Range of three-hole, single outlet (fixed) combination tap assemblies (brass bodies – various finishes). Incorporating a ceramic cartridge headwork with a single lever operating member and self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator. The product is supplied with metal backnuts Maximum working pressure 10.0 Bar. Maximum operating temperature 60 °C
Range of single hole, double outlet (swivel) combination tap assemblies (various finishes) with electronically controlled functions to allow the tap to dispense boiling water, chilled water or sparkling water from under counter units (not supplied or part of this approval) and a ceramic cartridge headwork with single lever operating member controlling the flow of normal mixed water. The spout outlet incorporates a plastic aerator. Maximum working pressure: 5.0 Bar. Maximum operating temperature: 98.0°C.
Range of wall mounted bath spout outlets with brass bodies (various finishes) with a plastic aerator incorporated into the outlet. Maximum working pressure: 5 bar. Maximum operating temperature 60°C
Mini shock arrestor with a stainless steel body. Maximum working pressure 15.0 bar . Maximum operating temperature 70°C.
Range of expansion vessels with white epoxy coated steel bodies and butyl diaphragm. Please refer to model for maximum working pressures. Maximum operating temperature 70°C. Maximum working pressure 10.0 bar (all except two models), 8.0 bar (24749 & 24809 only).
Range of shock arrestors comprising of a copper tube and brass adapter. Max working pressure 10.0 Bar. Max working temperature 80°C.
Range of copper press fittings (‘M’ type crimp profile) and brass threaded adaptor fittings, for use with copper pipe (EN1057). Maximum operating pressure - 16 bar @ 30°C and 10 bar @ 95°C.
Range of press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
Range of “JRG Sanipex MT” compression fittings with EPDM ‘O’-rings for use with “JRG Sanipex MT ECO” multilayer pipes (PE-RT II/Al/PE-RT II). Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of plastic pushfit fittings for use with ‘Bevex’ polypropylene pipe. Maximum working pressure 6.5bar. Cold water use only.
‘ZL’ range of U profile press fittings (nickel plated brass bodies) for use with ‘ZL’ range of PERT/AL/PERT multi-layered pipes. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
NovaTherm range of U profile press fittings (nickel plated brass bodies) for use with NovaTherm range of PERT/AL/PERT multi-layered pipes. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
B Profile range of 316L & 304 stainless steel press fittings with EPDM ‘O’-rings for use with stainless steel pipe manufactured to EN 10312, for both above and underground use. Joints are achieved by the use of a press fitting tool. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C.
Range of R-154 stainless steel pressed collars incorporating stainless steel bodies (304L or 316L) and are only to be used with stainless steel pipe. Maximum working pressure for sizes up to DN150 (FCM models) or DN125 (FCI models) is 25.0 bar. Maximum working pressure for size DN200 (FCM models) or DN150 and DN200 (FCI models) is 16.0 bar. Maximum operating temperature 99°C.
Silicon Bronze bodies Press Fittings with EPDM `O`-rings. For use with copper pipe manufactured in accordance with BS EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
Copper press-fit fittings with copper with EPDM `O`-rings. For use with copper pipe manufactured in accordance with BS EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 99°C.
FLOMASTA range of polypropolene fittings for use with PE pipe (manufactured to EN 12201). Maximum working pressure 16 bar. Cold water use.
Indirect heat interface unit with copper brazed, stainless-steel heat exchangers, providing heating and instantaneous hot water. The product incorporates an expansion vessel on the cold-water supply to the plate heat exchanger and a safety relief valve on the heating circuit set @ 2.5 bar. The DHW and heating circuits are both fitted with drain valves incorporating cover caps. Maximum working pressure 16 Bar (Primary), 10 Bar (DHW) & 3 Bar (Heating) Maximum operating temperature 95°C
‘PREMIX’ range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both the domestic hot water and primary circuit are controlled via spherical valves. Maximum working pressures: Primary circuit: 2.5 bar, Secondary circuit 10.0 bar. Maximum operating temperature both circuits: 80°C.
Range of in-line water meters with brass bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.
Page 164 of 204
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.