Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes), incorporating ceramic cartridge headworks with single lever operating members. The spout outlet incorporates plastic flow straighteners. The products are supplied with a 15x15mm compression single check valve assembly (suitable for backflow protection against Fluid Category 2) which also incorporates an isolation valve, intended for installation at each inlet. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C
Range of two hole, single outlet (fixed) combination tap assemblies (chromium plated or matt black finished brass), incorporating quarter turn ceramic disc headwork with single lever operating members. The spout outlets of models 62315-5001, 62901-5001, 62907-5001 incorporate a plastic flow straightener. The inlet of model 62913-5001 incorporates a plastic flow restrictor. The products are supplied with metal backnuts. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet fixed combination tap assemblies (chromium plated brass), incorporating a single sequential thermostatic cartridge controlling both flow and temperature with a single lever operating member. The spout outlets incorporate a plastic flow straightener The inlets incorporate a concentric isolation valve, stainless steel strainer and a plastic flow regulator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Two hole, single outlet fixed combination tap assembly (chromium plated brass), incorporating a single sequential thermostatic cartridge controlling both flow and temperature with a single lever operating member. The spout outlet incorporates a plastic aerator. The inlets incorporate a stainless steel strainer and a plastic flow regulator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of wall mounted two-hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes). Incorporating a ceramic cartridge headwork with dome type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure; 10 Bar Maximum operating temperature 65°C
Wall mounted two-hole, single outlet (fixed) combination tap assemblies with brass bodies (chromium plated), incorporating a ceramic cartridge headworks and single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure: 5 bar. Maximum operating temperature: 60°C
Range of two hole, deck mounted, single outlet fixed combination tap assemblies incorporating quarter turn ceramic disc headworks with single lever operating members. Models XB-SL-046 and 079 incorporate plastic aerators, models XB-SL-049, 051 and 053 incorporate plastic flow straighteners. The products are supplied with metal back nuts. Maximum working pressure 10.0 bar. Maximum operating temperature for XB-SL-038 85oC, all other models are 65⁰C.
Range of wall mounted or floor standing spout outlets (fixed or swivel - see model in various finishes). All models incorporate a plastic flow straightener, except for the 93-Floor Mounted Bath Filler which has a plastic aerator.
Non-metallic materials and components comply with BS6920 at 60°C
Range of deck mounted spout outlets (fixed or swivel - see model, Various finishes) incorporating a plastic flow straightener. The products are supplied with metal backnuts.
Non-metallic materials and components comply with BS6920 at 60°C
Mini shock arrestor with a stainless steel body. Maximum working pressure 15.0 bar . Maximum operating temperature 70°C.
Range of expansion vessels with white epoxy coated steel bodies and butyl diaphragm. Please refer to model for maximum working pressures. Maximum operating temperature 70°C. Maximum working pressure 10.0 bar (all except two models), 8.0 bar (24749 & 24809 only).
Range of fohn stainless steel (SUS304/316L) crimp fittings incorporating EPDM ‘O’-rings. For use with FOHN stainless steel pipes (SUS304/316L). Maximum working pressure 16.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of copper press fittings (‘M’ type crimp profile) and brass threaded adaptor fittings, for use with copper pipe (EN1057). Maximum operating pressure - 16 bar @ 30°C and 10 bar @ 95°C.
Range of press copper crimp fittings with EPDM ‘O’-rings for use with copper tube manufactured to EN 1057. The joints are achieved by means of a crimping tool. For above ground use. Maximum working pressure: 16.0 bar. Maximum operating temperature: 85°C
TP range of capillary solder ring copper fittings for use with copper tube EN1057, for above ground use only. Maximum working pressure: 25.0 bar. Maximum operating temperature: 85°C.
Range of plastic compression fittings incorporating polypropylene bodies& plastic pipe liners.. For use with both PE80 & PE100 pipe manufactured to BS EN 12201. Maximum working pressure 16 Bar Maximum operating temperature 23°C
Range of ‘B’ Press XL copper crimped fittings with EPDM ‘O’-rings for use with copper pipe to BS EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of copper crimped fittings with EPDM ‘O’-rings for use with copper pipe manufactured to EN1057. For above and below ground use. Maximum working pressure 16 Bar. Maximum operating temperature 99°C.
B Profile range of 316L & 304 stainless steel press fittings with EPDM ‘O’-rings for use with stainless steel pipe manufactured to EN 10312, for both above and underground use. Joints are achieved by the use of a press fitting tool. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C.
Range of R-154 stainless steel pressed collars incorporating stainless steel bodies (304L or 316L) and are only to be used with stainless steel pipe. Maximum working pressure for sizes up to DN150 (FCM models) or DN125 (FCI models) is 25.0 bar. Maximum working pressure for size DN200 (FCM models) or DN150 and DN200 (FCI models) is 16.0 bar. Maximum operating temperature 99°C.
Page 157 of 207
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.