Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with a temporary filling loop which incorporates a combined isolation valve and double check valve assembly (suitable for backflow protection against Fluid Category 3), stainless steel braided EPDM lined flexible hose assembly and an isolation valve. The secondary circuit (DHW) incorporates a stainless-steel strainer. The primary circuit incorporates isolation valves on the flow and return. Maximum working pressures: DHW: 10.0 Bar CH:2.5 Bar Maximum operating Temperatures: DHW: 65.0°C CH: 85.0°C
Range of ultrasonic water meters with plastic bodies. The inlet incorporates a plastic strainer. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
‘Sonata’ range of water meters with plastic or brass/plastic bodies. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
Range of inline water meters with blue epoxy coated cast iron body. Maximum working pressure 16.0 bar. Cold water use.
Range of pressure, flow and temperature sensors. The VFI sensors have stainless steel bodies, all other models have plastic bodied sensors. The MFS and VFS models are supplied with a plastic (composite) or stainless-steel flow pipe. The VFI models are supplied with a stainless-steel flow pipe. The products can also be supplied with a range of fittings/end connections (see model and size). Maximum working pressures: ITS, LPS, RPS, MFS (composite flow pipe) and VFS (composite flow pipe) models: 24.0 bar. CPS models (added February 2024): 24.0 bar. DPS: Models with vent hole: 16.0 bar. All other models: 24.0 bar. MFS (stainless steel flow pipe) and MFS (stainless steel flow pipe): 30.0 bar. VFI non-flanged models: 30.0 bar. VFI flanged models: 30.0 bar or as per flange PN rating 16.0 bar or 25.0 bar (whichever is lower). Maximum operating temperature 99°C.
Range of temperature measurement devices with bronze bodies and EPDM o-rings. Maximum operating pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Flow meter with stainless steel body. Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
‘AQ tap’ water dispensing unit incorporating a brass solenoid and a flow sensor. The unit is operated using a smart card and credit system that allows the user to obtain a set amount of water. Maximum working pressure 3.0 bar. Cold water use only.
Range wall mounted elbows (XX 1799 YY & XX E 1799 YY) and compression (XX 1749 YY & XX 1825 YY) fittings with brass bodies (various finishes, see models). Open outlet use only.
Non-metallic materials and components comply with BS6920 at 65°C
Permanent magnet variable frequency multistage pump with plastic bodies, plastic impellers, stainless steel shaft and EPDM ‘O’-rings. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 50°C
CMBE range of horizontal multistage centrifugal booster pumps with stainless steel bodies and impellers and EPDM ‘O’-rings. All models include an expansion vessel, non-return valve, pressure gauge and sensor on the outlet. Maximum working pressure 10.0 bar. Cold water use only.
Wall mounted shower outlet (brass body – various finishes). The product is supplied with shower hose and handset that incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower heads with chromium plated ABS bodies. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 75°C
Range of overhead showers consisting of stainless steel bodies and silicone nozzles and gaskets and shower handsets consisting of ABS (LB-2003N, LB-2003, LB-2004) or brass bodies (LB-2006 & LB-2028).
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower handsets & overhead shower outlets with chromium plated plastic body. The inlets of the overhead shower outlets incorporate a stainless-steel strainer.
Non-metallic materials and components comply with BS6920 at 60°C
Range of overhead shower outlets with (brass bodies – various finishes), incorporating EPDM `O`-rings and a plastic strainer. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of overhead shower outlets with brass or stainless-steel bodies (various finishes - see model), with NBR ‘O’-rings. The inlet incorporates a stainless-steel strainer.
Non-metallic materials and components comply with BS6920 at 70°C
Range of hand showers with (plastic bodies - various finishes). The products incorporate a stainless-steel strainer and flow regulator. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Wall mounted and ceiling mounted shower arms (chromium plated brass).
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower kits comprising of a chrome plated brass handset, shower hose and riser rail.
Non-metallic materials and components comply with BS6920 at 85°C
Page 188 of 522
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.