Single hole, single outlet (swivel) comination tap assembly (chromium plated brass). Incorporation a ceramic disc headwork with dome type operating members. The spout outlets incorporate a metal strainer and either a plastic aerator or alternative flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Single hole, single outlet (swivel) comination tap assembly (chromium plated brass), incorporation a non-rising spindleheadwork with crosstop type operating members. The spout outlets incorporate a metal strainer and either a plastic aerator or alternative flow straightener. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of single hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating ceramic cartridge headworks and single lever operating members. The spout outlet incorporates a plastic aerator. Maximum working pressure 6.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (swivel) combination tap assemblies with brass bodies (various finishes), incorporating ceramic cartridge headworks and single lever operating members. The spout outlets incorporate a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of single-hole, single outlet, (swivel) combination tap assemblies with brass bodies (various finishes), incorporating quarter turn ceramic cartridge headworks with single lever operating members. The spout outlets incorporate a plastic aerator and the inlets incorporate a stainless-steel strainer. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, concealed two-hole, single outlet (fixed) combination tap assemblies (brass bodies, various finishes) incorporating ceramic cartridge headwork with single lever operating members. The spout outlets incorporate a plastic aerator, some also incorporate a flow regulator. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C
Range of five hole, single outlet (swivel) combination tap assemblies (chromium plated brass). Incorporating a ceramic cartridge headwork controlling the flow to the shower handset and two quarter turn ceramic disc headworks controlling the flow to the spout outlet, all with single lever operating members. The spout outlets incorporate a plastic aerator. The inlet to the shower handsets incorporate an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with a shower hose and handset. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of Aquaterra PP-RCT socket fusion fittings for use with Aquaterra PP-RCT SDR 6 pipe and Aquaterra PP-RCT SDR 7.4 pipe (manufactured to EN ISO 15874). Maximum working pressure 10.0 bar. Maximum working temperature 85°C.
Viega ‘Raxofix’ press connection fittings for use with viega Raxofix PE-Xc/Al/PE-Xc pipes. For above ground use only. Maximum working pressure 10 bar. Maximum operating temperature 70°C
Viega ‘Raxofix’ press connection fittings for use with viega Raxofix PE-RT/Al/PE-RT pipes. For above ground use only. Maximum working pressure 10.0 bar. Maximum operating temperature 70°C
‘Numepress’ range of stainless-steel crimp fittings incorporating EPDM and ‘O’-rings. For use with stainless steel tube. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.
‘Epsilon Series’ polypropylene bodied compression fittings with EPDM ‘O’-rings for use with Elysee PE80 blue pipes. The fittings are supplied with a pipe liner. Above and below ground use. Maximum working pressure 12.5 bar. Cold water use only.
‘ISR’ range of copper, DZR brass or gunmetal capillary, lead free solder ring and threaded fittings for use with copper pipe. For above ground use only. Maximum working pressure 16.0 bar. Maximum working temperatures 99°C.
Range of copper and bronze capillary brazed fittings for use with copper pipe manufactured to EN1057:2006 +A1:2010. Maximum pressure 10.0 Bar (54mm up to and including 108mm) Maximum pressure 2.0 Bar (Over 108mm up to and including 159mm) Maximum operating temperature 100°C.
Range of brass compression fittings for use with copper pipe to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.
Range of press fittings incorporating copper or copper alloy bodies and EPDM O’-rings for use with copper tube to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Uponor Combi Port range of indirect heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar).Some units have optional ball valve sets. Primary side heating 85°C and 2.5 bar. Secondary side, space heating 60°C and 2.5 bar. Secondary side DHW 60°C and 4.0 bar.
Range of indirect heat interface units with copper brazed stainless-steel heat exchangers, providing heating and instantaneous hot water. The products incorporate an expansion vessel on the cold-water supply to the plate heat exchanger and a safety relief valve on the space heating circuit set @ 3.0 bar. The domestic hot water and space heating circuit are both fitted with drain valves incorporating cover caps. Maximum working pressures: Domestic hot water 10.0 bar. Space Heating 2.5 bar. District Heating 3.0 bar. Maximum operating temperature 85˚C.
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. Incorporating a pressure relief valve and expansion vessel. Primary circuit has a maximum working pressure of 3.5 bar and operating temperature of 85°C. Secondary circuit has a maximum working pressure of 10.0 bar and operating temperature of 60°C.
Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system, incorporating a pressure relief valve set at 3.0 bar and expansion vessel on the primary circuit. The inlet of the replenishing valve between the primary and secondary circuits incorporate a plastic strainer. Maximum working pressure 2.5 bar (primary) and 6.0 bar (secondary). Maximum operating temperature 85˚C.
Page 113 of 176
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.