‘PREMIX’ range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both the domestic hot water and primary circuit are controlled via spherical valves. Maximum working pressures: Primary circuit: 2.5 bar, Secondary circuit 10.0 bar. Maximum operating temperature both circuits: 80°C.
Range of ultrasonic remote transmission water meters with stainless steel body. The products incorporate a single check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Range of rotating piston, volumetric in-line water meters with brass bodies. Maximum working pressure 16.0 bar. Cold water use only.
Range of water meters with either cast iron (blue epoxy coated) or stainless-steel bodies, transducers and EPDM rubber O-rings. Maximum working pressure 25.0 Bar. Maximum operating temperature 50.0°C.
Range of leak detection devices incorporating a DZR brass body and non-return valve (not intended for and not suitable for backflow protection). Models Stopleak 1 & Stopleak 2 incorporate a spherical valve. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Water hammer arrestor with brass body and EPDM ‘O’ ring. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of single stage booster pumps incorporating a flow switch. Model 46349 CH 12-14 B is supplied with a pressure vessel and incorporates an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with a strainer and stainless-steel braided EPDM lined flexible connection hoses. Maximum working pressure 6.0 bar. Maximum operating temperature 65°C.
shower handset with chrome plated body. Open outlet use only Maximum operating temperature 85°C
Shower handset with plastic body. Maximum operating temperature 85C Open outlet use only
Non-metallic materials and components comply with BS6920 at 70°C
Chrome plated brass shower handset. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Shower outlet kit, consisting of chromium plated ABS shower handset and PVC lined shower hose. The kit is also supplied with a riser rail and handset retainer. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of adjustable ceiling and wall mounted shower arms available with brass bodies (various finishes). Maximum operating temperature 85°C.
Range of overhead shower outlets with brass bodies (various finishes). The products incorporate a plastic flow regulator. Models listed are to be used in conjunction with the 26 471 180 basic set. Maximum operating temperature 65°C.
Range of shower outlets comprising of shower heads all incorporating stainless-steel strainer washers (plastic bodies-various finishes) and handheld showers (plastic bodies - various finishes). Maximum operating temperature 75°C.
Range of overhead shower and shower handsets with (brass or plastic bodies – various finishes), incorporating a stainless-steel strainer on the inlets. Open outlet use only Maximum operating temperature – 85°C.
Range of shower arms, (stainless steel bodies – various finishes). Open outlet use only. Maximum operating temperature - 85°C
Range of shower handsets with (plastic bodies - various finishes) incorporating a plastic flow restrictor in the inlet. Open Outlet use only Maximum operating temperature 60.0°C
Range of overhead shower outlets with Various finishes. The inlets incorporate a stainless-steel strainer and flow regulator. Models 64400250CH, 67400250BBL, 63400250BBR, 68400250MB & 61400250BRZ Incorporates a shower arm.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower outlets with chromium plated bodies. Products have check valves fitted at the inlets however, the complete products have not been fully tested to demonstrate they provide backflow prevention. From July 2023, model P61400 can also be supplied without the check valve at the inlet. Maximum operating temperature 70°C.
Range of ‘Y’-pattern strainers with blue epoxy coated ductile iron bodies and a stainless-steel screen. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Flow sensor with a plastic and brass body. Maximum working pressure 16.0 bar. Maximum operating temperature 80°C.
Range of drain valves with a brass bodies, spindle and EPDM ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Range of wall mounted hose union bib taps incorporating a rising spindle headwork with a T - handle operating member. Model 13.20202.G15.CP5R-8511 has a DZR brass body, all other models have a brass body. Model 13.20252.G15.CP5R-8510 incorporates a lockshield device at the base of the operating stem. The spout outlets incorporate a hose union connector. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Wall mounted hose union tap brass body incorporating a non-rising spindle headwork with a lock shield and removable butterfly handle operating member. The spout outlet incorporates a hose union connector. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of pillar taps with (brass bodies - various finishes) incorporating a quarter turn ceramic disc headwork with dome type operating members. The spout outlet incorporates a plastic aerator. Maximum operating pressure 10 bar. Maximum operating temperature 60°C
Range of pillar taps (brass bodies – various finishes) incorporating a quarter turn ceramic disc headwork with a single lever or cross top operating member. The product is supplied with metal backnuts. Maximum working pressure 5.0 Bar. Maximum operating temperature 85°C.
Range of pillar taps, incorporating a non-rising spindle headwork with cross top or dome type operating members. The spout outlet incorporates a plastic flow straightener, and the product is supplied with metal back nuts. All taps are supplied with an optional flow regulator. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of pillar taps (chrome plated brass bodies) incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps, (chrome plated brass bodies) incorporating non-rising spindle headworks with dome or cross-top type operating member. Model (C02065) incorporates a quarter turn ceramic disc headworks with single lever operating members. The spout outlets incorporate plastic flow straighteners. The product is supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of pillar taps (chromium plated brass) incorporating non-rising spindle headwork with cross top operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with metal backnuts. Maximum working pressure 7.0 bar. Maximum operating temperature 65°C.
Range of pillar taps (chrome plated brass bodies), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straighteners. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of stainless-steel interlocked shower hoses and shower hose extension pieces (smaller length versions) incorporating PE/EPDM and PEX inner tube materials. Available with various surface finishes and end connectors. For further details see model section. Maximum working pressure open outlet use. Maximum operating temperature 85.0°C
Range of stainless steel inter-locked shower hoses incorporating PVC linings in various finishes. Maximum operating temperature 65°C.
Range of Compress 5800i AW vertical cased and insulated indirect unvented stainless steel hot water storage cylinders fitted with a Caleffi 309508 CST temperature and pressure relief valve set at 10 bar & 90°C, and supplied with a Caleffi inlet control group consisting of in-line pressure reducing valve (set at 3.5 bar) and pressure relief valve (set at 6 bar) and incorporates an approved check valve cartridge (verified by test suitable for backflow protection against Fluid Category 2). The cyclinders also supplied with an 18L expansion vessel and Intatec filling loop assembley (FL12041510). Maximum working pressure 10 bar. Maximum operating temperature 80°C.
Range of air venting valves with blue epoxy coated ductile iron bodies and a plastic float. Maximum working pressure16.0 bar. Cold water use only.
Range of wall mounted concealed, manual blending valves with a brass body (various finishes), incorporating a ceramic cartridge headwork with a single lever type operating member. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of wall mounted bar type shower mixing valve (brass body, various finishes - see model). The product incorporates a ceramic cartridge headwork with a single lever operating member. The hose outlet incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of T-type thermostatic blending valves with nickel plated brass bodies and EPDM ‘O’-rings. The inlet and outlet incorporate an approved check valve cartridge ((verified by test - suitable for backflow protection against fluid category 2). Models with compression ends are to be used with copper pipe EN1057. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of concealed, wall mounted thermostatic blending valves with brass bodies (chromium plated trim sets). The products consist of a two-way diverter and a thermostatic cartridge controlling the temperature. All models incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5 bar. Maximum operating temperature 60°C.
Range of T-type thermostatic blending valves with DZR brass bodies. Maximum working pressure 14.0 bar. Maximum operating temperature 90°C.
Range of T-type thermostatic mixing valves with DZR brass bodies. Maximum working pressure 14.0 bar. Maximum operating temperature 100°C.
Range of wall mounted thermostatic bar shower mixers (chrome plated brass bodies), incorporating ceramic disc diverter valve controlling the flow with a cubed type operating member. The temperature is controlled independently via a thermostatic cartridge with a cubed type operating member that incorporates a manual override button. The inlets incorporate stainless-steel strainer washers and approved single check valve cartridges (however, the complete product has not been fully tested to demonstrate that it provides backflow protection). Products are supplied with shower handset, shower hose, overhead shower and riser rail assembly. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted concealed thermostatic shower valves (brass bodies – various finishes) incorporating a manual diverter to shower outlets and quarter turn ceramic disc headwork controlling the flow with dome type operating members. Temperature is controlled independently via a thermostatic cartridge with dome type operating member. Both inlets incorporate approved single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 75°C
Range of wall mounted bar type thermostatic shower valves (brass bodies – various finishes) incorporating quarter turn ceramic disc headwork which controls the flow with dome type operating members. Temperature is controlled independently via a thermostatic cartridge with dome type operating member which incorporates a manual override button. Both inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an optional flow regulator. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C
Range of wall mounted bar type thermostatic shower valves (brass bodies – various finishes) incorporating ceramic disc headwork which controls the flow to 2 outlets with dome type operating members. Temperature is controlled independently via a thermostatic cartridge with dome type operating member which incorporates a manual override button. Both inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an optional flow regulator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C
Range of wall mounted bar type thermostatic shower valves (brass bodies – various finishes) incorporating quarter turn ceramic disc headwork which controls the flow with dome type operating members. Temperature is controlled independently via a thermostatic cartridge with dome type operating member which incorporates a manual override button. Both inlets incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an optional flow regulator. Maximum working pressure 5.0 bar. Maximum operating temperature 85°C
Range of wall mounted, thermostatic bar shower mixers (brass bodies – various finishes), incorporating a quarter turn ceramic disc headwork that controls the flow with a dome type operating member. Temperature is controlled independently via a thermostatic cartridge with dome type operating member that incorporates a manual override button. Models 483841 incorporate a half turn ceramic disc headwork that diverts the flow to an overhead shower or shower handset. Both inlets incorporate an approved check valve cartridge and stainless steel strainers however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models 248683 & 287697 Maximum working pressure 10 bar. Maximum operating temperature 65 C. Model 483841 Maximum working pressure 5 bar. Maximum operating temperature 60 C.
Range of T-type thermostatic mixing valves with brushed chrome plated DZR brass bodies. Each inlet incorporates a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) and stainless-steel strainers. Compression connections are for use with copper pipe (manufactured to BS EN1057). Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Wall mounted thermostatic shower valve (chrome plated brass), incorporating a non-rising spindle headwork controlling the flow and a thermostatic cartridge independently controlling the temperature, both using single lever operating members. The inlets incorporate flow regulators, plastic strainers and approved single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. Products are supplied with a chrome plated shower handset, shower hose and riser rail assembly. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of exposed wall mounted thermostatic shower valves, (chrome plated brass bodies). Both inlets incorporate flow regulators and approved check valve cartridges, (however, the complete product has not been fully tested to demonstrate that it provides backflow protection). Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Page 185 of 225
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.