'51M6630'. Black coloured, injection moulded EPDM material. Shore hardness 70A. Tested in-radius size 1.0mm. For use with water up to 70°C.
‘Permabond A011 Red, A025 Orange, A113 Blue, A115 Orange, A118 Green, A130 Blue, A131 White, A134 Green, A136 Red, A140 Green, A1042 Blue, A1044 White, A1058 Off White, F200 Brown, F201 Brown, F202 Brown, A1084 Yellow & F201HV (translucent)’. Anaerobic adhesives to be applied and cured in strict accordance with the manufacturer's instructions. For use with water up to 85°C.
'RIAMAXX HR XE4355 KTW-M schwarz & RIAMAXX HR XE4355 KTW-M sondergrau K 7-140‘. Black or grey coloured, injection moulded PK materials. For use with water up to 60°C.
'Butyl IIR 6038 diaphragm'. Black coloured, injection moulded Butyl diaphragm. Shore hardness 64 ShA. Tested in-radius size 1.25mm. For use with water up to 85°C.
Range of electronic combination tap assemblies, incorporating a solenoid valve controlling the flow that is activated via an infra-red sensor. The Xeris models (012930699 & 012940699) incorporate a check valve cartridge in the inlet hose, however the complete assembly has not been tested to demonstrate it provides backflow protection. Maximum working pressure 10 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet swivel nozzle combination tap assemblies (brass bodies - various finishes) incorporating quarter turn ceramic disc headworks with cross top operating members. The outlet incorporates a plastic aerator and the product is supplied with a lever type pop-up waste, not verified by test. Maximum working pressure 10.0 Bar Maximum operating temperature 65.0°C
Range of single hole bidet combination tap assemblies (brass bodies - various finishes) incorporating a ceramic cartridge headwork and single lever operating member. The swivel nozzle outlet incorporates a plastic aerator and the product is supplied with a lever type pop-up waste – not verified by test. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.
Range of flow regulators, aerators and flow straighteners with plastic bodies. Maximum operating temperature 60°C.
Range of flow straighteners with plastic bodies. The JM030503-15 model incorporates a silicone lined flexible hose with an interlocked metal outer. The JM030002-15 model incorporates a swivel ball joint. Both models incorporate a stainless steel mesh on the outlet. Maximum operating temperature 60°C.
Range of balancing valves with DZR brass bodies Maximum operating pressure 25 bar. Maximum operating temperature 99°C
Ceramic cartridge headwork with a plastic body. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of ceramic cartridge headworks with plastic bodies. For insertion into specifically dimensioned tap assemblies. Maximum working pressure 10.0 bar. Maximum operating temperatures 85°C (K26PMA-01NP model) and 65°C (K40P-01NPX model).
Range of ceramic cartridge headworks with plastic bodies for insertion into specifically dimensioned tap assemblies. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of single-hole, single outlet (swivel) combination tap assemblies (chrome plated brass bodies). Incorporating ceramic cartridge headworks and single lever operating members. The flexible spout outlet incorporates a plastic aerator and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (fixed) combination tap assembly (brass bodies – various finishes). Incorporating quarter turn ceramic disc headworks with single lever operating members. The spout is a pullout hose and handset with an optional spray function. The outlet incorporates a plastic aerator. Maximum working pressure 10.0 Bar Maximum operating temperature 65.0°C
Single-hole, single outlet (swivel) combination tap assemblies (brass body – various finishes) incorporating a ceramic cartridge (MARTA CH) or quarter turn ceramic disc (ALTUS CH) headwork with a single lever operating member. The products have a pull-out spray outlet which incorporates a plastic aerator and trigger mechanism that stops the flow (model (ALTUS CH) or changes the water pattern from straight flow to spray (MARTA CH). Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a pull-down spray with a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies (brass body – various finishes), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet is a pull-out spray type. Maximum working pressure 10.0 Bar. Maximum operating temperature 65.0°C.
Single hole, single outlet fixed combination tap assembly (chrome plated brass body), incorporating non-rising spindle headworks with dome type operating members. The spout outlet incorporates a plastic flow straightener. Maximum operating pressure 10.0 bar. Maximum operating temperature 65°C.
Single hole, single outlet, fixed combination tap assembly (chrome plated brass body), incorporating quarter turn ceramic disc headworks with single operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with a lever operated pop-up waste (not verified by test) Maximum operating pressure 10.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (fixed) combination tap assemblies, (brass bodies – various finishes). Incorporating a ceramic cartridge headworks with single lever operating members. The spout outlets incorporate plastic aerators. Maximum working pressure 5.0 Bar Maximum operating temperature 60.0°C
Range of single hole, single outlet (fixed) combination tap assemblies with (brass bodies - various finishes), incorporating ceramic cartridge headworks and dome type operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure; 5 Bar Maximum operating temperature 65°C
Single hole, single outlet (fixed) combination tap assemblies (chrome plated brass body) incorporating a ceramic cartridge headwork with various operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of floor-standing single hole, single outlet (fixed) combination tap assemblies (various finishes), incorporating a ceramic cartridge headworks with single lever operating members and a self-cancelling diverter to shower outlet. The spout outlet incorporates a plastic aerator. The product is supplied with shower hose and handset. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C
Range of floor mounted single hole, single outlet (fixed), combination tap assembly (various plated brass), incorporating a ceramic cartridge headwork with a single lever operating member and a manual diverter to shower outlet with a dome type operating member. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies – various finishes). Incorporating a ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.5 bar. Maximum operating temperature 60°C
Range of single-hole, single outlet (swivel) combination tap assemblies (brass bodies – various finishes) incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate plastic aerators. The product is supplied with 3/8” x 15mm reducers incorporating approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Product is to be used with an instantaneous water heater. Maximum working pressure: 10.0 bar Maximum operating temperature: 60°C
Range of single-hole, single outlet (swivel) combination tap assemblies (brass bodies – various finishes) incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate plastic aerators. Products incorporate an additional hose outlet and shut-off valve for use with an external domestic appliance. Maximum working pressure: 10.0 bar Maximum operating temperature: 60°C
Range of single-hole, single outlet (swivel) combination tap assemblies (brass bodies – various finishes) incorporating ceramic cartridge headworks with single lever operating members. The spout outlets incorporate plastic aerators. Maximum working pressure: 10.0 bar Maximum operating temperature: 60°C
Range of single hole, single outlet (swivel) combination tap assemblies (brass bodies - various finishes), incorporating quarter turn ceramic disc headworks with single lever operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The inlet hoses for models APL1 & ATE1 incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.





Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The inlet hoses incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork and single lever operating member. The pull-out spout outlet incorporates a plastic aerator and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The inlet hoses for models Aquaplay single lever Aquanomic & Aquatech single lever Aquanomic incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork and single lever operating member. The spout outlet incorporates a plastic aerator. The cold inlet hose and the spout outlet incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, single outlet (swivel) combination tap assembly (chromium plated brass), incorporating a ceramic cartridge headwork and single lever operating member. The pull-out spout outlet incorporates a plastic aerator and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The inlet hoses incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlet incorporates a plastic aerator. The cold only inlet hoses incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, double outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and dome operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Single hole, double outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic disc headworks and dome operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted two hole, single outlet (fixed) combination tap assembly (brass body, various finishes), incorporating ceramic cartridge headwork and single lever operating member. The spout incorporates a plastic aerator. Maximum working pressure: 5.0 bar. Maximum operating temperature: 60°C.
Range of wall mounted two-hole, single outlet (fixed) combination tap assemblies (brass bodies with various finishes) incorporating a ceramic cartridge headwork with single lever operating member. The spout outlets incorporate an aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted two-hole, single outlet (fixed) combination tap assemblies (brass bodies - various finishes). Incorporating a ceramic cartridge headwork with dome type operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure; 10 Bar Maximum operating temperature 65°C
Range of two-hole, double outlet (swivel) combination tap assemblies (chromium plated brass), incorporating quarter turn ceramic discs headworks and single lever or dome operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of wall mounted three-hole, single outlet (fixed) combination tap assemblies with brass bodies (various finishes). Incorporating quarter turn ceramic disc headworks and various operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 3.5 bar. Maximum operating temperature 60°C
Range of tap adaptors with chrome plated (brass or plastic) bodies. The outlet of some models incorporates a plastic flow restrictor. The side mount adaptors (except 90-001801) incorporate an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The side mount adaptors (except 90-001804) incorporate a piston type component which is intended to stop the flow to change the filter. All side mount adaptors and 90-001869 & 90-001873 Fixed Position Adaptors have a maximum working pressure of 5.0 bar. All other models are open outlet use only. Maximum operating temperature 60°C.
Range of exposed bath fillers (brass body, various finishes) incorporating a ceramic cartridge headwork, controlling both flow and temperature with a single lever operating member. The products incorporate integrated overflow and click type pop-up waste systems. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C
Range of expansion vessels with fibreglass bodies and butyl diaphragms. Maximum working pressure: 8.6 Bar. Maximum operating temperature: 23 °C.
SuperFlow MCPA, MCMA & MCUA ranges of expansion vessels. Maximum working pressures: MCPA Series = 10.0 bar, MCMA Series = 16.0 bar, MCUA Series = 25.0 bar. Maximum operating temperature 65°C.
Page 123 of 177
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.