Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 6.0 bar at 95˚C and an expansion relief valve set at 4.5 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Supplied with an expansion vessel and tundish. Maximum working pressures: Secondary circuit: 4.0 Bar Primary Circuit: 3.0 Bar Solar circuit: 6.0 Bar Maximum operating temperature 99.0°C
Range of Compress 5800i AW vertical cased and insulated indirect unvented stainless steel hot water storage cylinders fitted with a Caleffi 309508 CST temperature and pressure relief valve set at 10 bar & 90°C, and supplied with a Caleffi inlet control group consisting of in-line pressure reducing valve (set at 3.5 bar) and pressure relief valve (set at 6 bar) and incorporates an approved check valve cartridge (verified by test suitable for backflow protection against Fluid Category 2). The cyclinders also supplied with an 18L expansion vessel and Intatec filling loop assembley (FL12041510). Maximum working pressure 10 bar. Maximum operating temperature 80°C.
Range of T-type thermostatic blending valves with nickel plated brass bodies and EPDM ‘O’-rings. The inlet and outlet incorporate an approved check valve cartridge ((verified by test - suitable for backflow protection against fluid category 2). Models with compression ends are to be used with copper pipe EN1057. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of T-type thermostatic mixing valves with DZR brass bodies. Maximum working pressure 14.0 bar. Maximum operating temperature 100°C.
Range of T-type thermostatic mixing valves with brushed chrome plated DZR brass bodies. Each inlet incorporates a check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) and stainless-steel strainers. Compression connections are for use with copper pipe (manufactured to BS EN1057). Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Range of concealed thermostatic shower mixers (brass bodies - various finishes). The flow is controlled by a four-way manual diverter (3 on, 1 off positions) with single lever, cube type or dome type operating members. The temperature is controlled independently via a thermostatic cartridge incorporating a manual override button with single lever, cube type, dome type or cross top operating members. The inlets incorporate an approved check valve cartridge, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 Bar Maximum operating temperature 60.0°C
Range of T-type thermostatic mixing valves with DZR brass bodies. Temperature is pre-set under a fixed cap. The inlet adaptors incorporate single check valve cartridges (verified by test, suitable for backflow protection against Fluid Category 2) and stainless-steel strainers. Maximum working pressure 10.0 Bar. Maximum operating temperature 85.0°C.
Combined temperature and pressure relief valves pre-set at 7.0 bar with a DZR brass body. Maximum operating temperature 90°C.
Range of two-way manual diverter valves with shut-off position. Products are for insertion into specifically dimensioned bodies. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of concealed and exposed two-way diverters, (brass bodies – various finishes, trim sets and operating members). The inlets on XX1650YY and XX1721YY models incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 Bar. Maximum operating temperature 85°C (PSA019 YY, PSA020 YY & XX1782YY) Maximum operating temperature 60°C (PSH049, XX1650YY, RZ/1721 & XX1721YY).
Range of pre-set pressure relief valves incorporating DZR brass bodies and an EPDM diaphragms and PTFE washers. The valve is fitted with hand operated rotating easing gear. Maximum working – see model. Maximum operating temperature 85°C
Range of lever or butterfly operated spherical valves with brushed chromium plated brass bodies, chromium plated brass ball and PTFE seat. Maximum working pressure model K656: ¼” to ½” = 64.0 bar, ¾” to 1¼” = 50.0 bar, 1½” to 2” = 40.0 bar, 2½” to 4” = 25.0 bar. Model K6566 model: ¼” to ⅜” = 64.0 bar, ¾” to 1¼” = 50.0 bar, 1½” to 2” = 40.0 bar, 2½” to 4” = 25.0 bar. Models K8912 , K8913 & K6568 models: ¼” to ⅜” = 64.0 bar. Maximum operating temperature 99°C.
‘Instantor’ range of lever operated spherical valves with brass bodies and balls (chromium plated), incorporating PTFE seats, EPDM ‘o’ rings single lever handles (red or blue). For use with imperial Irish copper pipe (manufactured to IS EN 1057). Maximum working pressure 16 bar. Maximum operating temperature 85°C
Screw down stop valves with brass bodies and dome type operating members. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
STAD range of balancing valves with brass bodies, PTFE sliding washer and EPDM O-rings. Models are available with or without a drain port. Maximum working pressure 25.0 bar. Maximum operating temperature 100°C.
Range of in-line electrolytic scale reducers with copper bodies for use with copper pipe (manufactured to BS EN 1057). Maximum working pressure 10.0 bar. Maximum operating temperature 40°C.
‘NMSP2104 M & ER2104A01SM'. The following coatings were added to the approval in March 2025: ER2209A01SC, ER2252A01SC, ER2259A01SC & ER2260A01SC. Factory applied, blue coloured, porcelain (vitreous) enamel coatings. Apply as per manufacturer’s user manual 'PEM 38', edition '01' dated '14/10/2020'. Cure for 5 minutes@840°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'PRIMGREEN® ENDURANCE & Primgreen LAT 12035' primers for use with 'RILSAN® PA11 T BLUE 7444 MAC (16293), PA11 T GREY 5161 MAC (17203), PA11 T WHITE 1488 AC (17219) & PA11 T BLACK 7450 AC (17185)' coatings. Factory applied primers and powder coatings. The piece to be coated is to be pre-heated to 330°C for 10 minutes, the primer and coating applied in accordance with user instructions 'Dircom - 4418E/05.2015/20' and then cured for 10 minutes@330°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘NMSP2104 M'. Factory applied, blue coloured, porcelain (vitreous) enamel coatings. Apply as per manufacturer’s user manual ‘specification no. PIN-10’, revision no. '0' dated '15/10/2020'. Cure for 5 minutes@840°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Page 131 of 160
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.