Dual flush drop valve incorporating two push buttons that operate either full or reduced flush. The valve reduced flush assembly is adjustable to give different flush volumes. The valve incorporates an internal overflow (overflow can be fitted or blanked off). Cold water use only.
Dual flush drop valve with ABS body and silicone seal. The valve is operated via a lever assembly for either full or reduced flush and incorporates an internal overflow. Cold water use only.
Range of heat exchangers connected to copper waste pipe, Where the waste is discharged down a “rotator” into a copper waste pipe, and potable water is returned to the shower/heating device via a copper double walled jacket around the copper waste pipe. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C
Range of electric instantaneous water heaters. The DEX and DCX models incorporate a spherical ball valve on the inlet. The CEX and DEX models incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet incorporates a strainer. Maximum working pressure 10 bar (DEX models only) All other models open outlet. Maximum operating temperature: ES3/4/5 and Zip Hydrotap G4/G5 ranges – 65ºC. CEX, DEX and DCX ranges - 70°C.
Range of wall mounted, gas-fired, condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and a pressure relief valve set at 3.0 bar. The inlets to the domestic hot water and primary circuits each have a screwdriver operated angled spherical valve. Both include a ½” BSP (M) connection for a filling link. The Greenstar CDi models only are supplied with an integral charging link (CAB device) verified by test (suitable for backflow protection against Fluid Category 3). Maximum working pressure of the primary circuit is 2.5 bar. Maximum working pressure of the secondary circuit is 10.0 bar. Maximum operating temperature of primary circuit is 82°C. Maximum operating temperature of secondary circuit is 60°C.
Range of electric combination boilers providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar). The DHW inlet and outlet incorporate spherical servicing valves. Fittited with a CAB device keyless filling link, verifired by test, suitable for category 3 backlfow protection. Maximum working pressure on central heating circuit 2.5 bar & Domestic Hot Water 10bar. Maximum operating temperature 80°C
Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.
Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.
Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.
Range of wall hung, gas fired, combination boilers providing domestic hot water via a plate heat exchanger. The primary circuit incorporates an integral expansion vessel and a pressure relief valve set at 3.0 bar. The product is supplied with a rigid pipe filling loop, followed by a separate isolation valve. The filling loop pipe attaches to the cold water inlet valve which incorporates a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3) on the branch to the filling loop. The primary circuit includes an isolation valve on the flow and return and is also supplied with two loose 22mm compression isolation valves and a filter. Maximum working pressure of the primary circuit is 2.5 bar and the maximum supply pressure to the secondary circuit is 10.0 bar. Max operating temperature 65°C.
Hydraulic block assembly comprising of a flow regulator, central heating pump assembly and a stainless-steel plate heat exchanger. Maximum working pressures: DHW circuit: 10.0 Bar Central heating circuit: 2.5 Bar Maximum operating temperature: DHW Circuit: 65.0°C Central heating circuit: 90.0°C
Hydraulic block incorporating heat exchangers with pressed stainless-steel plate bodies and copper brazing. Product also incorporates primary and secondary water way with PPS plastic fittings and adaptors and a flow adjustment valve. Maximum operating temperature: Central Heating Circuit: 90°C, Direct Hot Water Circuit: 65°C. Maximum working pressure: Central Heating Circuit: 2.5 bar, Direct Hot Water Circuit: 10 bar.
Range of static ultrasonic bulk water meters with stainless steel bodies and EPDM 'O'-rings. The products are supplied with two sets of optional (green) gaskets. Maximum operating temperature: Products marked T50: 65°C. Products marked T30: cold water use only.
Permanent filling/ pressurisation device for primary heating and chilled water closed circuits in domestic and non-domestic premises. The mains and closed circuit system pressures are continuously checked by two pressure sensors and their differential monitored by microprocessors. In the event of a fall in system pressure, and only if the mains pressure is adequate, a solenoid valve operates to allow water into the system. At all other times a second solenoid valve drains the fill chamber to waste, via tundish (meeting the requirements of an air gap to drain), and allowing air to be admitted via an automatic air vent to create an atmospheric disconnection across the transfer chamber. Maximum working pressure 6.0 Bar. Cold water use only.
Permanent filling/ pressurisation device for primary heating and chilled water closed circuits in domestic and non-domestic premises. The mains and closed circuit system pressures are continuously checked by two pressure sensors and their differential monitored by microprocessors. In the event of a fall in system pressure, and only if the mains pressure is adequate, a solenoid valve operates to allow water into the system. At all other times a second solenoid valve drains the fill chamber to waste, via tundish (meeting the requirements of an air gap to drain), and allowing air to be admitted via an automatic air vent to create an atmospheric disconnection across the transfer chamber. Maximum working pressure 6.0 Bar. Cold water use only.
Range of shower handsets and shower heads. The shower handsets have a plastic body (white), NBR ‘O’-rings, and a coloured locking ring around the shower face (see model section). The shower heads have a plastic body (white or chrome plated 02-093173 model), NBR ‘O’-rings, directional adjustment (ball joint) and a coloured interlocking ring either surrounding or central to the shower face (except for the 02-093165 and 02-093173 models which have no ring). The Wall shower T-L models have a combined NBR washer and stainless steel strainer on the inlet.
Range of shower columns with an integral brass body and an aluminium painted column with chrome plated upper. Flow is controlled by a solenoid valve activated by an infrared sensor. The shower head inlet incorporates a combined NBR washer and stainless steel filter. The shower outlet incorporates a plastic flow regulator. The product is supplied with an inline ½” BSP (M) x ¾” BSP (F) screwdriver operated spherical valve with chromium plated brass bodies and ball for installation on the inlet. The product drains down after each use via an integral LLDPE tube leading to a drain outlet at the base of the column. Maximum working pressure 8.0 bar. Cold water use only.
Range of drain taps incorporating brass bodies, EPDM seats and washers and a non-rising spindle headwork. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of drain taps incorporating brass bodies, EPDM seats and washers and a non-rising spindle headwork. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Spherical valve with a brass body and ball, PTFE seat, EPDM ‘O’-rings, a lever operating member and a drain connection outlet. Compression end connection for use with copper pipe (manufactured to BS EN 1057). The product is supplied with a brass cap and an EPDM washer which is interchangeable with the hose union spigot outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Page 17 of 48
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.