Range of under counter, vented, electric instantaneous (near boiling) water heaters with a stainless steel tank and silicone seals. Maximum operating temperature 98°C.
SATK Series 22 range of wall-mounted direct heat interface units providing heating and instantaneous hot water. The hot water is generated via a plate heat exchanger. Maximum working pressure of all water circuits (secondary hot water, primary and space heating) 10.0 bar. Maximum operating temperature 90°C.
Range of wall mounted combination boilers providing domestic hot water via a heat exchanger and pressurised central heating system. The products can be supplied with a rigid or flexible filling loop or keyless filling link. The flexible and rigid filling loops incorporate a flexible hose or copper pipe, isolation valve, double check valve assembly (suitable for back flow protection against fluid category 3). The keyless filling link incorporates a CAB backflow prevention device (suitable for back flow protection against fluid category 3). The products also incorporate an expansion vessel and pressure relief valve set at 3.0 bar. Maximum working pressure of primary circuit 2.5 bar. Maximum operating temperature of primary circuit 85°C Maximum working pressure of secondary circuit 8.0 bar Maximum operating temperature of secondary circuit 60°C
‘SATK 32’ range of indirect heat interface units providing instantaneous hot water. Domestic hot water is provided via a plate heat exchanger and this circuit incorporates a flow detector, stainless-steel filter and water hammer arrestor. The primary/space heating circuit incorporates a pressure relief valve set at 2.5 bar and an expansion vessel. Maximum working pressure of the domestic hot water circuit is 10.0 bar. Maximum working pressure of the primary circuit is 16.0 bar. Maximum working pressure of the space heating circuit is 2.5 bar. Maximum operating temperature 90°C.
Non-metallic materials and components comply with BS6920 at 85°C
Magnetic non-return valve with a brass body and EPDM seals. Maximum working pressure 16.0 Bar. Cold water use only.
Range of pressure transmitters with stainless steel bodies. Maximum working pressures: Press.Tr.ISP40 model 25.0 bar, all other models 50.0 bar. Maximum operating temperature 90°C.
Range of circulating pumps with a bronze body, plastic impeller and EPDM gaskets. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Range of shower outlets having plastic bodies, various finishes Maximum operating temperature 55°C
Range of shower outlet with plastic bodies (chromium plated) and plastic flow regulators. Model 27.369 supplied with a PVC multi-layered shower hose with EPDM washer and plastic strainer on inlet. Maximum working temperature 60°C.
‘Grohe Euphoria 180’ overhead shower outlet with a chromium plated brass body incorporating a plastic flow regulator. Maximum working temperature 60°C.
Range of shower handsets with (plastic bodies - various finishes). The inlets incorporate a plastic flow restrictor. Maximum operating temperature 60.0°C Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower outlets with brass bodies (various finishes). The products incorporate a stainless-steel strainer and flow regulator. Open outlet use.
Range of flow sensors with brass or plastic bodies (see model). Maximum working pressure 16.0 bar. Maximum operating temperature 90°C.
Range of pillar taps with brass bodies, (various finishes - see model), incorporating quarter turn ceramic disc headworks with cross top or single lever operating members (see model). The spout outlet of the F5117** model incorporates a plastic aerator. The spout outlet of the F5197**, F6007**, F6008** & F6117C** models incorporates a plastic flow straightener. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of pillar taps with brass bodies, (various finishes - see model), incorporating quarter turn ceramic disc headworks with cross top or single lever operating members (see model). The spout outlet of the F5198** & F6118C** models incorporates a plastic flow straightener. The products are supplied with metal backnuts. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of pillar taps (chromium plated brass) incorporating quarter turn ceramic disc headworks and single lever operating members. The spout outlets incorporate plastic aerators (except 2.1977.005 that has flow restrictor) and the products are supplied with plastic backnuts. Maximum operating pressure 5 bar. Maximum operating temperature 60°C
Non-metallic materials and components comply with BS6920 at 60°C
Range of nylon braided hoses with TPSiV inner liner and brass end connections incorporating EPDM washers.Open outlet use only.
Non-metallic materials and components comply with BS6920 at 65°C
Range of concealed, wall mounted, thermostatic blending valves, (brass bodies, chrome trim sets). The products consist of detent headworks, two-way diverter cartridges and a thermostatic cartridges (see models). All models incorporate approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of T type thermostatic blending valves incorporating stainless steel strainers at the inlet. “2 IN 1” models incorporate check valve cartridges at both inlets. “4 IN 1” models have angled isolation valves at both inlets which incorporate a check valve cartridge verified by test (suitable for backflow protection against Fluid Category 2). Maximum working pressure 16.0 bar
Non-metallic materials and components comply with BS6920 at 85°C
T-type thermostatic blending valve with a brushed chrome, DZR brass body. Temperature is pre-set under a fixed cap. The inlets incorporate stainless steel strainers and single check valve cartridges, verified by test (suitable for backflow protection against Fluid Category 2). For use with copper pipe (manufactured to BS EN 1057). Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Page 122 of 201
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.