a pressure relief valve (3.0 bar) and an expansion vessel. The cold inlet supply to the plate heat exchanger incorporates an in line single check valve assembly, (suitable for backflow protection against Fluid Category 2). Max Temperature & Pressure for models A/7892284 & B/7892283: Primary Circuit: 6.0 bar at 90°C DHW Circuit: 10.0 bar at 55°C Secondary Circuit 6.0 bar at 90°C Max Temperature & Pressure for all other models: Primary Circuit: 16.0 bar at 90*C, DHW Circuit: 10.0 bar at 65*C, Secondary Circuit 3 bar at 85*C.

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
3/4" BSP (F) captive nut connections
Marking:
Baxi on front cover, Baxi, product info on label on front cover
Installation Requirements:
R001
Expiry date:
31/07/2030
Model:
A/7892284 AquaHeat HD/HWI 12/50 with Heat Meter & Mercurius B/7892283 AquaHeat HD/HWI 12/50 Models added September 2025: 7867470 AquaHeat HI/HWI 4/50 with Heat Meter & Mercurius, 7867472 AquaHeat HI/HWI 4/50, 7867574 AquaHeat HI 50 with Heat Meter & Mercurius, 7867575 AquaHeat HI 50, 7867476 AquaHeat HI/HWI 14/50 with Heat Meter & Mercurius, 7867477 AquaHeat HI/HWI 14/50.

Approval Holder:
Baxi Heating UK Limited
Company Name
Baxi Heating UK Limited
Address
Brooks House, Coventry Road, Warwick
Postcode
CV34 3LL

View All Listings by this Company
Manufacturer:
Baxi Heating UK Limited
Company Name
Baxi Heating UK Limited
Address
Brooks House, Coventry Road, Warwick
Postcode
CV34 3LL

View All Listings by this Company

Print This Approval


#250702712

Mini expansion vessels/shock arrestor with a stainless-steel body and butyl rubber diaphragm. Maximum working pressure 10.0 bar. Cold water use only.

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (M).
Marking:
TRAPPEX on adhesive label on body.
Installation Requirements:
R001
Expiry date:
31/07/2030
Model:
TRAPSHOCK12 (TRAPPEX CENTRASHOCK 2).

Approval Holder:
Trappex Ltd.
Company Name
Trappex Ltd.
Address
59 Springwood Hall Gardens, Huddersfield
Postcode
HD1 4HA
Country
United Kingdom
General Email
info@trappex.co.uk

View All Listings by this Company

Print This Approval


#250704708

Shock arrestors with a copper body, plastic shuttle and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
WHA-G12M-LL: ½” BSP (M), WHA-G34M-LL: ¾” BSP (M), WHA-G1M-LL: 1” BSP (M), WHA-AM-LL: ½” NPT (M), WHA-BM-LL: ¾” NPT (M), WHA-CM-LL: 1” NPT (M).
Marking:
Yongtong logo, Yongtong, part # (model), size (A, B or C), water hammer arrestor, WRAS and made in China on adhesive label on body.
Installation Requirements:
R001
Expiry date:
31/07/2030
Model:
WHA-G12M-LL: 1/2” G Male Water Hammer Arrester, A, WHA-G34M-LL: 3/4” G Male Water Hammer Arrester, B, WHA-G1M-LL: 1” G Male Water Hammer Arrester, C, WHA-AM-LL: 1/2” MIP Water Hammer Arrester, A, WHA-BM-LL: 3/4” MIP Water Hammer Arrester, B, WHA-CM-LL: 1” MIP Water Hammer Arrester, C.

Approval Holder:
Taizhou Yongtong Brass Industry Co., Ltd.
Company Name
Taizhou Yongtong Brass Industry Co., Ltd.
Address
50 Keyuanbei Road, Qinggang, Yuhuan, Zhejiang
Country
China
Phone
+86 0576-87105707
General Email
j.luo@yongtongbrass.com

View All Listings by this Company

Print This Approval


#250302723

Range of multistage centrifugal pumps with stainless steel impellers, intermediate chambers, shaft and outer sleeve. The DPV(M/S) models and DPV(S) models can also incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressures: Existing models: DPV models 10.0 bar, DPVM models with an oval flange or VME models with integral check valve 16.0 bar, All other DPVM models 25.0 bar. DPV(S) models with an oval flange or DPV(S)(E) models with integral check valve 16.0 bar, All other DPV(S) models and DPH(S)I models 25.0 bar. Maximum operating temperatures: DPHM, DPVE and DPVME models with integral check valve 60°C, all other model variants 100°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
250302723
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
DPHM 2/4/6 B: 1¼” BSP (F) inlet x 1” BSP (F) outlet. DPV(M/S)(F/E/V/T) 2/4/6 B: Oval flange: DN25, DN32. Round flange: DN25, DN32. External threaded: 1½” BSP (M), Victaulic: DN32 and Tri-clamp: DN32. DPV(S) (F/E/V/T) 10 B/15 B/15 C: Oval flange: DN40, DN50. Round flange: DN40, DN50. External threaded: 1½” BSP (M), Victaulic: DN50 and Tri-clamp: DN50. DPV(S)F 25/40/60/85/125 B: Round flange: DN65, DN80, DN100, DN125. DPH(S)I 2/4/6 B: 1¼” BSP or NPT (F). DPH(S)I 10/15 B/C: 2” BSP or NPT (F).
Marking:
DPVF & logo, model name, PN, WRAS and technical information on adhesive label on body.
Installation Requirements:
R001 R415
Expiry date:
31/03/2030
Model:
DPHM x yy B. Where: x = flow rate m³/h (2, 4 or 6). yy = no. of stages ranges 1-6 stages. ------------------------------------- DPV(M/S)(F/E/V/T) x yy B/C Where: V = Vertically oriented (AISI 304) with coupling. VS = Vertically oriented (AISI 316) with coupling. No indication (V/VS only) = oval flange. F (VF/VSF) = round flange. E (VE) = external thread. V (VV/VSV) = Victaulic. T (VT/VST) = Triclamp. x = flow rate m³/h (2, 4, 6, 10, 15). yy = no. of stages DPV(M/S)(F/E/V/T)……2 B 1-30 stages. DPV(M/S)(F/E/V/T)……4/6 B 1-26 stages. DPV(S)(F/E/V/T)……10 B 1-21 stages. DPV(S)(F/E/V/T)……15 B/C 1-17 stages. -------------------------------------- DPV(S) F xx yy B. Where: V = Vertically oriented (AISI 304) with coupling. VS = Vertically oriented (AISI 316) with coupling. F (VF/VSF) = round flange. x = flow rate m³/h (25, 40, 60, 90(model 85) or 125). yy = no. of stages ……25 B 1-12 stages. ……40/60 B 1-10 stages. ……85 B 1-6 stages. ……125 B 1-4 stages. -------------------------------------- DPHI x yy = Vertically oriented (AISI 304). DPHSI x yy = Vertically oriented (AISI 316). Where: I = Inner thread connection. x = flow rate m³/h (2, 4, 6, 10 or 15). yy = no. of stages DPH(S)I 2/4/6 B 1-14 stages. DPH(S)I 10 B/15 B/15 C 1-8 stages.

Approval Holder:
Duijvelaar Pompen B.V.
Company Name
Duijvelaar Pompen B.V.
Address
Kalkovenweg 13 2401 LJ Alpen aan den Rijn
Country
Netherlands
Phone
0031 0172 488388

View All Listings by this Company

Print This Approval


#250504008

Range of (chrome plated) plastic shower handsets with flexible shower hose and stainless-steel braided connection hose. The inlet incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C. Open outlet use only.

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
250504008
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Note:
R009 only applied to the flexible braided inlet hose that connects to the shower hose.
Size:
½” BSP (F) captive nut.
Marking:
Gessi Emporio etched on face plate.
Installation Requirements:
R001 R009 R040
Expiry date:
31/05/2030
Model:
47227, 47127.

Approval Holder:
Gessi S.p.A.
Company Name
Gessi S.p.A.
Address
Parco Gessi Hamlet Vintebbio Serravalle Sesia
Postcode
13037
Country
Italy
Phone
+39 0163 454111
General Email
pfornara@gessi.it

View All Listings by this Company

Print This Approval


#250702048

Range of draining taps, straight or elbowed with brass bodies incorporating a rising spindle headwork. Maximum working pressure 10.0 Bar Maximum operating temperature 95.0°C

Section:
1770 Taps
Section Subtitle:
Draining, for above ground use only.
WRAS Approval Number:
250702048
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
See models
Marking:
IDC E logo and size on body. size and EN number on nut
Installation Requirements:
R001
Expiry date:
31/07/2030
Model:
BF8712 Elbow Drain off Mi x C Compression x Male 3/4”Mx 21mm BF8713 Elbow Drain off Mi x C Compression x Male 1”M x 27.4mm BF4712 Elbow Drain off compression 21mm x 21mm BF4713 Elbow Drain off compression 27.4mm x 27.4mm BF1711 Straight Drain off compression 14.7mm x 14.7mm BF1712 Straight Drain off compression 21mm x 21mm BF1713 Straight Drain off compression 27.4mm x 27.4mm

Approval Holder:
IDC Plumbing & Heating Technology (Beijing) Co., Ltd.
Company Name
IDC Plumbing & Heating Technology (Beijing) Co., Ltd.
Address
3rd Floor, Unit 2, Building 2, Section A Zhaowei Science & Technology Park No. 14, Jiuxianqiao Road Chaoyang District Beijing
Postcode
100015
Country
China
Phone
008610 51659550 ext 312
General Email
Jerry.tang@idcgroup.com.cn

View All Listings by this Company
Manufacturer:
Zhejiang IDC Fluid Control Co Ltd
Company Name
Zhejiang IDC Fluid Control Co Ltd
Address
Machinery Industrial Park Zhugang Town Yuhuan County
Country
Zhejiang
General Email

View All Listings by this Company

Print This Approval


#250704016

Range of wall mounted self-closing pillar taps (chromium plated brass), incorporating a spring-loaded headwork with a dome type operating member. The spout outlet incorporates a plastic aerator and the products are supplied with metal backnuts. Maximum operating pressure 10 bar. Maximum operating temperature 65°C

Section:
1820 Taps
Section Subtitle:
Self closing tap(s).
WRAS Approval Number:
250704016
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (M)
Marking:
Presto on operating member.
Installation Requirements:
R001 R040
Expiry date:
31/07/2030
Model:
66000 66100 66010 66012

Approval Holder:
Les Robinets Presto S.A
Company Name
Les Robinets Presto S.A
Address
4 Rue Lavoiser St. Georges De Didonne
Postcode
17110
Country
France
Phone
+33 546 053 452
General Email
l.granseigne@presto.fr

View All Listings by this Company

Print This Approval


#250712008

Range of air venting valves with brass bodies. The P0508.015 compression model is for use with copper pipe (manufacturer to EN 1057) Maximum working pressure: 10.0 bar. Maximum operating temperature 85°C.

Section:
1980 Valves
Section Subtitle:
Air venting. Fittings in this section are suitable for above ground installations only.
WRAS Approval Number:
250712008
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
P0507.G15: ½” BSP (M), P0508.015: 15mm compression.
Marking:
Zhejiang Fansheng Fluid Control Co., Ltd logo, pressure and temperature on cap. P0508.015 model also includes size and EN1254-2 on compression nut.
Installation Requirements:
R001
Expiry date:
31/07/2030
Model:
P0507.G15, P0508.015.

Approval Holder:
Zhejiang Fansheng Fluid Control Co., Ltd.
Company Name
Zhejiang Fansheng Fluid Control Co., Ltd.
Postcode
317605
Country
China
Phone
+86 576 8746 0061
General Email
info@IVANCI.com

View All Listings by this Company

Print This Approval


#250713002

Range of wall mounted, concealed, manually operated blending valves with (brass bodies - various finishes), incorporating ceramic cartridge or quarter turn ceramic disc headworks and single lever or dome type operating members. Maximum working pressure 5.0 Bar Maximum operating temperature 70 °C.

Section:
2000 Shower Valves
Section Subtitle:
Shower valve(s) with manual temperature control.
WRAS Approval Number:
250713002
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (F)
Marking:
Gessi on operating member
Installation Requirements:
R001 R040
Expiry date:
31/07/2030
Model:
19710 & 38312 Emporio Shower mixer. 66132 & 54169 Origini Shower mixer
Product Images

Approval Holder:
Gessi S.p.A.
Company Name
Gessi S.p.A.
Address
Parco Gessi Hamlet Vintebbio Serravalle Sesia
Postcode
13037
Country
Italy
Phone
+39 0163 454111
General Email
pfornara@gessi.it

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 199 of 247

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.